Air conditioning service check sheet
-
Store details
-
Air-conditioning Equipment serviced
Air conditioning system
-
Make of air conditioner and specify type of unit
-
Model of air conditioner
-
Serial No
Compressors technical information
-
Compressor information
-
Are all the compressor free of any abnormal noise or vibration
-
Are the crank case heaters working ?
-
Are the oil levels correct
Record gas pressures
-
Was the unit checked for any visible signs of gas leaks
Compressor efficiency test
-
Compressor No
-
Does the low side suction pull & hold the vacuum?
-
Does the head pressure equalize with the suction pressure?
Are all the super heat temperatures within the design parameters?
Safety switches check list
-
HP/LP pressure test
-
Record oil pressure switch details
-
Are the unloaders working
-
Are all the pressure and safety switch covers fitted back on the switches
-
Has the timer been checked
-
Has the flow switches been checked
Supply air fan motors
-
Are the units free of any abnormal noises and vibrations
-
Has the fan belts been checked
-
Are there spare fan belts on site
-
Has the evaporator coils been checked
-
Photo required
-
Has the condenser coils been checked and cleaned
-
Photo required
-
Are all the fan motors and water pumps operational
Electrical technical information
-
Electrical panels
-
Has the electrical panel and pilot lights been checked
-
Are the electrical boards cool
-
Has all the electrical terminals been checked for loose connections
-
Has the electrical overloads been checked for the correct amperage setting
-
Has the electrical panel been blown out
Air conditioning plant rooms
-
Plant rooms
-
Was the temperature controllers set point check
-
Are the the plant room lights working
-
Has the plant room been cleaned
-
Are all the plant rooms are clean and free of obstructions
-
Photo required
-
Has all the drains in the plant room been checked
-
Are the filters in a good condition
-
Has all the covers been fitted back on the units
-
Photo required
Cooling tower information
-
Cooling Tower
Cooling tower
-
Make and type
-
Model No
-
Serial No
-
Was the ball valve operation checked to maintain the correct water level in the sump
-
Was the stainer checked in the sump
-
Are all the motors and pumps working
-
Is the cooling tower free of scale
-
Is there water treatment for the cooling tower
-
Has the cooling tower chemicals been checked
-
Are all the eliminators in good condition
Air conditioning check list in the store
-
Has all the set points on the temperature controllers been checked
Server room air conditioner
-
Make
-
Model
-
Serial No
-
Photo required
-
General feel of air temperature and humidity in the store is comfortable
-
Are all the indoor units are in good working order and clean
-
Are all the indoor equipment is mechanically sound
-
Are all the fan motors are working without any visible or audible concerns
-
Are all the return and supply air grills are clean
-
Are all the exposed ducting is cleaned and sealed, with no signs of condensation
-
Are all the drains are in good order
-
Photo required
-
Are all the extractors are in good work condition
-
Are all the general ventilated areas are well vented
-
Are all the extraction grills are clean and clear of obstructions
-
Are all the services are up to date
Sign Off
-
Technician name and signature
-
Technician assistant and additional help if required
-
Comments
-
Store managers signature