Title Page
-
FDIS REF No: XR
-
Door Number:
-
Location:
-
Were you able to gain access to carry out the inspection?
- Inspection carried out
- Unable to gain access
- No answer at address
- Client refused inspection
-
Floor Location:
- Basement
- Lower Ground
- Ground Floor
- 1 Floor
- 2 Floor
- 3 Floor
- 4 Floor
- 5 Floor
- 6 Floor
- 7 Floor
- 8 Floor
- 9 Floor
- 10 Floor
- 11 Floor
- 12 Floor
- 13 Floor
- 14 Floor
- 15 Floor
- 16 Floor
- 17 Floor
- 18 Floor
- 19 Floor
- 20 Floor
- 21 Floor
- 22 Floor
-
Site conducted
-
Conducted on:
-
Prepared and Inspected by
All Measurements and Dimensions in MM.
JSS Detail of Inspection Sheet:
Door Frame:
-
DOOR FRAME: Is the door frame free from cracks, damage, breaks?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Composition of frame?
-
Frame Dimensions?
-
Door Stop Dimensions?
-
Architrave fitted and Dimensions ?
Door Leaf:
-
Door Composition ?
- Steel
- Fully Glazed Steel
- Timber Panel
- Timber Flush
- Timber Solid
- Composite
- Fully Glazed Timber
- Glazed Panel
- UPVC
- Aluminium
-
Door Dimensions?
-
Doorset Function?
- 1 & 1/2 Leaf Door Set
- Single Action
- Double Action
- Double Door Set
-
Is the door leaf in good condition and free of damage?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Glazing:
-
Is there Glazing if Yes Complete or No move to next component .
-
Type of Glazing used?
- Georgian Wired
- Double Glazed
- PyroGlass
- PyroGlaze
- NON FR Glazing
-
Glazing Dimensions?
-
Beading composition and dimensions?
-
Is there a intumescent gasket fitted?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Are all glazing, vision light frames and glazing, beads intact and securely fastened?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Door Gaps & Clearance:
-
Is the door threshold gap no more than 10mm?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Does the active door leaf completely close when operated from any position ?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Is the clearance from the door edge to the frame no more than 4mm?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Does the inactive leaf close before the active leaf when a coordinator is used?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
LOCKSET / LATCH:
-
Is Lock or Latch fitted?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Type of Lock?
- Lever Latch
- Cylinder
- Mortice
- Fob - Maglock
- Key Card
- Key Pad
- Banham Security Locks
- N/A
-
Dimensions?
-
Non Standard Dimensions (if required)
Door Closure:
-
Type of Closure?
- OHDC
- Dorma-Kaba
- Briton
- No Markings
- Perko concealed closure
- NOT FITTED
-
Any detailed information
-
Is the closure serviceable (Not Leaking or Damaged)?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Does the latching hardware operate and secure the door in the closed position?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Is there a holding open device?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Does the OHDC Bolt Need to be replaced?
- No
- Yes
- Missing
- N/A
Hinges / Pivot Hinges:
-
Description of Hinges?
- Steel
- Aluminium
- Brass
-
No of hinges?
- Two
- Three
- Four
- Both Doors
-
Dimensions of Hinges?
- 100 x 30
- 100 x 35
- 150 x 40
- Miscellaneous size please see notes
-
Any damage or screws missing?
- No
- Yes
- N/A
- Not Modified
-
Door Spring Fitted?
- Yes
- N/A
Panic Hardware:
-
Is there any fitted Panic bar if so, Make, Type ?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Push Bar Dimensions?
Fire Seals and Smoke Seals:
-
Type of seal fitted?
- Intumescent Seal
- Combination Smoke and Intumescent Seal
- Seal Missing
- NON FD Weather seal
- Not Installed
-
Size?
- 10mm Seal
- 15mm Seal
- 20mm Seal
- 25mm Seal
- 15mm Combination seal
- 20mm Combination Seal
- MISSING
-
Are all Intumescent seals in good working order and correct size?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Automatic Threshold Seal:
-
Is there a threshold seal fitted?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Door Hardware:
-
Are there any missing or broken parts from frame or leaf?
-
Door Handles / Push Plate / Kick Plate Correctly installed and dimensions recorded?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Is there a internal door chain fitted
-
Letterplate and dimensions?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Hardware Intumescent packing used?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Bolts and Air Grilles:
-
Is there Bolts fitted?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Type of Bolt?
-
Is there an Air Transfer Grille Fitted?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Astragal Stop - Edge Protector:
-
Astragal- Angle Stop- Edge Protector?
-
Are the items correct and dimensions taken?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
Overall Door standard:
-
All questions answered No must be fully explained in detail?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Is the door correctly signed?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Is the door hung correctly and is it free to move and close at all angels?
- Yes
- Not Modified
- No
- N/A
- Not Required
- Missing
-
Has the door been modified since it was originally installed?
- Yes
- No
- N/A
-
Wall interface condition?
-
Any other comments?
Door Status:
-
Does this door meet the standards of a Fire Door?
- Certificated
- Nominal / Notional
- Non Fire Rated Door
- Unserviceable
- Suitable Final Fire Exit or Escape Route
- Evidenced
-
Fire Rating:
- FD30
- FD30S
- FD60
- FD60S
- FD90
- FD120
- NON-FD
-
Door Function:
- Compartmentation
- Final Fire Exit
- Escape Route
- Non Fire Door
- External
- Internal
Fire Door Inspector Additional Information:
-
Details.