Title Page

  • FDIS REF No: XR

  • Door Number:

  • Location in Building:

  • Were you able to gain access to carry out the inspection?

  • Site conducted:

  • Conducted on:

  • Prepared and Inspected by

All Measurements and Dimensions in MM.

  • ALL MEASURMENTS ARE IN MM.

Savoy Building -INSPECTION REPORT

  • Door Location:

  • Fire Rating:

  • Door Function:

Inspection Activity Sheet:

Door Frame

  • DOOR FRAME: Is the door frame free from cracks, damage, breaks?

  • Composition of frame?

  • Frame Dimensions?

  • Door Stop Dimensions?

  • Architrave fitted and Dimensions ?

Door Leaf

  • Door Composition ?

  • Door Dimensions?

  • Doorset Function?

  • Is the door leaf in good condition and free of damage?

Glazing

  • Is there Glazing if Yes Complete or No move to next component .

  • Type of Glazing used?

  • Glazing Dimensions?

  • Beading composition and dimensions?

  • Is there a intumescent gasket fitted?

  • Are all glazing, vision light frames and glazing, beads intact and securely fastened?

Door Gaps & Clearance

  • Is the door threshold gap no more than 10mm?

  • Does the active door leaf completely close when operated from any position ?

  • Is the clearance from the door edge to the frame no more than 4mm?

  • Does the inactive leaf close before the active leaf when a coordinator is used?

LOCKSET / LATCH

  • Is Lock or Latch fitted?

  • Type of Lock?

  • Dimensions?

  • Non Standard Dimensions (if required)

Door Closure

  • Type of Closure?

  • Any detailed information

  • Is the closure serviceable (Not Leaking or Damaged)?

  • Does the latching hardware operate and secure the door in the closed position?

  • Is there a holding open device?

  • Does the OHDC Bolt Need to be replaced?

Hinges / Pivot Hinges

  • Description of Hinges?

  • No of hinges?

  • Dimensions of Hinges?

  • Any damage or screws missing?

Panic Hardware

  • Is there any fitted Panic bar if so, Make, Type ?

  • Push Bar Dimensions?

  • Make of Hardware:

Fire Seals and Smoke Seals

  • Type of seal fitted?

  • Size?

  • Are all Intumescent seals in good working order and correct size?

Automatic Threshold Seal

  • Is there a threshold seal fitted?

Door Hardware

  • Are there any missing or broken parts from frame or leaf?

  • Door Handles / Push Plate / Kick Plate Correctly installed and dimensions recorded?

  • Is there a internal door chain fitted

  • Letterplate and dimensions?

  • Hardware Intumescent packing used?

Bolts and Air Grilles

  • Is there Bolts fitted?

  • Type of Bolt?

  • Is there an Air Transfer Grille Fitted?

Door spring - Astragal Stop - Edge Protector

  • Astragal- Angle Stop- Edge Protector?

  • Are the items correct and dimensions taken?

Overall Door standard

  • All questions answered No must be fully explained in detail?

  • Is the door correctly signed?

  • Is the door hung correctly and is it free to move and close at all angels?

  • Has the door been modified since it was originally installed?

  • Wall interface condition?

  • Any other comments?

Door Status

  • Does this door meet the standards of a Fire Door?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.