Inverters/AC Distribution
-
Are the Inverters operating according to the manufacturer's specifications?
-
Please describe the fault and attach image(s) where appropriate
-
Do the Inverters show any indication of overheating, noise or vibrations?
-
Please describe the fault and attach image(s) where appropriate
-
Check wiring and connection of parts using infra-red technology and report any defects here. Attach images where appropriate.
-
Are all covers and door locks in good condition according to the manufacturers specifications?
-
Please describe the condition and attach image(s) where appropriate
-
Is the humidity level in the AC cabinet acceptable?
-
Please describe the condition and attach image(s) where appropriate
-
Check and clean a 10% sample of the cooling parts (fans or radiators depending on the inverter) according to the manufacturers specifcations - note which inverters were cleaned
-
Inverters Cleaned:
-
Did any of the inverter's cooling parts show signs of damage or malfunction?
-
Please describe the damage and note the inverter number. Attach image(s) if possible.
-
Carry out thermographic inspections of a sample of 10% of the AC connections.
-
Were any defects detected?
-
Please describe the defects and attach image(s) where possible
-
Carry out a 10% sample check of electrical connections and connectors. Connectors should be checked, electrically tested and inspected for signs of over-heating or corrosion. Any coupling should be tightened according to the applicable torque rating as specified by the manufacturer.
-
Do any of the checked connections show signs of overheating or corrosion?
-
Please describe the condition and attach image(s) where possible
-
Check that there is no sign of damage by animals to a sample of 10% of the component parts.
-
Did any checked components show signs of damage caused by animals?
-
Please describe the damage, note the component's location and attach image(s) where appropriate
-
Is there any smell of burning or evidence of overheating from the AC equipment?
-
Please note which inverter the smell appears to be coming from
-
Clean the inverter room and cabinets
Mains AC Connection to the PV System
-
Check that a 10% sample of indicators, meters and instruments are functioning properly and do not present undue noise, vibration or abnormal smell. If applicable check resistors.
-
Were all components functioning correctly and not presenting any of the listed concerns?
-
Please note malfunctioning components and attached images where appropriate.
PV Generator
-
Visually assess the soiling and shading of the panels
-
Please note any shading concerns or excessive soiling its source (if determined), attached images where appropriate
-
Visually check that a sample of 10% of the panels are securely retained in the mounting system structure
-
Were all panels checked securely retained?
-
Please note the panels location, and attach images of the issue
-
Check and test a 10% sample of the DC connectors (DC string combiner box and both serial and parallel connections)
-
Did any of the DC connectors present reason for concern?
-
Please describe the concern and attached images where appropriate
-
Check the solar cables for damage, fixings and containment
-
Were any of the solar cables or their fixings & containment damaged?
-
Please describe the damage, note the location and attached images where appropriate
-
Do any of the panels show signs of mechanical damage or abnormal discolouring?
-
Please describe the condition, note the location and attached images where appropriate
-
Carry out thermographic imaging of a 10% sample of strings
-
Were any defects detected?
-
Please describe the defect, note the location and attached images where appropriate
Bird Deterrent Equipment
-
Assess and test the components of the Bird Deterrent Equipment
-
Are all components in good condition?
-
Please describe the condition, note the location and attached images where appropriate
Cleaning of panels
-
Clean panels where dirt, debris or bird droppings are present
-
Please note the location of any panels where excessive soiling was present