  • Audit Title: CTB location with Well Site(s)

  • Client

  • Conducted on

  • Prepared by

  • Field Location:

Storage Tanks / Heater Treater Area

Storage Tank Battery Area

  • Is the location entrance warning signage in place that displays Company Name, Lease Name and acreage along with PPE Required; No Smoking; Authorized Personnel Only; and if needed -Caution Poison Gas Present and Emergency Phone Number?

  • Operator lease sign at the tank battery which includes the Company Name, Lease Name, RR #, and acreage?

  • If fire extinguishers are present are they in compliance?

  • Are H2S signs required at this facility?

  • If H2S is present, is there a Danger "Respiratory Equipment Required Beyond this Point" sign at stairways?

  • Are the NFPA/GHS labels on the storage tanks and VRT(s) and in good condition?

  • Are the tanks labeled with "Danger - Confined Space- Permit Required Entry" signs, and in good condition?

  • Are all of the thief hatches closed on the tanks?

  • How are the Condition of the storage tanks?

  • Are all chemical storage containers labeled with GHS labels, have an SDS attached and in proper secondary containment?

  • Are the VRT(s) properly anchored with guard wires that are marked?

  • Are the electrical panel boxes marked with a "Danger- High Voltage" label?

  • Is the Vapor Recovery Unit free from leaks, oil drum labeled, all lines valves plugged, and current inspection on PRV?

  • Do the lines or valves have plugs where needed?

  • No leaks coming from lines; valves and storage containers?

  • Is the leak small enough that it does not require immediate attention?

  • No signs of contaminated soil in or around berm?

  • Is the berm and containment area around the tanks in good condition?

  • Is there good housekeeping inside and around the berm?

  • Are the stairs and walkways in a safe condition?

  • Condition of Walkway and Stairs

  • Are the Load lines barricaded if they extend beyond the berm?

  • Are the load line catch pans in good condition with no residue or trash left in them?

  • Is there an identifiable ground connection by or on the load line for the transport haulers to use?

  • Is proper guarding in place on electrical motors and pumps?

  • Are the storage tanks and load lines grounded?

  • Are the meters, vapor recovery units (VRU), transfer motors, and LACT unit(s) individually grounded?

  • Is the windsock present and in good condition?

  • Is the tank battery location safe from driving hazards?

  • Comments

  • Pictures

Heater Treater Area

  • Are the separator and heater treaters labeled with NFPA/GHS; Caution Hot Surface; Danger "Confined Space Entry Permit Required" (if required) signage?

  • Is the secondary containment berm in good condition?

  • Do the chemical storage containers around this area have the GHS labeling, an SDS attached and stored in secondary containment?

  • Are all of the Pressure Relief Valves (PRV) current on inspection dates?

  • Do all lines and valves have plugs where needed?

  • No lines or valves presently leaking in this area?

  • No signs of contaminated soil in are around berm?

  • Do vertical ladders that are over 20' have fall protection such as ladder cages?

  • Are all electrical panel boxes marked with "Danger High Voltage" label?

  • Is housekeeping good for this area? (inside and around the berm)

  • Comments

  • Pictures

Flarestack Area

  • Is there a Flare Stack at this location?

  • Is there a separator / scrubber or knock-out pot present and does it have the GHS/NFPA labeling?

  • Are all of the PRV's current on inspection date?

  • Is the flare pad or the secondary containment in good condition?

  • Is the flarestack the proper distance from storage tanks (75') and combustable material?

  • Are the flare guide wires anchored properly, marked or flagged?

  • Are all plugs installed on lines and valves?

  • Is there a flare arrestor or check valve in the line?

  • Is the flare ignition set to auto and is it working?

  • What is the overall condition of the flarestack area?

  • Comments

Combuster Area

  • Is there a Combuster at this location?

  • If guide wires are being used are they anchored properly, marked, flagged or painted?

  • Do all electrical panels have "DANGER - High Voltage" labels on them?

  • Is the combuster at the proper distance from the storage tanks and combustable material?

  • Are all plugs installed on lines and valves?

  • No chemical leaks, spills or contaminated soil in this area?

  • Is the combuster ignition set to on and is working?

  • Is there a flame arrestor or check valve in the line?

  • What is the overall condition of the combuster area?

  • Comments

Salt Water Disposal Well

  • Is there a salt water disposal well on site?

  • Do the tanks have proper signage? (NFPA/GHS, Confined Space- Permit Required)

  • Do all electrical panels have "DANGER - High Voltage" labels on them?

  • Is secondary containment in good condition?

  • Are the stairs and platforms in good condition?

  • Do chemical totes have the GHS label, an SDS attached and in secondary containment when needed?

  • Valves and lines are not leaking product?

  • Are the tanks and all load lines grounded and in good condition?

  • If fire extinguishers are present are they in compliance?

  • Is there good housekeeping around this area?

  • Comments

Pipeline Risers, Meter Runs, and Right of Way

  • Is there a pipeline riser or meter run at this location?

  • Are the Pressure Relief Valves (PRVs) within inspection date?

  • Are all plugs installed on lines and valves and lines?

  • Do all electrical panels have "DANGER - High Voltage" labels on them?

  • Good housekeeping in this area?

  • Do chemical containers have GHS labels, an SDS attached and in secondary containment?

  • Is there a separator / scrubber present and does it have the GHS/NFPA labels?

  • Area free of spills or leaks?

  • Do the pipelines have a tracer wire?

  • Are traffic barricades present where needed?

  • Are buried gas lines identified with pipeline markers?

  • Comments

Well Head / Compressor Area

Well Head -1 Area

  • Is there a well at this location?

  • Well Head
  • What is the well head name?

  • Is the Lease Sign with the operator name and well number present at the well?

  • Power boxe(s) labeled with Danger "High Voltage"

  • Are the power boxes and well head grounded?

  • Have all trip hazards been eliminated around well?

  • Do all chemical containers have GHS labels, an SDS attached and proper secondary containment?

  • Are all valves and lines plugged?

  • No present leaks or spills around well head area?

  • No soil contamination in this area?

  • Is there a pump jack on this location?

  • Are ladders that extend 20' have fall protection such as ladder cages?

  • Are Caution Automatic Start Sign posted?

  • Condition of diesel or gas motor for the pump?

  • Are the pump fly wheels barricaded and with guards that protect from reaching in?

  • Is the cellar and mouse hole covered or back filled?

  • Are the pump belts properly guarded?

  • Is Hearing protection is required in this area?

  • Are signs posted in this area?

  • Is the well pad safe from driving hazards?

  • Good housekeeping around well?

  • Comments

Compressor Area

  • Is there a compressor on site?

  • Compressor
  • Is there a compressor on site?

  • What signage is missing around compressor?

  • Do the electrical boxes have DANGER High Voltage signs?

  • Are stairs, walkways and work platforms in safe condition?

  • Are the chemical containers labeled and in proper containment?

  • Is the bulk oil tank properly labeled and in proper containment?

  • Are plugs installed on lines or valves?

  • Are PRV's within inspection dates?

  • No leaks from lines, containers and equipment in this area?

  • No visable sign of contaminated soil?

  • Are compressor skids clean of debris and not leaking fluids?

  • Is there proper machine guarding?

  • Separator present with GHS / NFPA labels?

  • Blow down tank present and does it have the GHS / NFPA?

  • Does it have proper secondary containment?

  • Does it have GHS / NFPA and Confined Space labels.

  • Is the bulk coolant tank properly labeled and in proper containment?

  • Are used oil and oil filters stored properly with a labeled container?

  • Good housekeeping in this area?

  • Are fire extinguishers present?

  • Does the extinguisher have a current Yearly and Monthly inspection tag in place?

  • Is the extinguisher operational?

  • What is the location number or compressor number?

  • Are compressor units individually grounded?

  • Are hearing levels below 85 decibels and if not what are the decibel levels?

  • Are "Hearing Protection Required" signs posted?

  • Comments

Frac Site

  • Are Frac operations on this site?

  • Name of the Frac Company

  • Name of the Frac Supervisor

  • Is Personal Protective Equipment being used?

  • Is FR clothing, eye protection, steel toe boots and hard hats being used by all?

  • Are Respirators being used around frac sand movement?

  • Is chemical protection (face, hands, body) being used around chemicals?

  • Is hearing protection being used around pumping equipment?

  • Is Fall protection being used correctly when needed?

  • Proper signage and sign in sheet (JSA) at entrance to pad. Ref. API RP 67 2.4.2, API RP 54 5.1-5.4' I.S., API RP 49, RP54 8.41d, 1910.145(c)(2)(I)

  • Water manifold to tanks free of leaks, all valves to operate present , and in containment if re-use water is used. Ref. CHK BMP, I.S.

  • All tanks are in proper containment?

  • Stairs, handrails, and walkways pinned, connected and not damaged, with no open holes. Ref. RP54 9.3.8, 1910.24(h)

  • Are SDS's available for all chemicals? Ref. 29 CFR 1910.1200

  • Blender, hydration unit, and sand unit caution taped off. Ref. API 5416.1.10

  • Blender, hydration unit, chemical-add units and sand unit properly bonded and grounded?

  • Hammer unions clean and dressed free of mushrooms. Ref. RP54 12.5.1

  • Is emergency shower and eyewash trailer on location? Ref Z358

  • Is the trailer clearly identified as an "EMERGENCY SHOWER/WASH"

  • Is the power supply operational?

  • Is the proper amount of water available?

  • Does the eye wash and shower have water pressure when activated?

  • Are light towers properly grounded? Ref RP 2003

  • All electrical extension cords shall be properly insulated and plugs shall be in good condition. Ref. RP54 9.14.5

  • Walkways and work areas have clear paths?

  • Spotters are used when backing equipment?

  • Pictures of areas.

  • Comments

Drilling Site

  • Are there drilling operations on this location?

  • Have you filled out the separate drilling rig audit?

Misc. and Other Items

  • Notes

  • Pictures

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.