Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
Vehicle ID/Bus #
Luminator Mobile Video W/INFOTransit FAI Inspection
Mobile Video
-
DVR Model Numbero
-
DVR has power/power light is red at startup
-
Active Recording/Record light
-
Verify Latest Firmware
-
Verify Correct Config/Load if Necessary
-
Correct Date and Time Is Set
-
Hard Drive Is Running and Locked
-
Verify 30 Day Recording Setting Before Overwrite
-
Verify Proper IP Address
-
DVR mounting Plate Is Secure To Surface
-
Rear Connections Are Tight and Wires Have Slack
-
Accelerometer Is Functioning.
-
Verify All Discretes. (Left Turn, etc) Trigger The Discrete and Verify That The Appropriate Alarms 5-16 in "Status Tab" and Is Listed In "Event Panel"
ODC
-
Connect to each ODC and verify Firmware version
-
Connect to Each ODC and Verify Configuration Matches Customer Requested Views on Monitors
NiiU
-
Connect to Niiu and Verify Software Version
-
Verify The Config Is Current
Power Terminations
-
Visible Cabling Is Secured and Not Chafing
-
Ring Terminals To Power and/or Secure
Cabling
-
All Visible Cabling Is Secured and Not Chafing
-
Sufficient Cable Stress Relief When Tray Slides Out
-
Admin Cable Is Neatly Coiled and Easily Accessed
Wireless Radio/Router
-
SSID is programmed?
-
Add ip’s for cellular and WIFI
-
Verify Remote Connection To The DVR Using Mset With Live
-
Test Uploading Driver Event Clip
Event Marker
-
Event Button flashes green – normal
-
Button turns red for 5s when pressed
-
Button triggers in RSM
-
Button is securely mounted
-
Visible cabling is secured and not chafing
Power Supply
-
Check Proper Voltage Coming In and Out
-
DVR Continues To Run When Power Is Cut Off
-
UPS Is Securely Mounted
-
Connectors and Pins Are Secure
Monitors
-
Passenger View Monitor Is Securely Mounted
-
Passenger Monitor Displays Correct Camera View
-
Drivers View Monitor Is Securely Mounted
-
Drivers Monitor Displays Correct Camera View
Cameras
-
Verify Each Camera Is Securely Mounted
-
Verify Each Interior Camera Has Foam Seal Installed
-
Verify Each Exterior Camera Has Foam Seal Installed
-
Verify Each Interior Camera Has Microphone
-
Verify Audio For Each Camera Microphone
-
Verify Audio For Both External Microphone
-
Verify Each Interior Camera IR Is Working Properly
-
Verify Each Interior Dome Camera Has Rubber Boot On The Lens
-
Verify The Exterior Rear Camera Does Not Have A Microphone
-
Verify Forward Facing Camera View. Adjust Boot cover if needed
Camera Views
-
Add media
Sign Offs
-
Luminator Representative
-
Title
-
Date
-
OEM or Transit Authority Representative
-
Title
-
Date
INFOtransit
-
Monitor 1 TFT #
-
Monitor 2 TFT #
-
Monitor 3 TFT #
-
Monitor 4 TFT #
-
VAS Model Number
Physical Installation
-
Monitor 1 mounted securely
-
Monitor 1 Cabling Secured Neatly
-
Monitor 2 Mounted Securely
-
Monitor 2 Cabling Secured Neatly
-
Monitor 3 Mounted Securely
-
Monitor 3 Cabling Secured Neatly
-
Monitor 4 Mounted Securely
-
Monitor 4 Cabling Secured Neatly
-
Multimedia Computer and Auxilary Equipment Cabling Secured Neatly
-
Mutlimedia Computer and Auxilary Equipment Mounted Securely
-
GPS Antenna Mounted Securely
-
GPS Antenna Cabling Secured Neatly Away From Other Antennas
-
GPS/WLAN Antenna Cable secured at Multimedia Computer and Bend Radius is Observed
-
Is The Mounting Surface Sufficient For Anticipated Loads
Functional Test
-
Monitors Do Not Operate In Master Run
-
Monitors Operate In Master Run "DAY" Position
-
Monitors Operate In Master Run "Night" Position
-
Monitors Do Not Operate In Master Run "Park" Position
-
Using MCU and Monitor Status Screens, verify GPS Satellite reception NOTE: Must Be Outside and Operational For 5 minutes
-
Using MCU and Monitor Status Screens, Verify Stop Request and Door Inputs
-
With Both Doors Closed, Verify Stop Request Function Displays on Monitors
- Pass
- Fail
- N/A
-
Open front door, verify Stop Request message is cancelled on Monitors
-
With Both Doors Closed, Verify Aid Stop Request Function Displays on Monitors
-
With Both Doors Closed, Verify Bike Stop Request Function Displays On Monitors
-
Open Rear Door, Verify Aid Stop and Bike Request Message Is Cancelled On Monitors
-
Verify Security Camera Feeds Are Displayed In Media Display Pool
-
Monitors Blank After Shut Down (Delay)
-
Programmed with Test Data Set
-
Confirm Destination Code Selection via AVL System
Electrical Characteristics
-
Are Vehicle Circuit Breakers Properly Rated?
-
Are All Wires Of Correct Gauge For Peak Anticipated Loads?
-
Are Exposed Wires, Subject To Wear and Possible Damage, Protected With An Abrasion Shield?
-
Are Antennas Routed Away From Communication Cables
Software
-
Verify Software Version
-
Verify Presentation Running On All Monitors
-
Does System Shut Down After Pre-Determined Amount Of Time
-
Is SW Port on VAS Controller (for upgrades, diagnostics) Acessible Without Major Disassembly?
-
Does The Vehicle ID Show On The Status Screen?
-
Is the MCU IP Address Correct?
-
Is the VAS Controller IP Address Correct?
-
Verify IP Address for Monitor #1 (Primary)
-
Verify IP Address for Monitor #2
-
Verify IP Address for Monitor #3
-
Verify IP Address for Monitor #4
-
Do Camera Views Display on all the INFOtransit Monitors
-
Does The Video Play On All The INFOtransit Monitors
-
Does The Audio Of The Video Play OnAll INFOtransit Monitors?
-
Does The Correct GPS Lat/Long Show On The Status Screen?
-
Is The Time Correct On The Status Screen?
Sign Offs
-
Luminator Representative
-
Title
-
Date
-
OEM/TA Representative
-
Title:
-
Date: