REFRIGERATION CABINETS
-
Refrigeration Cabinets installed
Cabinet type
-
Add media
-
Are door hinges operating correctly?
-
Are door handles correctly mounted ?
-
Are the door seals intact?
-
Are the lights in the cabinet working?
-
Are the glass panels in good condition?
-
Do the fans appear to be working correctly?
-
Are the corner protectors in place?
-
Are the kick-plates in place and fitted correctly?
-
Is the cabinet clean?
-
Is the cabinet in good condition?
SELF CONTAINED REFRIGERATION CABINETS
SELF CONTAINED CABINETS
-
Self contained refrigeration units installed?
Cabinet type
-
Add media
-
Are the door hinges operating correctly?
-
Are the door handles correctly mounted and in good condition?
-
Are the door seals intact?
-
Are the door anti-sweat heaters working?
-
Do the fans appear to be working correctly?
-
Are the lights in the cabinet working and correctly mounted?
-
Are the condenser coils clean?
-
Are the glass panels in good condition?
-
Are the kick-plates in place and fitted correctly?
-
Is the cabinet clean?
-
Is the evaporator coil free from excessive ice build-up?
-
Is the compressor free from visible oil leaks?
-
Is the refrigerant piping free of visible leaks and vibration?
-
Is the refrigerant piping insulation in good condition?
-
Do all visible electrical junction boxes have cover plates?
-
Are the condenser coils clean and free from corrosion?
-
Are the condenser fans operational?
COMPRESSORS
-
Compressors installed?
CENTRAL AIR CONDITIONING SYSTEM
CENTRAL AIR CONDITIONING PLANT ROOM
-
Central Air conditioning Plant Installed?
Equipment type
-
Add media
-
Are the lights in the plant room working?
-
Is the plant room clean?
-
Is fire equipment mounted correctly, correct signage displayed and fall within the valid inspection date?
-
Is the equipment free from visible oil leaks?
-
Are the compressor oil levels correct?
-
Is the safety control switch capillary tubing free of vibration and chafing?
-
Is the refrigerant piping free of visible leaks and vibration?
-
Is the refrigerant piping insulation in good condition?
-
Is the system clear of any alarms?
-
Do electrical panels have covers and are they labelled?
-
Are the condensate drains clean and unobstructed?
-
Do all electrical junction boxes have cover plates?
-
Are the filters clean and in good condition?
-
Do the electrical distribution boards have doors and latch properly?
-
Are the circuit breakers labelled clearly and in an acceptable manner?
CONDENSERS
-
Air cooled condenser installed?
Air cooled condenser
-
Add media
-
Are the condenser fans operational?
-
Are the coils clean and free from corrosion?
-
Is the refrigerant piping free of visible leaks and vibration?
-
Is the safety control switch capillary tubing free of vibration and chafing?
-
Is there sufficient ventilation in the plant room?
WATER COOLED CONDENSERS
-
Water cooled condensers installed?
Water cooled condensers
-
Add media
-
Water treatment system operational with adequate chemicals?
-
Are the cooling tower fans operational?
-
Does the condenser pump operate correctly? ( Noise, water leaks, vibration etc)
-
Does the spray/ circulating pump operate correctly? ( Noise, water leaks, vibration etc )
-
Is the capacity control damper operational?
COMPRESSORS
-
Compressors installed?
Compressor type
SPLIT TYPE AIR CONDITIONING EQUIPMENT
SPLIT TYPE AIR CONDITIONING UNITS
-
Split air conditioning units installed?
Equipment type
-
Add media
-
Condenser coil clean and in good condition?
-
No visible refrigerant leaks?
-
Condenser fan operational?
-
Refrigerant piping insulation in good condition?
-
Heating and cooling functions operational?
-
Remote control operation functional?
-
Filter clean and in good condition?
COMPRESSORS
-
Compressors installed?
-
Add media
-