I. GENERAL AND ADMINISTRATIVE

A. Electrical

  • 1. Are the lighting circuits properly wired and do they have adequate<br>fuses and circuit breakers?

  • 2. Is all permanent wiring in approved conduit and free of "juryrigging" such as extension cords in place of proper electrical cabling?

  • 3. Are the high amperage circuits which provide power to battery<br>chargers, heavy duty fans and ventilators, etc. properly wired and do<br>they have adequate fuses and circuit breakers?

  • 4. Does the supervisor enforce a "Lockout/Tagout" policy for electrical<br>machinery repair?

  • 5. Is all electrical equipment effectively grounded IAW NFPA 70<br>(National Electrical Code)?

B. Chemical (Asphyxiants)

  • 1. Are the administrative and general areas free of high levels of carbon<br>monoxide? Carbon monoxide Time Weighted Average (TWA) is<br>listed in Table 1.1.1.<br><br>

C. Chemical (General)

  • 1. Does the motor pool have a current file of Material Safety Data Sheets<br>(MSDS) for all hazardous materials used in the motor pool? Are they<br>available to the employees, and do they understand them?

D. Ignition Sources

  • 1. Is the wiring and are electrical devices checked to ensure they do not<br>arc excessively nor overheat and produce ignition sources?

  • 2. Does the supervisor enforce "No Smoking" requirements?

  • 3. Are there other ignition sources such as portable heaters, dryers,<br>coffee pots, hot plates, etc. and are they properly controlled?

  • 4. In the repair area are all electrical ignition sources at least 46 Cm<br>(18") above the floor?

  • 5. Are all electrical switches in the maintenance area "explosion proof"?

E. Mass

  • 1. Are file cabinets, book cases, and other document storage areas<br>properly secured?

F. Rotating Equipment

  • 1. Are fans or any other moving/rotating equipment less than 2.13<br>meters (7 feet) above the floor properly guarded?

  • 2. Does the supervisor instruct personnel that loose clothing, ties, long<br>hair, and jewelry may catch in moving machinery? Are such items<br>prohibited?

  • 3. Are running machines attended at all times?

  • 4. Is there adequate space around each machine or lift to allow the<br>operator to conduct necessary maintenance work without danger?

  • 5. Are all drive belts and other exposed rotating equipment properly<br>guarded?

  • 6. Is there a "Lockout/Tagout" program in place to ensure safe<br>maintenance of motor pool equipment and powered machinery?

G. Noise

  • 1. Does steady state noise in the administrative area exceed the limits in<br>Table 1.1.1 (85 dBa).

H. Earthquake

  • 1. If the area is subject to earthquakes, is there a disaster plan for the<br>warehouse and has it been exercised in the past year?

I. High Wind, Tornado

  • 1. If the area is subject to high winds, hurricanes, or tornadoes, is there<br>a disaster plan for the warehouse and has it been exercised in the<br>past year?

J. Flooding

  • 1. If the area is subject to flooding, is there a disaster plan for the<br>warehouse and has it been exercised in the past year?

K. Static Electricity

  • 1. If the location is subject to lightning, is the building properly<br>protected against lightning strikes or secondary ground surges?

  • 2. If the location is subject to a high buildup of static electricity, is there<br>an SOP for control of static electricity, particularly where flammable<br>materials are used?

L. Personnel

  • 1. Does the supervisor ensure that all employees know and adhere to<br>safety requirements in the motor pool operation?

  • 2. Are noise sources controlled to the point that noise does not interfere<br>with warning signals in the motor pool?

  • 3. Does the supervisor ensure that employees only use machines for<br>which they are qualified?

  • 4. Does the supervisor ensure that PPE is used properly and that<br>employees are not to take "short cuts"?

  • 5. Are the proper warning/caution signs posted where the employees<br>can see them?

  • 6. Is the lighting adequate in all the work areas?

  • 7. Are bilingual "NO SMOKING" signs posted and is the policy<br>enforced?

  • 8. Does the supervisor ensure that high housekeeping standards are<br>maintained?

M. Fire Protection

  • 1. Is good housekeeping practiced at all times? Is the trash, and<br>especially flammable or combustible trash, taken out every night?

  • 2. Are oily or greasy rags placed into a metallic covered container?

  • 3. Does the supervisor have a current emergency and evacuation plan?

  • 4. Does the motor pool have working fire detection system? Is it<br>regularly maintained?

  • 5. Does the motor pool have the required number and types of fire<br>extinguishers and are they properly located? Have the employees<br>been trained in the proper use of the fire extinguishers?

  • 6. Have there been any changes in operations, or procedures which<br>would require re-positioning of the present fire extinguishers?

II. GENERAL MAINTENANCE AREA

A. Chemicals

  • 1. Are flammables and combustibles limited to small amounts needed<br>in the immediate area and are they stored in approved UL/FM<br>flammable liquids storage cabinets?

  • 2. Are asphyxiants, primarily carbon monoxide levels maintained<br>below the 8 hour TWA, listed in Table 1.1.1, particularly during<br>periods of inclement weather?

  • 3. Does the shop manager control asbestos levels, particularly in repair<br>to brakes and clutches, in accordance with Appendix 1 in Chapter 1.

  • 4. Are the mechanics aware of the nature of the asbestos threat?

  • 5. Does the shop manager prohibit the use of low pressure air to clean<br>brake assemblies?

  • 6. Are hazardous wastes disposed of in accordance with U.S. or host<br>country regulations, whichever is more stringent?

B. Ignition Sources

  • 1. Are there any wall outlets or other connections within 46 Cm (18") of<br>the floor?

  • 2. Are there any motors or other potential arc producing electrical<br>equipment used or stored within 46 Cm (18") of the floor? These<br>could serve as an ignition source in the event of a gasoline spill in the<br>motor pool maintenance area.

  • 3. Are there any hot plates, coffee pots, or other small personal<br>appliances in the work area which could serve as an ignition source?

  • 4. If there is a maintenance pit with lighting, are the fixtures "explosion<br>proof" IAW the NFPA 70, Article 511

C . Mass (Jacking/Lifting)

  • 1. Are vehicles properly positioned on lifts and are they checked prior<br>to lift operation?

  • 2. Are the proper capacity jacks used and are they the proper jack in<br>capacity and design to lift the vehicle?

  • 3. When using jacks, are jack stands used to ensure the stability of the<br>vehicles which have been lifted on jacks, prior to working on the<br>vehicle?

E. Moving Vehicles

  • 1. If there is a maintenance pit, does it have a cover to keep people from<br>falling into it?

E. Moving Vehicles

  • 1. Does the motor pool manager ensure that personnel working are<br>warned of moving vehicles either by a back-up horn or other suitable<br>devices when vehicles are being moved about in the shop?

  • 2. When maneuvering in close quarters, especially backing, are backers<br>or guides used?

  • 3. When being serviced are the vehicles locked, placed in gear, or<br>chocked to prevent movement?

  • 4. Are vehicle ignition keys controlled to ensure that the vehicle is not<br>started inadvertently while someone is working on it?

F. High Pressures

  • 1. Are the compressor, air storage tank, manifolds, and airlines<br>inspected regularly to ensure the integrity of the system?

  • 2. Has the air system been "stepped down" to provide low pressure air<br>for air driven tools, etc?

  • 3. Are the air driven tools (impact wrenches, for example) inspected<br>regularly?

  • 4. Are the hydraulic lifts inspected and tested according to the<br>manufacturer's or local government's requirements?

  • 5. Are the hydraulic jacks inspected in accordance with the<br>manufacturer's or local government's requirements?

  • 6. Are bottles of compressed gases, such as freon, properly stowed and<br>secured? Are the valves protected with a cap.

III. WELDING

A. Electrical

  • 1. Is all permanent wiring in approved conduit and free of "juryrigging" such as extension cords in place of proper electrical cabling?

  • 2. Are the high amperage circuits which provide power to the electric<br>arc welder and other high power machines properly wired and do<br>they have adequate fuses and circuit breakers?

  • 3. Are equipment "On-Off" switches color coded (STOP – Red, RUN –<br>Black, Green, or other approved color).

  • 4. Can the welder reach the emergency shut off easily?

  • 5. Does the supervisor enforce a "Lockout/Tagout" policy for repair?

  • 6. Is all electrical equipment effectively grounded IAW NFPA 70<br>(National Electrical Code)?

  • 7. Is the grounded side of the electric welding circuit always attached to<br>the part being welded?

B. Chemical

  • 1. Are the welders familiar with the fluxes, types of welding rods, and<br>other hazardous materials used in welding? Do they have MSDS<br>sheets for these materials?

  • 2. When welding brazing, or similar activity generates toxic fumes and<br>gases, is the ventilation adequate to ensure that the fumes do not<br>exceed the material's TWA, listed in Table 1.1.1.

  • 3. Is there sufficient make-up air to ensure that TWA's are not<br>exceeded?

C . Radiation

  • 1. Does the supervisor ensure that proper PPE, including the proper<br>shade of glass is used in any welding/cutting/ brazing or similar<br>operation.

  • 2. Are screens provided to protect those outside the welding areas from<br>UV/IR radiation from either gas or electric welding?

  • 3. Is the welding area free of ordinary combustibles?

D. Projectiles

  • 1. Are protective caps on compressed gas cylinders in place when in<br>storage, in transit, or other time when a regulator is not attached to<br>the cylinder?

  • 2. Are the cylinders stored upright, fastened to prevent upset, kept<br>separate by type, free from external damage and free from<br>temperature extremes, particularly high temperatures?

  • 3. Are cylinders checked for leaks, corrosion, current test date, and<br>evidence of physical damage before accepting the cylinders?

  • 4. Are cylinder valves closed by hand only?

  • 5. Is there an SOP (Standing Operating Procedure) for handling<br>problem gas cylinders?

  • 6. Is there a schedule for maintenance of air receivers of air compressor<br>tanks?

  • 7. Do the cylinders meet either DOT and local specifications (if local<br>requirements are more stringent use these)?

IV. BATTERY CHARGING

A. Electrical

  • 1. Are the cables, converters, chargers, and allied electrical equipment<br>properly wired and fused?

  • 2. Is all permanent wiring in approved conduit and free of "juryrigging" such as extension cords in place of proper electrical cabling?

  • 3. Are the high amperage circuits which provide power to battery<br>charger, properly wired and do they have adequate fuses and circuit<br>breakers?

  • 4. Is battery charging only done in the designated area?

  • 5. Are equipment "On-Off" switches color coded (STOP – Red, RUN –<br>Black, Green, or other approved color)?

  • 6. Can a machine operator reach the emergency shut off easily?

  • 7. Does the supervisor enforce a "Lockout/Tagout" policy for electrical<br>machinery repair?

  • 8. Is all electrical equipment effectively grounded IAW NFPA 70<br>(National Electrical Code)?

B. Chemical

  • 1. Is the battery charging area properly ventilated to ensure that there is<br>no dangerous buildup of hydrogen gas from off-gassing batteries?

  • 2. Is there an eye wash station in or near to the battery charging area?

  • 3. Do warehouse personnel know the procedures for the cleanup of any<br>hazardous material spill?

V. TIRE REPAIR

A. Projectiles

  • 1. Does the tire repair area have a tire restraining cage for handling<br>multi-piece and single piece rim-tire combina-tions?

  • 2. Is the cage firmly anchored to the floor?

  • 3. Is the cage free of cracks and signs of corrosion in the structure and<br>the anchor bolts?

  • 4. Is the control on the airline far enough away that the operator can<br>inflate the tire in the cage and still not be in the trajectory should the<br>wheel assembly come apart?

  • 5. Does the airline have a gauge at the control?

  • 6. Does the supervisor ensure that tire changers are properly trained?

  • 7. Is "Demounting and Mounting Procedures for Truck/Bus Tires"<br>posted in the tire changing area?

  • I certify that all the information listed in the above report are correct and true.

  • Ariel Mariano, A/POSHO

  • Gus Kosmas, POSHO

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.