Title Page
-
Audit Title
-
Client
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Main service wire conductor as correct overhead clearance
-
Utility's responsibility
-
Customers responsibility
-
Overhead clearance in main panel is a potential hazard.
-
Immediate attention needed!
-
Copper wire is only wiring conductor in home
-
Immediate attention needed!
-
Whole house surge protection is present on electrical system
-
A lightning storm, a bird or animal hitting a power line or transformer, or a freak accident. Any of those incidents, and many others, can cause a power surge, which is a spike in the amount of electricity that's moving through the power lines into your home. A surge can bring with it anywhere from five to 10 times the normal amount of electricity
-
Immediate attention needed!
-
All wiring at distribution system is correct
-
Immediate attention needed!
-
Point of access connections are encased and protected
-
Immediate attention needed!
-
Breakers are sized correctly
-
A fuse(s) or circuit breaker(s) is needed in any electrical system (AC or DC). These protection devices react to the amount of heat being produced by electricity passing through wires and/or components. They are used to protect wires and components from the extreme heat produced should there be an electrical overload or short circuit.By having the wrong sized disconnects, fuses and breakers it may cause your electrical system to not be protected adequately which could result in a home fire. In
-
Immediate attention needed!
-
Grounding and Bonding is up to National Electric Code
-
Immediate attention needed!
-
AFCI protection
-
How many circuit need AFCI protection
- 1-3
- 4-6
- 7-9
- 10-13
- 14-20
- 20-more
-
Over 70% of house fires are caused by loose connections. Loose connections cause small arcs of electricity. A AFCI device detects this really small jumps of electricity and shuts off before a major issue arises.
-
Immediate attention needed!
-
GFCI protection
-
Where is GFCI protection needed
- bathrooms
- kitchen
- outdoors
- garage
- basement
-
A ground fault happens whenever electricity escapes the confines of the wiring in a kitchen appliance or light fixture and takes a shortcut to the ground. When that short cut is through a human, the results can be deadly. About 200 people in the U.S. alone die of ground faults each year, accounting for two-thirds of all electrocutions occurring in homes. GFCI protection reduces this risk.
-
Immediate attention needed!
-
Adequate security lights outside
-
Adequate outdoor lighting is a benefit not only because it can make your property more aesthetically pleasing, but also because it drastically increases safety and security. At Mr. Electric we offer a wide range of outdoor lighting options that would fit your needs perfectly
-
Immediate attention needed!
-
All outdoor wiring to spall, pool and sprinkler systems are to code
-
Immediate attention needed!
-
All accessible outlets have correct polarity
-
Immediate attention needed!
-
All accessible outlets are grounded
-
Immediate attention needed!
-
All outlets are tamper-resistant
-
Immediate attention needed!
-
Water heater, air conditioner, and furnace can be safely disconnected during an emergency
-
All major appliances and electrical systems must have disconnecting mean in sight of equipment in cases of emergencies.
-
Immediate attention needed!
-
All smoke & Co2 alarms are 10years or newer
-
Immediate attention needed!
-
All smoke & Co2 alarms Sound & are interconnected?
-
Every year approximately 3000 people die each year in the U.S. in result to home fires. It is very common for people to remove the batteries when the smoke alarm sound goes off. The dangerous thing is that since the beeping is no longer annoying us, we forget to replace the batteries which can result in great loss and damage. The other deadly danger is carbon monoxide. It is the leading cause of poisonous deaths. Carbon monoxide is a colorless, odorless, tasteless, and deadly gas.
-
Immediate attention needed!
-
Proper placement of smoke and carbon monoxide detectors
-
The Proper location for alarms are in every bedroom, outside of every living area or in common areas.
-
Immediate attention needed!
-
Attic wiring is visibly correct
-
What issues are present?
- open splices
- open junction boxes
- wires damaged
- nob and tube wiring
- other
-
Immediate attention needed!
-
Is there anything else that needs to be noted?
-
Customer signature