Minimum Standards to be achieved. Please see below notes on any failures to meet minimum safety standards and works required.

1- A fully functioning fire alarm system covering all areas. L1 break glass call points and detection devices.

  • Minimum Standard met.

2- Suitable and sufficient emergency lighting throughout all areas of the building.

  • Minimum Standard met.

3- Sprinkler heads at low level, at risk of damage to be suitably protected.

  • Minimum Standard met.

4- All new and existing fire doors protecting staircases and dead end conditions to be fully compliant. ( Undamaged with strips, seals and self closer.)

  • Minimum Standard met.

5 - Fallow areas to have fire detection, emergency lighting and means of escape.

  • Minimum Standard met.

6- No doors on fire escape routes to require keys to enable doors to open.

  • Minimum Standard met.

7- Where possible, all fire doors to open in the direction of travel.

  • Minimum Standard met.

8- If a final exit does not lead to a place of total safety, it should not be an exit.

  • Minimum Standard met.

9- Any locked doors to have ease of exit e.g. Thumb twist

  • Minimum Standard met.

10- Suitable and sufficient fire escape signage throughout the building. Including sales floor where hanging signs may be required.

  • Minimum Standard met.

11. Excessive travel distances need to be considered at scope and addressed within design where practical.

  • Minimum Standard met.

12- All breaches in new and existing fire walls addressed using suitable material.

  • Minimum Standard met.

13- Electrical board cupboards to be locked and signed.

  • Minimum Standard met.

14- Unprotected electrical cupboards to have defined clearance area.

  • Minimum Standard met.

15- Any fragile roof where there is a risk it will be used for storage to be meshed and signed.

  • Minimum Standard met.

16- Suitable delivery processing and grey tote storage areas identified and designated.

  • Minimum Standard met.

17- Footwear aisle widths to be a minimum of 800mm.

  • Minimum Standard met.

18- Outdoor stores - Suitable LPG storage area to be identified and provided.

  • Minimum Standard met.

19- Asbestos removed were practical, or encapsulated and labelled were not.

  • Minimum Standard met.

20- Welfare facilities must include heating, ventilation, hot water, drinking water and seating.

  • Minimum Standard met.

21- New an existing platform lifts - Floor beneath platform to be coloured bright red and large signage applied on floor to indicate no unauthorised access. Emergency stop device beneath platform to be identified with sign.

  • Minimum Standard met.

22- Any trip hazards to be removed or highlighted across shop floor and back of house.

  • Minimum Standard met.

23- Staircases to have handrail and nosing of a contrasting colour to all steps.

  • Minimum Standard met.

24- Equality and accessibility considered and physical barriers removed or overcome were practicable. Areas to consider access/egress, welfare, lifts, ramps and refuge points.

  • Minimum Standard met.

25- Building fabric throughout sound, safe and secure.

  • Minimum Standard met.

26- Safety included in scope notes and safety team included in circulation.

  • Minimum Standard met.

27- Any safety concern not covered in the above to be raised with safety team and a satisfactory solution agreed.

  • Minimum Standard met.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.