1.0 - Previous inspection
-
1.1 - Has the last inspection been reviewed?
-
1.2 - Are there any outstanding actions?
-
1.3 If yes to the above, are they identified in the Continuous Improvement Plan for the premises?
-
1.4 - Has there been any significant change to the office or change in office location since last audit?
-
If yes to the above please comment.
2.0 Fire & Emergency
-
2.1 - Evacuation plan posted in prominent location eg notice board?<br>
-
2.2 - Evacuation and emergency procedures discussed and drills conducted regularly? (3 to 4 times a year)
-
2.3 - Are local details on this form correct?
-
If no, print new form with updated details (available on intranet)
-
2.4 - Extinguishers in place, clearly marked for type of fire?
-
2.5 - Extinguishers in place and appropriate for the hazard?
-
2.6 - Extinguishers and hoses recently serviced? (Check 6 monthly punch mark on tabs.)
-
2.7 - Extinguishers mounted, unobstructed and location signs clearly visible?
-
2.8 - Exit signs and directions to exits?
-
2.9 - Exit signs illuminated?
-
2.10 - Exits clear of obstructions?
-
2.11 - Exit doors easily opened from inside?
-
2.12 - Fire detection equipment inspected & maintained?eg smoke alarm, sprinklers & thermals?
-
2.13 - Smoke alarms installed?
-
2.14 - Fire alarm system functioning & tested regularly?
3.0 - Lighting & Ventilation
-
3.1 - Workspaces well lit?
-
3.2 - Light fittings clean and in good condition?
-
3.3 - Air-conditioning system maintained?
-
3.4 - Comfortable temperature?
4.0 - Building Safety & Housekeeping
-
4.1 - Floor surfaces even and uncluttered?
-
4.2 Floors maintained clean, dry & tidy?
-
4.2 - Free from slip/trip hazards?
-
4.4 - - Entry and walkways kept clear?
-
4.5 - Offices clean & tidy?
-
4.6 Aisles and walkways unobstructed?
-
4.7 - Sufficient rubbish bins are provided & emptied regularly?
-
4.8 - Are liquid spills removed quickly?
-
4.9 - Are railings in good condition?
-
4.10 - Car parking is satisfactory? eg surface, lighting, ventilation?
-
4.11 - Building access & footpaths satisfactory? eg condition, lighting
5.0 - Work Stations
-
5.1 - Workstations suitable with correct set up?
-
5.2 - Ergonomic chairs provided & adjustable?
-
5.3 - Furniture in sound condition?
-
5.4 - Reflected light not causing glare to employee?
6.0 - Storage & Stacking
-
6.1 - Neat stacking of supplies?
-
6.2 - Filing cabinets & shelving tidy & in good condition?
-
6.3- Storage of all items at shoulder height or below?
-
6.4 - Heavy or frequently used items stored at waist height?
-
6.5 - A safe step stool or ladder available, if required?
-
6.6 - All objects left in safe position (none where they could fall?)
7.0 - Electrical Safety
-
7.1 - Safety switches installed?
-
7.2 - Safety switches (RCDs) tested every 6 months and tests recorded?<br><br>SA/QLD - Every 2 years operating time testing. Push button testing quarterly.<br>NSW/ACT - If present (testing as per QLD). Safety switch not required in non-hostile environment.<br>VIC - Every 2 years operating time testing. Push button testing 6 monthly.
-
7.3 - Power use safe ?- No double adapters in use.
-
7.4 - Portable equipment tested and tagged? See note:<br><br>NSW/ACT/QLD - 5 yearly;<br>SA - Includes extension leads & powerboards - 5 yearly;<br>VIC- 5 yearly
-
7.5 - Power use safe ? - No broken plugs, sockets or switches.
-
7.6 - Power use safe ? - No power leads across walkways.
-
7.7 - Power use safe ? - No frayed or damaged leads.
-
7.8 - Power use safe ? - No strained leads & are tidy to reduce trip hazards.
-
7.9 - Powerboards used & fitted with a safety switch, no piggy backed adaptors?
-
7.10 - Is there a clear space in front of switchboards of at least 1 metre?
-
7.11 - Danger tags available for isolation & maintenance of plant & equipment?
8.0 - Plant & Equipment
-
8.1 - The photocopier is safe ? - does not require loose or liquid toner.
-
8.2 - The photocopier is safe ? - does not emit fumes.
-
8.3 - The photocopier is regularly maintained by a properly trained person?
-
8.4 - Safe operating procedures signed at location of photocopier with loose or liquid toner &/or fumes?
-
8.5 - Safe Operating procedures signed at location of guillotine &/or shredder?
9.0 - Chemical Safety
-
9.1 - Are Material Safety Data Sheets (MSDS) available for all chemical available & accessible to staff, & are current (within 5 years). eg for dishwashing detergent, cleaners.
-
9.2 - Hazardous Substance Register complete and available?
-
9.3 - Containers labelled clearly & correctly?
-
9.4 - If required is PPE available & in good condition? eg gloves (Check MSDS)
10.0.-Amenities
-
10.1 - Clean & tidy toilets, washroom, shower?
-
10.2 - Supplies of soap & disposable hand towels or dryer?
-
10.3 - Water available which is clean, cool & hygienically provided, separate from toilet & washing facilities?
-
10.4 - Is there a health & safety risk from preparing food and eating in the workplace?
-
10.5 - Is there a staff notice board located in common areas?
-
10.6 - Is the Workcover or Safety poster displayed on the staff noticeboard? (NSW & Vic only)
11.0 - First Aid
-
11.1 - First aid kit adequately stocked, contents checklist available & register?
-
11.2 - Are contents regularly checked?
-
11.3 Contents are good ? - No contents past their expiry date.
-
11.4 - Where first aid kit is stored is clearly sign posted & labelled?
-
11.5 - Name & contact for current first aider displayed in prominent locations? ie notice board or with First aid kit
12.0 - Security
-
12.1 - Is accessible secure storage for personal property available? eg lockable drawers
-
12.2 - Are security measures in place & sufficient for the safety of staff?
13.0 Current Office Contacts
-
13.1 - Name of Office Representative for Office, Operational and WHS matters.
-
13.2 - Name of First Aid Officer/s and date/s of certificate expiry
-
13.3 Name of Fire & Emergency Warden/s
14.0 - Other Comments:
-
Enter additional comments here....
Sign Off
-
On site Office Representative
-
Manager
-
Select date