Deficiencies
-
Floors, concrete - cracking or arching
-
Causes
-
Shrinkage, or settlement of subsoil
-
Inadequate drainage
-
Movement in exterior walls, or frost heave.
-
Improper compaction of base. Erosion of base
-
Heaving from hydraulic pressure
-
Floors, wood - rotting or arching
-
Causes
-
Excessive dampness or insect infestation
-
Leak in building exterior
-
Lack of ventilation
-
Wall deterioration
-
Causes
-
Concrete or masonry (see A10 Foundations)
-
Crawl space ventilation and maintenance
-
Causes
-
Inadequate air circulation due to blockage of openings in foundation walls
-
Moisture barrier ineffective
-
Pest control, housekeeping, and prop drainage