Title Page
-
Audit title
-
Site Name
-
Location
-
Address ID
-
Power ID
-
Conducted on
-
Prepared by
Access
-
Access Road clear, no obstructions
-
Access Paths clear, no obstruction
-
Check access to all buildings and structures
-
All EACS/Keys open doors
Site Grounds
-
Check site grounds for loose material debris etc.
-
Any loose material or debris.
-
Check site fence for damage
-
Any loose or unfixed fence components
-
Check condition of large trees on site
-
No branches over building, no dead limbs etc
-
Check trees/vegetation around overhead power supply lines, consumer lines and sub mains
-
No vegetation within the 2.0 m restricted zone of power supply lines
-
Check trees/vegetation around all buildings and structures
-
Is vegetation clear of all buildings and structures
Architectural
-
Check roofs on all buildings and structures
-
No missing/loose roof sheets, tiles, flashings, eaves lining etc
-
Check rain water system
-
No loose guttering/fascia etc. gutters/down pipes clear of vegetation and debris. No evidence of blockages/overflows
-
Check external walls on all buildings and structures
-
No missing/loose wall sheets, flashings etc
-
Check external windows on all buildings and structures
-
No broken windows. Windows secure. Windows sealed. Shutters closed. No evidence if water/dust ingress
-
Check external doors on all buildings and structures
-
Doors secure. Doors sealed. No evidence of water/dust ingress
-
Check internal
-
No evidence of rain ingress ie: stained ceilings/walls
-
Check tie downs and anchors on all buildings and structures
-
Tie downs in good condition. Tie downs connected to anchors. No excessive corrosion. Structures fixed to mass footings
Fire Systems
-
Check Fire Indicator Panel (FIP) on all buildings and structures
-
1. FIP tested within the last month. <br>
-
2. Alarm signal to Telstra P&F and FESA if applicable
-
3. No outstanding defects
-
4. No fire system impairments
-
Check VESDA system on all buildings and structures
-
1. VESDA tested within the last 6 months. <br>
-
2. Alarm signal to Telstra P&F and FESA if applicable
-
3. No outstanding defect
-
4. Alarm signal to Telstra P&F
Air Conditioning Systems
-
Check Air Conditioning system
-
1. All units operational
-
2.Equipment room Temp ~25 Degrees C
-
3. No outstanding defects
-
Check external dampers on all buildings and structures
-
1. Damper winders operational
-
2. No outstanding defects
-
Check external units have physical protection from debris
-
Level of Protection
AC Power
-
Check AC supply mains point of connection
-
POI in good condition and adequately fixed Key Number
-
Check external light fittings
-
No loose fittings
Waste Management
-
Check cable chamber sump pump (s)
-
1. Pump (s) operate and discharge into waste system
-
2. Alarm signal to Telstra P&F
Emergency Power Plant (EPP)
-
Check EPP condition
-
Serviced within the last 12 months
-
No outstanding defects
-
Check operation
-
EPP run within last 3 months
-
No outstanding defects
-
Check Load
-
EPP can hold site load
-
No outstanding defects
-
Check EPP Alarms
-
All critical alarms active
-
Check MEPP/PEPP inlet or link box
-
Tested within the last 12 months
-
No outstanding defects
-
Check MEPP/ link cable is available on site
-
Adequate sized cable and associated connections available
-
Check accessibility to link box for locating MEPP if required
-
Adequate space available within 25M of link box for MEPP
Fuel Systems
-
Check fuel storage level
Adequate bulk fuel storage for EPP
P1 sites =>72 hrs + an allowance for testing
P2 sites =>24 hrs + an allowance for testing
P3 sites =>24 hrs + an allowance for testing
Adequate bulk fuel storage for constant run generator sites =>30 days -
Day/Belly Tank Levels
Day/Belly
-
Remaining fuel level
-
Bulk Tank Levels
Bulk Tank
-
Remaining fuel level
-
Check quality of fuel
-
Less than 24 months old
-
Check fuel systems
-
Serviced within the last 12 months
-
Fuel system operates
-
No outstanding defects
-
Check Alarms
-
Low fuel alarm activates
-
Critical fuel alarm activates
-
No outstanding defects
Telepower
-
Check Power Systems
-
Are power systems N+1
-
No outstanding defects
-
Check condition of all batteries on site
-
VRLA batteries tested/inspected within the last 12 months
-
Flooded tested/inspected within the last 6 months
-
Greater than 80% maximum battery capacity
-
No outstanding defects
Alarms/Outstanding Faults
-
Check Alarms
-
All activated alarms confirmed with Telstra P&F
-
No outstanding defects
Tower
-
Check tower structure
-
No loose/damaged guy wires
-
No loose/damaged structure members
Solar Arrays
-
Check solar arrays
-
No missing/loose/damaged solar panels
-
No outstanding defects
-
Audit Signature