Pre line Audit
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
Untitled Page
-
Are windows installed and sealed?
-
Are front doors installed?
-
Do front doors require fire sealant?
-
Has fire sealant been installed correctly? (10mm max thickness)
-
Are margins around front doors acceptable?
-
Are all fire collars complete?
-
Have fire penetrations been tagged and recorded?
-
Has cavity inspection been completed and passed?
-
Has pre-line plumbing inspection been completed and passed?
-
Has framing inspection been completed and passed?
-
Is framing in correct location?
-
Is timber framing straight and plumb? (mark with dazzle areas that need planning or packing)
-
Is timber framing dry? (check bottom plates in bathroom areas)
-
Is timber nogging in correct location for range hood?
-
Is timber nogging in correct location for heat pump?
-
Is timber nogging in correct location for vanity?
-
Is timber nogging in correct location for towel rails? (for KO job 800mm and 1600mm)
-
Is timber nogging in correct location for toilet roll holder?
-
Is timber nogging in correct location for shower liner?
-
Is timber nogging in correct location for hot water cylinder strapping?
-
Is the vanity mirror rebated?
-
Has vanity mirror framed out at correct size?
-
Has ceiling hatch been framed out?
-
Is rondo installed?
-
Is rondo installed to correct heights?
-
Are ceiling diaphragms required / installed?
-
Are there any rondo seismic requirements?
-
Are plumbing locations correct? (check all wing backs in kitchen and bathroom)
-
Are all light switches in the correct location?
-
Do all flush boxes comply with Gib bracing?
-
Are all power points in correct locations? (check location of oven, fridge, range hood)
-
Are power points in wet area at correct distances from water supplies?
-
Are ceiling lights and cables in correct positions?
-
Is this a KO project?
-
Are power points at correct heights off the ground (500mm) and correct distances from internal corners (500mm)
-
3 power points to bedrooms?
-
3 power points in the kitchen?
-
1 socket in the hallway?
-
Bedroom heater power in correct location?
-
Has the correct insulation been installed and to a high standard? (no gaps around insulation, clean, and dry)
-
Have interior doors been installed?
-
Are doors fixed off correctly?
-
Are door margins acceptable?
-
Has Gib been measured?
-
Has Gib been delivered?
-
Are units clean and swept out ready for Gib fixers?