The following checks on the intruder/hold-up alarm installation have been completed in accordance with BS 9263 2016.
-
Installation meets the ‘as fitted’ document
-
Tamper detection NOTE Check at least one tamper for correct operation through to the CIE.<br>
-
Setting and unsetting <br>NOTE Offer user(s) refresher system operation training, if required.<br>
-
Entry and exit procedures
-
Power supplies, including any APS.<br>(Testing of batteries and current readings)<br>Quiescent Current _________________mA<br>Alarm Current _________________mA<br><br>Battery Calculations to verify suitability.<br>Q x 11.5 + A x 0.5 = _________ x 1.25 = _________ C Min. <br><br>Battery Fitted ________ah - Suitable YES/NO <br>
-
Functioning of detectors and HD’s<br>(Full Walk test of system, Test PA buttons in normal Day Mode)<br>
-
Environmental conditions for adverse effects<br>(Check all detection is not damaged by water ingress or blocked)<br>
-
Operation of warning devices<br>(including removal of the hold off voltage to the external sounder, this should operate the unit until the hold off supply is restored)<br>
-
Operation of warning devices (including removal of the hold off voltage to the external sounder, this should operate the unit until the hold off supply is restored)
- 1-2
- 3-4
- 5-6
- 7-8
- 9-10
- 11-12
- 13-14
- 15-16
-
Visual inspection for potential problems <br>(electrical and physical)
Untitled page
-
Engineer comments:
-
Additional work required
-
Details of any work required
-
Engineer signature
-
Customer signature