Title Page

  • What is this document?

  • Conducted on

  • Checked by

  • Location

  • Where are you? and please bring the gantry back!

  • Model - Reids Porta Gantry
    Serial No. 1701-30455, 30461, 30478

  • Winch - Yale Electric Hoist
    Serial no - A6120

  • SWL (Safe Working Load) - 1000kgs

  • First part of inspection can be carried out
    with power off or on.
    These are just visual checks only.

  • Is the LOLER certificate for the Gantry in date?

  • What date does it expire?

  • When did it expire?

  • Pause inspection and report the issue

  • Is the LOLER certificate for the Winch in date?

  • What date does it expire?

  • When did it expire?

  • Pause inspection and report the issue

  • What condition are the wheels?

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check condition of Support Structure <br>(No damage, dents, etc)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Power Cables and guides<br>(No nicks, splits, broken connectors)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Main trolley beam <br>(straightness, damage, & end stops)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Main and Auxillary isolator switch <br>(damage, accessibility – i.e. can you reach / press it)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Pendant Control. <br>(Damage, Strain relief)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Hook and block <br>(Damage, bends)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Hoist Chain – (Damage, oil leaks)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Check Trolley<br>(Damage, oil leaks)

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

Operational Checks - Using the pendant controls

  • Test Up and Down Controls<br>Smooth operations, different speeds dependent on button pressure.

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Test Left and Right Controls

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

  • Test Hoist limit switch (top only)<br>hoist cut off when it reaches upper limit

  • What is the issue/s? Add photo/s to illustrate. Pause inspection and report findings.

Lifting Equipment Checks

  • Check the Synthetic Slings <br>(good condition, In date)

  • Fit "Do Not Use labels" and quarantine the slings.

  • Do we have other slings that are in good conditions and in date?

  • Then use the ones that are OK to use.

  • Pause inspection and report findings

  • Check Shackles, Eyebolts <br>(good condition, In date)

  • Fit "Do Not Use labels" and quarantine the offending shackles and/or eyebolts

  • Do we have other eyebolts and/or shackles that are in good condition and are in date?

  • Then use them.

  • Pause inspection and report findings.

  • Check Spreader bar<br>(good condition, In date)

  • Fit "Do Not Use labels" and quarantine the spreader bar

  • Can you use longer slings to avoid requiring the spreader bar?

  • THEN DO THIS

  • Pause Inspection and report findings.

  • Operators Signature Name not required just signature.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.