Title Page
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Supervision
-
FALL HAZARDS
-
GENERAL FALLS
-
Floor openings covered/guard rails in place?
-
Roof edge adequately guarded?
-
All horizontal lifelines engineered?
-
Leading edge protection and signage in place?
-
PFA's worn properly, 100% protection, inspected?
-
Employee's protected from fall exposures 6+ feet?
-
LADDERS
-
Secured at top and bottom?
-
Extended 36" above landing?
-
Rails and rungs in good repair?
-
Step ladder in good repair, used properly?
-
STAIRS
-
Stairways clear from tripping hazards?
-
Metal pans poured, filled, or barricaded from use?
-
Handrails installed on stairways and landings?
-
SCAFFOLDING
-
Scaffolding inspected?
-
Scaffolding plumb?
-
Scaffolding tied at 4x the base dimension?
-
Mud sills provided?
-
Guard rails, mid-rails, toe boards, and feet installed?
-
Fully planked?
-
Power lines inactive, removed or at a safe distance (20' from scaffold)
-
AERIAL LIFTS/MAN LIFTS
-
Tied off in articulating boom lift?
-
Chain closed on scissor lift?
-
Training verified? Being operated safely?
-
Power lines safe or at a safe distance (20+ feet)?
-
Protection from drop offs and holes?
-
CAUGHT IN-BETWEEN
-
EXCAVATIONS
-
Written daily inspections done by Competent Person?
-
Shored, sloped, or benched 1.5:1 unless can prove better soil type?
-
Tabulated data on site?
-
Slope toe is 18" below trench box?
-
Trench box max 2, above bottom of trench?
-
Trench boxes not damaged or missing parts?
-
Excavation is barricaded?
-
Spoil pile is 2' away from edge?
-
Exit for employees - ramp or ladder within 25'?
-
Underground locate performed prior to digging?
-
Equipment parked min. 20' from excavation?
-
ELECTRICUTION
-
GENERAL ELECTRICAL HAZARDS
-
Temp. Electrical has GFCI, proper installation?
-
Cords not in doors or blocking access?
-
Cords are free from damage?
-
Lock out/tag out procedures in place?
-
Terminal boxes equipped with covers
-
Power lines at a safe distance (20+ feet)?
-
STRUCK BY
-
EQUIPMENT SAFETY
-
Lights, brakes, horn, and back up alarm operative?
-
Inspection and maintenance logs current?
-
Fire extinguisher installed?
-
Seat belts being worn?
-
Safe speeds, controlled motion?
-
Employees wearing vests?
-
Rigging inspected, safely configured, tagged?
-
CRANES
-
Outriggers fully extended; proper cribbing?
-
Power lines at a safe distance (20+ feet)?
-
Inspection and maintenance logs current?
-
Signalmen? Proper hand/verbal signals being used?
-
Load charts posted in the cab?
-
Operator trained?
-
Fire extinguisher installed?
-
FLAGGING
-
Trained flaggers utilizing proper signage and PPE?
-
STEEL ERECTION
-
Erection floor solidly planked or decked?
-
Other trades protected from overhead hazards?
-
Tag lines being used?
-
Rigging inspected, safely configured, and tagged?
-
Employees using fall protection? Secondary fall protection as needed?
-
CONCRETE AND MASONRY
-
Vertically protruding rebar capped?
-
Forms properly installed and braced?
-
Route planned for concrete trucks?
-
Silica controls - water, vacuum tools, etc. (No dry cutting of concrete allowed)
-
Masonry walls over 8' adequately braced?
-
Eye protection (Glasses and face shield) gloves and boots when cutting and/or grinding?
-
OTHER HAZARDS
-
CONFINED SPACE
-
Manhole air quality is tested before entry?
-
Manholes are ventilated/blowers used before and during work, especially in shot rock areas?
-
Purge with air at least 5 minutes before entry?
-
No employees in manhole during stack out?
-
PROTECTION OF THE PUBLIC
-
Roads, sidewalk, public access areas safe?
-
HOUSEKEEPING
-
Jobsite entrances are clean and in good order?
-
OTHER
-
SDS book is on site?
-
Jobsite required posters?
-
First-aid kit is stocked, nearest clinic identified?
-
Emergency action plan shared?
-
Fire extinguishers are onsite? (One for every 3,000 SF min.)
-
Drinking water is available?
-
Toilets are maintained?
-
Fuel storage bermed/protected; 20lb fire extinguisher between 25'-75' (min./max)
-
PM Signature
-
Superintendent Signature
-