FUEL BURNING APPLIANCES AND EQUIPMENT - Furnaces, Boilers, Water Heaters, Kerosene Heaters, Space Heaters, Dryers, Fireplaces
Venting of Exhaust Gases
-
Outdoors away from intakes and windows
-
Traducción al español
-
Chimney and flue constructed and installed properly (per manufacturer))
-
Traducción al español
-
Chimney and flue inspected annually and cleaning
-
Traducción al español
Combustion Air
-
Adequate combustion air ducted to unit or
-
Unobstructed area large enough to provide adequate combustion air
-
Small mechanical areas have sufficient combustion air and ventilation openings
-
No hazardous or flammable vapor sources near combustion equipment
-
Traducción al español
Operation and Maintenance
-
Instructions available for proper operation and maintenance
-
Traducción al español
-
Equipment operated and maintained as intended within design limits
-
Traducción al español
-
Warning labels (English and local language) present on combustion appliances
-
Traducción al español
Clearance to Combustibles
-
Adequate clearance from exhaust flue to combustible materials
-
Adequate clearance from equipment to combustible materials
-
Boiler and furnace rooms not used for storage areas
-
Traducción al español
Fuel Type and Storage
-
Fuel used is appropriate for appliance(s)<br>
-
Proper type and location of fuel storage container (including tanks)
-
Protect fuel storage containers from damage and secure them for protection against weapons of opportunity
-
Traducción al español
Carbon Monoxide Alarms
-
Carbon monoxide alarm installed, at about eye level, outside of sleeping areas (including household staff) in residences with any combustion appliance (other than cooking oven/stove) or an attached garage
-
Traducción al español
Generators
-
Generator
-
Adequate space and, if leases, landlord agrees to the generator
-
Placed outdoors as far away as practical and a minimum of 1.5 meters (5 feet) from any building
-
Exhaust outlets >= 3 feet from exterior wall and roofs, 10 feet from operable opening into buildings, and 10 feet above adjoining grade
-
If distance and direction of exhaust is not feasible, then extend 3 ft. above the building. (See "Venting of Exhaust Gases" section)
-
Traducción al español
Portable kerosene heaters
-
Portable kerosene heaters
-
Single family home use only
-
Correct grade of kerosene (K-1) fuel stored outside in safety cans
-
Refuel outdoors away from sources of ignition, and after the heater has cooled completely
-
Set the wick height to the manufacturer's recommended level
-
Chimney is seated properly
-
Window opened slightly (e.g., 25mm/1 inch) in the room with the heater
-
Do not leave the heater unattended and turn off before going to bed
-
Keep the heater at least 1m (3 ft.) from combustibles unit is operated and maintained according to the manufacturer's instruction and residents are informed of the instructions
-
Carbon monoxide alarms must be placed in dwelling
-
Traducción al español
NATURAL AND LP GAS APPLIANCES AND EQUIPMENT
Cylinders during use:
-
- must be located on the exterior of the building
-
- equipped with a pressure regulator having a pressure relief valve
-
- upright and securely anchor or chained in place
-
- at least 7.6 m (25 ft.) from sources of ignition and 1.5 m (5 ft.) from building openings
-
Traducción al español
Cylinder storage
-
- outside within a fenced enclosure
-
- outlet valves close with cap or cover
-
- steel posts or barriers if vehicle damage is possible
-
- "No Smoking" signs clearly displayed around the storage enclosure with universal symbols or local language and English
-
- secure tanks to ensure they cannot be used as weapons of opportunity
-
Refilled tanks or bottles delivered, no recharging or filling of tanks or bottles at the site
-
Trained employees for LPG installation and cylinder replacement
-
Traducción al español
All Gas Service
-
Supply through rigid pipe (iron or steel), or tubing (steel, brass or copper)
-
- exceptions for seismically active areas-see Seismic Safety
-
Manual shut-off valve within 1.8 m (6 ft.) of appliance
-
Traducción al español
-
Leak detection using soapy water or other means must be conducted over all fittings and connections during cylinder or appliance replacement or anytime supply line work is done
-
Traducción al español
FIRE AND LIFE SAFETY
Emergency egress
-
Adequate emergency egress can vary with the type of building. Consult the Fire Protection Guide (FPG) for guidance
-
Traducción al español
Maximum Travel Distance to an Exit
-
Without automatic sprinkler protection: 150 ft. (45.8 m)
-
Automatic sprinkler protection: 200 ft. (61 m)
-
Traducción al español
High Rise Matrix
-
Is this an apartment building?
-
Stairs: 2 Exit Stairs Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: --- Real Estate Decision: Lease on any floor Stairs: 2 Exit Stairs Fire Alarm/Detection System: Full Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Lease at or below 5th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: Only 2 per floor Real Estate Decision: Lease at or below 6th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: More than 2 per floor Real Estate Decision: Lease at or below 4th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Lease at or below 3rd floor Stairs: 1 Exit Stair Fire Alarm/Detection System: None Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Do not lease
-
Traducción al español
Smoke Alarms (updated 2013)
-
Each sleeping room
-
Corridor leading to bedrooms
-
Top of internal stairwells on each floor level
-
Placement should be on the ceiling, or alternately on a wall between 4" (10 cm) to 12" (30.5 cm) away from the ceiling
-
Check detectors monthly for proper operation
-
Traducción al español
Portable Fire Extinguishers
-
One department standard 10 lb. (4.45 kg) extinguisher (4-A:40-B:C)
-
Wall mounted in or near each kitchen
-
Traducción al español
Alarm Systems
-
Does the property have an alarm system?
-
Several factors influence automatic fire alarm detection and/or automatic suppression system requirements
-
Consult the Fire Protection Guide (FPG) and contact OBO/OPS/FIR
-
Traducción al español
Lighting
-
Is this an apartment building?
-
Apartment buildings or congregate residences with 10 or more occupants: public space, hallway, stairway or other means of egress must have illumination of 1 foot candle power at floor level by emergency lighting
-
If emergency generator is not able to provide emergency lighting, provide battery-packed emergency lights in public spaces, hallway stairway or other means of egress
-
Installed and maintained correctly
-
Traducción al español
Exit Signs
-
Is this an apartment building?
-
- Illuminated exit signs
-
- directional signs if path is not straight or the exit is less than obvious
-
Traducción al español
Window Grilles
-
Are grilles installed?
-
Operable from the inside
-
Minimum opening: 5.7 ft. squared (0.529 meters squared)<br>
-
Minimum dimension: 24" (61 cm) x 20" (51 cm) and not be more than 44" (112 cm) from the floor
-
Bars or grilles must have inside release mechanism
-
Traducción al español
WATER HEATER PROTECTION (Temperature and Pressure Relief Valves )
-
Separate temperature and pressure relief valves (PRV and TRV) or combination temperature and pressure relief valves (TPRV) installed
-
TPRV drain piping installed to direct discharge floor
-
TPRV drain piping is not reduced, threaded at the end and has no uphill runs
-
TPRV drain piping has no other valve downstream of TPRV
-
Water temperature is not above 120 degrees F (49 degrees C)
-
Traducción al español
PLATE GLASS SAFETY (Tempered/Safety Glass Locations )
-
Entry and exit doors, storm doors, glass sliding doors
-
Windows located within 18" (46 cm) of the floor
-
Doors and enclosures for bathtubs, showers, sauna
-
Stairway enclosures and handrail panels
-
Locations listed above without tempered glass, need safety glass or non-breakable replacement materials, or protection with barriers. Doors at ground level may be treated with a Mylar coating or with decals or markings
-
Traducción al español
ELECTRICAL
Ground Fault Circuit Interrupters
-
Installed for wet locations (indoors and outdoors) and all kitchen countertop outlets at the outlet or the circuit breaker:
-
- 110-volt systems, installed GFCIs trip at 4 to 6 mA
-
- 220-volt systems, installed GFCIs trip at 10 mA
-
Do not install outlets where local code prohibits them in certain wet locations
-
Traducción al español
Grounding (Updated 2013)
-
An effective grounding system for a typical apartment or house includes a grounding electrode conductor (GEC) to connect the main service ground terminal to a grounding electrode system. Impedance of the ground path for any made electrodes may not exceed 25 ohms, as measured using the 3 terminal resistance measurement method and an earth electrode tester. <br><br>Verify and if missing, contact the FIR/FAC Help Desk via e-mail ( obo@cesengineers.com ) or call 866-949-6751 for assistance with grounding system installation
-
Grounding Ohms value
-
Traducción al español
Electric Service Supply & Panels
-
Missing knock-outs and twist-outs in beaker/fuse panel(s) must have fill plates
-
Traducción al español
-
Breaker/fuse panel front working clearance of 30" (76 cm) wide x 36" (92 cm) deep
-
Traducción al español
-
Breaker and fuses labeled as to function/area served
-
Traducción al español
-
Any outdoor service entrance, outlets and switch boxes have waterproof covers
-
Traducción al español
Circuit Capacity
-
Review usage and capacity and avoid excessive electrical loads. Verify that the following most commonly used branch circuit connectors in residences are protected by fuses or circuit breakers having trip elements not larger than:<br><br>Wires (Comparable U.S. Wire Size): Trip Setting:<br>1.5 mm squared (smaller than #14 AWG, 15A) 10A<br>2.5 mm squared (smaller than #12 AWG, 20A) 16A<br>4 mm squared (smaller than #10 AWG, 30A) 25A<br>6 mm squared (smaller than #8 AWG, 50A) 40A<br>10 mm squared (smaller than #6 AWG, 65A) 50A<br>16 mm squared (smaller than #4 AWG, 85A). 60A
-
Traducción al español
FALL PROTECTION
Railings
-
Are railings existing or required to be installed?
-
Installed on all railings porches, balconies and raised floor surfaces more than 30" (76 cm) above the floor or grade below <br>
-
Sturdy supports (balusters) with no openings larger than 4" (10 cm) and bottom of railing assembly no more than 4" (10 cm) from the floor
-
Top of railing is 42" (107 cm) or more from floor or grade level
-
Traducción al español
Stairs and Handrails
-
Are the stairs and handrails?
-
Installation of handrails, typically for stairways, at 34-38 inches and guardrails at a minimum height of 36 inches (42 inches is recommended) for balconies, decks, elevated patios, and other similar structures for family and duplex housing units. Guardrail installation at apartments and representational areas open to the public must be 42 inches high. Guardrails are required where the fall would be greater than 30 inches and must not have openings of greater than 4 inches
-
Steps have evenly-spaced risers
-
Any open risers between steps do not have an opening larger than 4" (10 cm)
-
Where there are 4 or more risers (steps), at least one handrail installed (right-side descending preferred) for any enclosed stairway. For stairs open on one or both sides, a handrail is installed on the open side(s). Installed handrails are 34-38" (86 cm) from the top of the stair tread nosing and can withstand a force of 200 lbs. (91 kg) in any direction
-
For open stairways, supports (balusters) no more than 4" (10 cm) apart
-
Traducción al español
Homes with Small Children
-
Latching device on windows allows opening no more than 4-5" (10-13 cm), but windows remains operable
-
Furniture away from windows and railings
-
Traducción al español
SWIMMING POOLS (Barrier and Safety Equipment (Updated 2013))
-
Is there a swimming pool in the complex?
-
A non-claimable isolation barrier (fence, wall, etc.) 4 ft. (122 cm) minimum height surrounding the pool that prevents direct access from living areas and excludes ancillary activities (e.g., barbecues, bars, ping pong tables)
-
Traducción al español
-
Self-closing, self-latching, lockable hardware on all access points (gates/doors) with latches at 54" (137 cm)
-
Traducción al español
-
Rescue equipment available (shepherd's crook, poles, ring buoy) and in plain view
-
Traducción al español
-
Depth markings and no divining indicated and safety rules posted community use pools and residential use pools that are used as community use pools, i.e., CMR, MSGR
-
Traducción al español
-
First aid kits and emergency communication means for community use pools and residential use pools that are used as community use pools
-
Traducción al español
-
Outlets equipped with Ground Fault Circuit Interrupters (GFCI) and covers
-
Traducción al español
-
Pools chemicals stores separate form other materials in a cool, dry, ventilated area with restricted access
-
Traducción al español
ELEVATORS
-
Is there an elevator?
Elevator Lobby & Car
-
All elevator cars have functional doors independent of shaft doors
-
Elevator doors (car & shaft) reverse direction when an object is either contacted by the leading edge of the door or detected by an electronic door protection device
-
All external car operating features, lobby controls and hardware are intact and function properly
-
Car operating buttons, including the emergency alarm button, function properly
-
Car lights are on and bulbs or tubes are secure
-
Car service panel is locked
-
Car emergency phone is connected to a 24-hour operator
-
Car's audible signals are operating
-
All door mechanisms are enclosed to avoid pinch/shear points
-
Traducción al español
Machine Room & Maintenance
-
Machine room access door is locked and keys stored securely
-
Good housekeeping, no trash, not being used as a storage area, no excessive oil leaks, control cabinet(s) intact
-
Illumination is adequate to perform inspection
-
ABC fire extinguisher located in machine room
-
Temperature is not above 120 degrees F (49 degrees C)
-
Elevator is under a service contract and service logbook is utilized and up to date
-
Elevator has a current safety certificate
-
Traducción al español
ENVIRONMENTAL
Asbestos
-
Asbestos detected?
-
Acquisitions: asbestos inspection conducted and impact of asbestos determined
-
Asbestos materials identified and maintained in good condition
-
Maintenance and minor renovations avoid disturbance of asbestos materials
-
If asbestos material is to be disturbed, it is removed properly and records of removal and disposal are maintained
-
Traducción al español
Leaded Paint
-
Only lead-free paint is applied
-
Paint in good condition with minimal damage
-
Paint sampled prior to renovation or major maintenance work
-
Leaded paint removed prior to start of work or minimize disturbance
-
Traducción al español
Pesticides
-
Building conditions or location not inviting to common local pests
-
No history of chronic pest problems or extensive pesticide use
-
Willing and capable to implement Integrated Pest Management (IPM) program in USG occupied space
-
Pest control measures to reduce pest habitats
-
Self-help measures to control pests (if control measures are not effective)
-
Apply pesticides listed in the IPM only as a last resort
-
Traducción al español
Drinking Water Quality
-
Tap water is potable (microbiologically safe and within acceptable contaminant levels listed in the Department's drinking water standards)
-
If tap water is not potable, then supplemental means (e.g., point of use device such as a distiller) are used to render the water potable and quality control monitoring is done
-
Traducción al español
SEISMIC ISSUES (FOR POSTS IN SEISMIC ZONES 2 OR HIGHER)
-
Avoid seismically unsafe structures
-
Propane tanks, kerosene heaters: use flexible connections to the tank and anchor storage tanks to the ground
-
- Water heaters, propane (LPG) gas cylinders and natural gas use flexible, metallic connections for water and gas lines
-
- Water heaters, propane (LPG) gas cylinders and natural gas use metal straps which are bolted using expansion bolts to a masonry wall, or lag bolts to a wood stud wall, at the top and bottom of the water heater and propane cylinders
-
Block in space between water heater and wall to prevent rocking tall, heavy furniture such as bookcases should be secured to prevent sliding or tipping, using L-brackets or other device and remove casters or wheels to prevent rolling
-
Check for weaknesses in chimneys such as damage or missing bricks and install plywood above ceiling joists to keep bricks from falling through
-
Ensure cabinet latches are strong enough, especially in the kitchen, to prevent contents from falling out; install safety latches for added security
-
Brace and bolt storage racks and shelves to the floor and walls and secure contents so they can't slide off
-
Traducción al español
WINDOWS' CORDS Blinds, curtains and shades
-
Cords must be separated and independent avoiding a continuous rope
-
A lock or butterfly type lock attached to the Wall is used to tie the cords to let them out of children reach
-
Tensors fixed to the floor or wall to avoid cords or chains to form a continuous rope.
-
Traducción al español
MARINE LADDER
-
Is there an adequate ladder to access the roof?
-
Cages or wells shall be provided on ladders of more than 20 feet (6m)
-
Access to marine ladder is limited.
-
Traducción al español
WATER STORAGE TANKS Cistern
-
Is the cistern cover locked with a padlock? <br>
-
Has the cistern manhole a built in frame barrier?
-
Cistern washing has been documented or recently made?
-
Traducción al español
LOCAL CONSIDERATIONS
-
Steam resistant lamps in all bathrooms shall be placed <br>
-
Traducción al español
-
30 A electrical outlet to electrical heaters per each bedroom.
-
Traducción al español
-
Is there a bathtub?
-
Place a handle to the bathtub
-
Traducción al español
-
Is there a chimney?
-
Perform and document maintenance of the chimney as required
-
Traducción al español
-
Have all fall or health hazards been avoided as possible?
-
Traducción al español