TITLE PAGE
TITLE PAGE
-
DOCUMENT NO.
-
CLIENT
-
PROJECT #:
-
DATE:
GENERAL INFORMATION
GENERAL INFORMATION
-
PROJECT:
-
JOB LOCATION:
-
WELL #:
-
WELL DEPTH (ft):
-
OPERATOR:
-
INSPECTOR:
-
PUMP TEST START TIME:
-
If the sanding rate exceeds the specifications, describe measures taken between tests. (This information can be entered into the Note box at the end of this form.)
-
The maximum allowable sanding rate is 1 pt / 25,000 gal ~ 5 ppm (parts per million).
-
Click the "Open Link" button to open a Technical Memorandum for Sand Infiltration Tests using the Rossum Tester.
http://roscoemoss.com/wp-content/uploads/techmemos/TechMemo005-7RossumTester_000.pdf
TEST # 1
TEST # 1
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST # 2
TEST # 2
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST # 3
TEST # 3
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST # 4
TEST # 4
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST# 5
TEST # 5
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST # 6
TEST # 6
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min):
-
SANDING RATE (ppm):
TEST # 7
TEST # 7
-
(CLOCK) TIME (min)
-
START:
-
STOP:
-
WELL FLOWMETER READING (gallons)
-
BEGIN:
-
END:
-
PUMPING RATE (gpm):
-
LENGTH OF TEST (min):
-
CONTAINER VOLUME (gallons):
-
TIME TO FILL (min):
-
OUTLET VALVE FLOW (gpm) (The outlet valve should be calibrated to 0.5 gpm.)
-
ROSSUM READING (ml)
-
START:
-
STOP:
-
SANDING RATE (ml/min)
-
SANDING RATE (ppm):
NOTES
NOTES
-
If sanding rate exceeds specifications, describe measures taken between tests.
PHOTOS
PHOTO DOCUMENTATION
-
Photo #1
-
Description of photo
-
Photo #2
-
Description of photo
-
Photo #3
-
Description of photo