Title Page

  • Site conducted

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Location

West Cyclone

Underflow

  • Is train 1 in use?

  • Is the seal water to train 1 open or closed?

  • Is the process water to train 1 open or closed?

  • Is the rupture disk on train 1 operational?

  • Are the pumps, valves and piping in good condition?

  • Is train 2 in use?

  • Is the seal water to train 2 open or closed?

  • Is the process water to train 2 open or closed?

  • Is the rupture disk on train 2 operational?

  • Are the pumps, valves and piping in good condition?

  • Is train 3 in use?

  • Is the seal water to train 3 open or closed?

  • Is the process water to train 3 open or closed?

  • Is the rupture disk on train 3 operational?

  • Are the pumps, valves and piping in good condition?

Overflow

  • Is PP-150 in use?

  • Is the seal water to PP-150 open or closed?

  • Is the process water to PP-150 open or closed?

  • Is PP-150, valves and piping in good condition?

  • Is the valves & piping around the Overflow Sump in good condition?

  • Are the rupture disks on the over flow system operational?

Seal Water

  • Is PP-250 in use?

  • Is PP-250, valves and piping in good condition?

  • Is PP-251 in use?

  • Is PP-251, valves and piping in good condition?

  • Did you clean the duplex filters ?

  • What is the seal water pressure from the discharge of the duplex filter (PI-179)

  • Is duplex filters, valves and piping in good condition?

  • Is LV-290 in use?

  • Is LV-290, seal water tank and piping in good condition?

Feed Sump

  • Is SPD Pump-101 in use?

  • Is the seal water to PP-101 open or closed?

  • Is the suction valve XV-121A open or closed?

  • Is the process water valve XV-121C open or closed?

  • Is the discharge valve XV-121B open or closed?

  • Is SPD Pump-101's valves and piping in good condition?

  • Is SPD Pump-104 in Use?

  • Is the seal water to PP-104 open or closed?

  • Is the suction valve XV-124A open or closed?

  • Is the process water valve XV-124C open or closed?

  • Is the discharge valve XV-124B open or closed?

  • Is SPD Pump-104's valves and piping in good condition?

  • Is PP-102 in use?

  • Is the seal water to PP-102 open or closed?

  • Is the process water to PP-102 open or closed?

  • Is PP-102, valves and piping in good condition?

  • Is the cyclone 102 and piping in good condition?

  • Is the process water to CYC-102 open or closed?

  • Is PP-103 in use?

  • Is the seal water to PP-103 open or closed?

  • Is the process water to PP-103 open or closed?

  • Is PP-103, valves and piping in good condition?

  • Is the cyclone 103 and piping in good condition?

  • Is the process water to CYC-103 open or closed?

Choke Station

  • Is XV-113A in use?

  • Is XV-113B in use?

  • Is XV-113C in use?

  • Are the rupture disks for the Choke Station operational?

  • Is the Choke Station piping in good condition?

Miscellaneous

  • Is the heat trace and insulation in good condition?

  • Did you clean the air compressor's air filters?

  • Is the house keeping good?

  • Are there any safety issues or problems with the West Cyclone or the Feed Building?

  • Operator

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.