Title Page
-
Conducted on
-
Prepared by
-
Location
-
Scaffold Supplier
-
Photo of Scaffold
Base
-
Does the base need inspecting at this audit?
-
Is the scaffold on a solid base?
-
Does each standard have a base plate?
-
Are sole plates of correct dimensions being used?
-
Is the sole plate on solid ground?
Geometry
-
Does the geometry want inspecting at this audit
-
Are the standards vertical?
-
Are the ledgers and transoms horizontal?
-
Are the ledger and/or standard joints no more than 1/3 into the bay?
-
Are the transoms correctly spaced?
-
Are the clamps within 300mm of the node?
-
Do the transoms pretrude a minimum 50mm?
Bracing
-
Does the bracing want inspecting at this audit?
-
Is the ledger bracing fitted on alternate pairs of standards for the full height of the scaffold?
-
Is the ledger bracing fitted to every other bay?
-
Is the facade bracing fixed to every lift?
-
Is the facade bracing fitted along the face of the scaffold at least every 5 bays?
-
Is the facade bracing set at between 35 and 55 degrees?
Tubes and Fittings
-
Do the tubes and fittings need inspecting at this audit?
-
Are the tubes and fittings used in good condition (rust free)?
-
Have the correct couplers been used?
-
Are all fittings tightened sufficiently?
-
Are check couplers fitted as required?
Access
-
Does the access need inspecting at this audit?
-
Is access provided to full height of the scaffold?
-
Is the ladder at a slope of 75 degrees or 1:4 ratio base to height?
-
Is the head securely tied and feet on a firm and level base?
-
Do the ladders rise at least 1.05m (3 rungs) above each platform?
-
Are the ladders undamaged?
Platforms
-
Do the platforms want inspecting at this audit?
-
Are the supports/transoms correct and evenly distributed?
-
Is the overhang a minimum of 50mm (max 150mm)?
-
Are the boards sound? (No nothched or cut boards)
-
Are board ends strapped?
-
Are lapped boards safe?
-
Are the boards secure? (Tied)
-
Is the gap from board to wall within 225mm?
Guard Rails and Toe Boards
-
Do the guard rails and toe boards need inspecting at this audit?
-
Are the guard rails secured to the inside of the standards?
-
Are guard rails fixed at least 950mm above the level of the platform?
-
Is intermediate side protection provided so that there is no vertical gap exceeding 470mm
-
Are toe boards fitted to all platforms and at least 150mm high?
-
Are the toe boards secured to the inside of the standard?
Loading and loading bays?
-
Do the loading bays and loading of materials need inspecting at this audit?
-
Is the erected scaffold correct for its intended use?
-
Is there a loading bay?
-
Is it fit for purpose?
-
Does it have the correct guards/gates?
-
Is it loaded within the load limits?
-
Are the loads on the platform evenly distributed?
-
Are stacked materials secure?
Ties
-
Do the ties need to be inspected at this audit? (Only inspect if ties are present)
-
Have sufficent ties been used in accordance with current regulations?
-
Are ties fixed with right angle couplers?
-
Are ties attached to both inner and outer standards or ledger?
Scafftag
-
Does the scafftag need inspecting at this audit?
-
Is the scafftag prominently displayed at all access points?
-
Have the details of the scafftag been completed correctly?
-
Have the inspections been written in and signed by an authorised person?
-
Are the inspection frequencies in accordance with the regulations?
General Comments
-
Any further comments or recommendations arising from this inspection?
-
Comment:
-
Add any additional relevant photos
-
Have all required corrective actions been added as Actions to this inspection?
-
Please add any corrective actions to the appropriate questions above before completing this report
Sign Off
-
Add photo of signed scafftag
-
Name & Signature of Inspector