Scaffolding Safety Inspection
General Information
-
Type of scaffolding
- Trestle
- Steel
- Patented
- Suspended
- Cantilever
- Single
- Double
- Kwikstage
-
Description of work
-
Take a photo of it
Base
-
Is the scaffold on a solid base?
-
REFERENCE: Good example of scaffold on a solid base
[This is an example of how you can use iAuditor to include best practice reference images in your templates to assist with inspections]
undefined
-
-
Does each stand have a base plate?
-
Are sole plates of the correct dimension being used?
Height
-
Are free-standing tower scaffold steadied with guy wire according to regulations requirements for its height?
-
Are safety cage needed around vertical ladder based on height according to regulatory requirements?
-
Are perimeter placed on work surfaces (toe board permanent and temporary height) according to regulatory requirements?
-
Are perimeter handrail height with a mid-rail around all work platforms according to regulatory requirements?
-
Are rolling scaffold wheel brakes locked and outriggers extended to maintain maximum height of 3 times the smallest base dimension?
-
Are toprail based on height according to regulatory requirements?
-
Are midrails installed approximately halfway between the toprail and the platform surface
Geometry
-
Are the standards vertical?
-
Are the ledgers and transoms horizontal?
-
Are the joints in the standards staggered?
-
Are the joints in the ledgers staggered?
-
Are the transoms correctly spaced?
Platforms
-
Are the supports correctly and evenly distributed?
-
Are the overhang has the minimum standard size?
-
Does the board doesn't have creaky sound?
-
Are lapped boards safe?
-
Are boards secure?
Bracing
-
Is the ledger bracing fitted on alternate pairs of standards for the full height of the scaffold?
-
Is the façade bracing fixed to every lift?
-
Is the façade bracing fixed to the face of the scaffold at standard intervals?
-
Is the façade bracing set at standard angle
Tubes and Fittings
-
Are the tubes and fittings used in good condition?
-
Have the correct couplers been used?
-
Are all fittings tightened sufficiently?
-
Are check couplers fitted as required?
Access
-
Is access provided to the full height of the scaffold?
-
Is the ladders positioned at standard angle?
-
Is the head tied and the feet on a firm base?
-
Do ladders rise in standard height above platforms?
Loading
-
Is the scaffold correct for its intended use?
-
Are loads on the scaffold evenly distributed?
-
Are stacked materials secure?
Ties
-
Are sufficient ties used in accordance with safety regulation?
-
Are ties fixed with a double coupler?
-
Are ties fixed on both inner and outer ledgers or standards?
Guard Rails and Toe Boards
-
Are the rails fixed at least 950mm above the platform?
-
Is the rail fixed a maximum of 470mm above the toe board?
-
Are toe boards fitted to all platforms and at least 150mm and secure?
Scaffolds Tag
-
Is the scaffolding tag displayed at the access point?
-
Has the front of the scaffolding tag been completed correctly?
-
Have the inspections been written in and signed by the authorized person?
-
Are the inspection frequencies in accordance with the standard regulations?
Recommendation
-
Overall Ranking
-
Recommended scaffolding tag
-
Recommendations or other requirements
Completion
-
Inspector's Name and Signature