Information

  • Conducted on

  • Location

1.0 - Previous Inspection

  • 1.1 - Has The Last Inspection Been Reviewed?

  • 1.2 - Are There Any Outstanding Actions?

2.0 - General Condition

  • 2.1 - Is the OSHA poster up to date? Standard 1910.2

  • 2.4 - Is the entrance to the yard and office clean and tidy? Company Standard

  • 2.5 - Are aisles marked and kept clear? Standard 1910.22 (b)(2) & (a)(1)

  • 2.6 - Are materials in process and finished product neatly stored? Standard 1910.141 (a)(3)

  • 2.7 - Are rubbish containers provided and used (waste baskets in a safe position)? Standard 1910.141 (a)(4)

  • 2.8 - Is lighting and ventilation adequate for intended process? Standard 1910.94

  • 2.9 - Is the overall condition of the building and maintenance good? Company Standard

  • 2.10 - Are the clean up procedures adequate? Standard 1910.22(a)(1)

  • 2.12 - Is good house keeping maintained? Standard 1910.22(a)(1)

  • 2.13 - Are new employees trained on safety procedures? Standard 1910.508 (a)(2)

  • 2.14 - Is the Storm Water Plan available, and current? EPA Standard

  • 2.15 - Is the shop and yard free of oil stains. EPA Standard

3.0 - Machinery

  • 3.1 - Are machines kept clean? Company Standard

  • 3.2 - Is machine area kept clear of obstructions? Standard 1910.22(a)(2)

  • 3.3 - Are machine guards in place on all grinders, saws, etc., and in good condition? Standard 1910.212

  • 3.4 - Are repairs or adjustments prohibited while operating machine? Standard 1910.213(b)(5)

  • 3.5 - Do only authorized personnel operate equipment? Company Standard

  • 3.6 - Do machine operators wear proper clothing? Standard 1910.132

  • 3.7 - Are potential hazards blocked with barriers to prevent injury? Standard 1910.212(a)(1)

  • 3.8 - Is compressed air used for cleaning reduced to 30 psi.? Standard 1910.242(b)

  • 3.9 - Is stationary machinery securely anchored to prevent moving? Standard 1910.212(b)

  • 3.11 - Are all powered and hand tools in good condition and free of defects? Standard 1910.242

  • 3.12 - Is cut-off waste removed and stored properly?

  • 3.13 - Are emergency shut off switches within easy reach of the operator? Standard 1910.(b)(1)

  • 3.14 - Are drip pans in place to prevent spills? IPS Standard

  • 3.15 - Is lighting adequate? Standard ANSI A11.1-65

  • 3.16 - Is noise level controlled? Standard 1910.95(b)(1) Table G-16

  • 3.17 - are gas bottles secured? NFPA 55-6.6

4.0 - Electrical

  • 4.1 - Are extension cords in good shape, grounding plug in place, insulation in good shape and free of any tape? Standard 1910.334(a)(2)(ii)

  • 4.2 - Is electrical wiring and equipment well supported and protected from mechanical wear? Standard 1910.334(a)(2)(I)

  • 4.4 - Any broken plugs, sockets, or switches? Standard 1910.334(a)(2)(ii)

  • 4.5 - Is fixed electrical equipment Grounded? Standard 1910.404(f)(1)(v)

  • 4.7 - Are inside breaker switches labeled? Standard 408.4(A)

  • 4.8 - Are all unused openings (including conduit knockouts) in electrical enclosures and fittings closed with appropriate covers, plugs or plates?<br>Standard NEC 110.12(A)<br>

  • 4.9 - Is access to control boxes kept clear? Minimum 36" in front of panels. Standard NEC 110.36

  • 4.11 - Do Ground-Fault Circuit Interrupters (GFCI's) pass first test using push button built into the outlet? Standard UL943-20.1

  • 4.12 - Are electrical receptacles located within 3 feet of a sink, exterior door, out door receptacles, and metal work surfaces equipped with GFCI's? Standard NEC 210.52(D)

  • 4.14 - Extension cords not hanging from metal structures; piping, nails, hooks, ladders, or scaffolds? Standard 1910.334(a)(1)

  • 4.15 - No extension cords pass through walls, ceilings, doors, or windows? Company Standard

  • 4.16 - Extension cords are not subject to vehicle traffic and/or equipment traffic? Company Standard

  • 4.17 - Are extension cords across walkways? Standard 1910.22(b)(1)

  • 4.18 - Are extension cords free of splices or tape? Standard 1926.405(g)(2)(iii)

  • 4.19 - Are portable power tools in good condition and grounded or of the double insulated type? Standard 1915.132(a)

  • 4.20 - are all recepticals labeled with the voltage? Standard NEC 406.12 & 406.4(D)(5)

5.0 - Fire Prevention and Flammable Materials

  • 5.1 - Are oxygen and acetylene bottles properly stored and chained? Standard 1910.253(b)(2)(ii)

  • 5.2 - Are compressed gas cylinders stored 20 ft. away from heat sources. Standard 1910.253(b)(4)(iii)

  • 5.3 - Are oxygen and acetylene stored 20 ft. apart or by a 5 ft. high, 1/2 hour rated firewall? Standard 1910.253(b)(4)(iii)

  • 5.4 - Are fire extinguishers clearly marked and easily accessible? Standard 1910.157(c)(1)

  • 5.5 - Are fire extinguishers checked by a third party annually and tagged? Standard 1910.157(e)(3)

  • 5.6 - Are extinguishers readily available near welding, painting, and oily clean up areas? Standard 1910.157(c)(1)

  • 5.7 - Are stored items kept from accumulation that could cause a hazard (i.e. tripping,fire,explosion or pest harborage)? Standard 1910.176(b)

  • 5.8 - Are "No Smoking" signs displayed and enforced in designated areas? Standard 1910.126(a)(3)

  • 5.10 - Are Flammables in approved flammable cabinets? Standard 1910.152(b)(2)(iii)

  • 5.12 - Are all soiled rags stored in approved metal containers with gravity type closing lids? Standard 1910.252(e)

  • 5.13 - Are fire exits kept clear, accessible and clearly marked? Standard 1910.37(a)(3) & 37(b)(2)

  • 5.14 - Do fire exits open easily from the inside? Standard 1910.36 (d)(1)

  • 5.15 - Are all doors marked with "exit" or "not an exit" signs? Standard 1910.37(b)(2) & 37(b)(5)

  • 5.16 - Are static discharge wires used when transferring flammables from one container to another? Standard 1910.106(e)(6)(iii)

  • 5.17 - Are attic and platform storage areas clean and free of trash? Standard 1910.176(b)

  • 5.18 - Are propane bottles stored outside, have identifying signs, and secure? Standard NFPA-58-8.4.1.2

6.0 - Material Handling and Storage

  • 6.1 - Are conveniently placed racks and bins for small parts provided? Company Standard

  • 6.3 - Is adequate clearance provided for material handling equipment and are clearance signs posted? Standard 1910.176(e)

  • 6.4 - Do lift trucks have rollover protection, canopy guard, horn, back up alarm, and proper lighting? Standard 1910.178(p)(1)

  • 6.5 - Are hand and powered trucks in good condition? Standard 1910.178(q)(1)

  • 6.6 - Are hazardous chemicals handled with proper PPE when required? Standard 1910.120 APP B

  • 6.7 - Do all employees use proper lifting methods? Company Standard

  • 6.8 - Are lift truck riding guidelines followed? Standard 1910.178(m)(2)

  • 6.9 - Are fork lift compressed gas cylinders inspected to insure they are in good condition? Standard 1910.101(a)

  • 6.11 - Are fork lift operators properly trained and records on file? Standard 1910.178(l)

7.0 - First Aid

  • 7.1 - Is a trained first aider available on site? Standard 1910.151(b)

  • 7.2 - Is first aid given promptly and by a first aider for minor injuries? Standard 1910.151(a)

  • 7.3 - Are company emergency numbers posted along with the incident reporting protocol map? Company Standard

  • 7.4 - Are CPR kits and barriers available? Standard 1910.1030(d)(3) & 1910.151(b)

  • 7.5 - Is there a practical first aid manual on location? Company Standard

  • 7.6 - Are special medical examinations current (i.e. Respirator or any examination that may be designated)? Standard 1910.134 APP. C

  • 7.7 - Are first aid cabinets and contents clean and orderly? Standard !910.266(d)(2)(iv)

  • 7.8 - Are contents regularly checked? Company Standard

  • 7.9 - Are cabinet clearly labeled? Company Standard

  • 7.10 - Are cabinets easily accessible? Company Standard

  • 7.11 - Are Biohazard kits available? Standard 1910.1030(d)(4)(iii)[B]

8.0 Safety Equipment

  • 8.1 - Is personal protective equipment maintained in a sanitary and reliable condition?

  • 8.2 - Is face and eye protection used when there is a reasonable probability of injury (i.e. welding, cutting, grinding, etc.)?

  • 8.4 - Is foot protection used when there is a probability of injury?

  • 8.5 - Is respiratory protection used where there is a danger from dust, fog fumes, smoke, vapors, etc.?

  • 8.6 - Are employees using hearing protection in required areas or when exposed to high levels of noise?

9.0 Walkways

  • 9.1 - Are isles and passageways kept clear? Standard 1910.22 ( a)(1)

  • 9.2 - Are isles and walkways marked? Standard 1910.22(b)(2)

  • 9.3 - Are wet floors covered with non-slip a material? Standard 1910.22(a)(2)

  • 9.4 - Are holes in the floor, sidewalk or other walking surfaces repaired properly, covered or otherwise made safe? Standard 1910.22(c)

  • 9.5 - Are materials or equipment stored in a such a way that sharp projectives will not interfere with the walkway? Standard 1910.22(a)(3)

  • 9.6 - Are spills cleaned up immediately?

  • 9.7 - Are changes in elevation readily identifiable?

10.0 - Stairs and Stairways

  • 10.1 - Are hand rails on stairs with 4 or more risers? Standard 1910.23(d)(1)

  • 10.4 - Are the steps designed or provided with a material that makes them slip resistant? Standard 1910.24 (f)

  • 10.5 - Are the handrails located between 30 and 34 inches above the leading edge of the stair tread? Standard 1910.23(e)(2)

11.0 - Hazard Communication

  • 11.1 - Is there a "Right to Know" station with a list of the chemicals in the workplace? Standard1910.1200(e)(1)(i)

  • 11.2 - I there a written hazard communication program? Standard 1910.1200(e)(1)

  • 11.3 - Are MSDS sheets readily available to employees? Standard 1910.1200(g)(8)

  • 11.4 - Is there an employee training program for hazardous substances? Standard 1910.1200(h)(3)

  • 11.6 - Are containers labeled properly? Standard 1910.1200(f)(9)

  • 11.7 - Do chemical storage areas have adequate containment? Standard EPA 40 CFR 264.175

  • 11.8 - Are eye wash stations easily accessible? Standard 1910.151(c)

13.0 - Outside - Environmental

  • 13.1 - Materials and stored equipment covered?

  • 13.2 - Drum storage area under cover?

  • 13.3 - All drums have plugs in holes?

  • 13.4 - Are empty drums stored on their sides so rain water can not collect in them?

  • 13.5 - Are empty drums disposed of in a timely manner?

  • 13.7 - Are surface areas clear of potential pollutants and oil stains?

  • 13.8 - Spill kits on site, stocked and ready for use?

  • 13.9 - Lids on dumpsters closed and in good condition?

  • 13.10 - Is metal dumpster free of material that are covered in oils or chemicals?

  • 13.11 - Is the wash bay free of garbage and debris?

Additional items

  • Add signature

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.