Title Page
-
Site conducted
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Previous Inspection
Previous Inspection
-
Date of last inspection:
-
Score:
-
Description of discrepancy:
-
Are there any outstanding actions?
LSR 1. Risk Assessment
LSR 1. Risk Assessment
-
Risk Assessment Audit Questions:
-
Is a Risk Assessment being completed?<br>
-
Is there evidence of T-5s or other forms of safety meetings being conducted and documentation made available?<br>
-
Are emergency phone numbers posted near all phones and kept up-to-date?<br>
-
Are SDSs up-to-date and readily available?<br>
-
Are first aid kits stocked with no expired products?<br>
-
Are first aid kits easily accessible?<br>
-
Is a trained first aider available on site?<br>
-
Are CRH Life Saving Rules posted?<br>
-
Are emergency lighting and exit signs routinely checked and properly maintained?<br>
-
Are all emergency exits in buildings properly identified?<br>
-
Are all emergency exits in buildings free of obstructions?<br>
LSR 9. Use of Personal Protective Equipment (PPE)
LSR 9. Use of Personal Protective Equipment (PPE)
-
PPE Audit Questions:
-
Are hard hats being used?
-
Are high visibility safety vests or shirts being worn?
-
Are safety glasses or goggles being used?
-
Are safety toe boots being worn?
-
Is hearing protection available and used when required?
-
Are proper gloves available and worn when required?
-
Are dust masks made readily available?
-
Are loose clothing, adornments, and hair suitably controlled/ confined to prevent entanglement with any machinery and device?
-
Are all PPE being worn in good condition?
-
Does the supervisor/foreman have extra PPE?
-
Is the appropriate PPE made available for welding?
Arch Flash Required PPE
-
Arch Flash PPE Audit Questions:
-
Is flash resistant clothing, coveralls or uniform in good condition and readily available?
-
Is Arch Flash hard hat with face shield in good condition and readily available?
-
Is adequate gloves made available with Arch Flash equipment in good condition?
-
Document date on gloves:
LSR 3. Isolation of Operating Machinery and Electrical Safety
LSR 3. Isolation of Operating Machinery and Electrical Safety
-
LOTO Audit Questions:
-
Is Lockout/ Tagout manual/ policy up-to-date and being used properly?<br>
-
Are valves covers and lockout equipment devices available?<br>
-
Does each employee have their own lock?<br>
Mobile Equipment During Maintenance
-
LOTO for Mobile Equipment
-
Are steering wheel covers and other lockout equipment devices available and being used?
-
Are wheel chocks and jack stands available and used?
LSR 3. Isolation of Operating Machinery and Electrical Safety
Electrical Safety
-
Electrical Audit Questions:
-
Is all of the electrical wiring free of damage and fray?<br>
-
Are extension cords in good condition?<br>
-
Are electrical equipment operating between 50 and 600 volts protected against accidental contact by an approved cabinet or other enclosure?
-
Are GFCI provided on outlets around water and all extension cords?<br>
-
Is there a 3-foot clearance around electrical boxes?<br>
-
Are all electrical panels, breakers and disconnect boxes identified properly with Arch Flash labels?<br>
-
Are disconnects labeled to show what they control?
-
Are permanent splices in cables insulated, in good condition, and sealed from moisture?<br>
-
Are electrical cords across walk-ways protected/covered?<br>
-
Is there permanent wiring used in place of extension cords?<br>
-
Are all electrical switches, breakers, etc. properly labeled with what they operate?<br>
-
Are the Motor Control Center (MCC) entrances clearly identified as DANGER and restricted to authorized personnel?<br>
-
Is there sufficient access and working space provided and maintained around all electrical equipment including access to disconnect devices?<br>
-
Are there no extraneous combustible/ flammable materials stored in MCC rooms?<br>
-
Are all cords of electrical operating tools connected and effectively grounded?
-
Are welding-leads free of damage and excessive repairs?
-
Are welding electrodes insulated and fully intact?
Fire Protection/ Prevention
Fire Protection/ Prevention
-
Fire Safety Audit Questions:
-
Are smoke detectors working properly?<br>
-
Are carbon monoxide detectors working properly, if applicable? Mechanic Shops, Offices Connected to Shops, Where Fuel Burners are used, etc.
-
Are fire extinguishers strategically located?<br>
-
Are all of the fire extinguishers visible and accessible?<br>
-
Do fuel dispensing areas have proper signage and adequate fire suppression readily available?<br>
-
Are monthly fire extinguisher inspections being logged?
-
Are "no smoking" signs/labels posted around flammable materials?<br>
-
Are flammable liquids stored in approved safety cans and containers?<br>
-
Are containers of flammable/combustible materials stored in a flammable storage cabinet or other isolated areas and proper signage in place?<br>
-
Are flammable storage areas vented properly?
-
Are spill kits/absorbent available?<br>
LSR 6. Working at Heights
LSR 6. Working at Heights
-
Working at Heights Audit Questions:
-
Is fall protection in good working condition?<br>
-
*Are employees/subcontractors working above 6 feet?<br>
-
Are employees/subcontractors equipped with adequate fall protection?<br>
-
Are all ramps bermed half the distance of the largest equipment being used on ramps?<br>
-
Are chains or self-closing gates in use at the top of all Fixed Vertical Ladders (FVLs)?<br>
-
Are all FVL more the 19 feet in length equipped with cage that extends at least 36 inches above the landing & starts not more than 7 feet from the bottom of the ladder, or are equipped with center-line fall protection?<br><br>
-
If an employee is working from heights, is the area below barricaded-off half the distance that they are working from?<br>
Ladder Safety
-
Ladder Safety Audit Questions:
-
Are ladders in good condition, without damages?<br>
-
Are ladders being inspected before each use?<br>
-
Are ladders being inspected monthly? (Monthly inspection stickers are in place and updated.)<br>
-
Are labeling/marking on ladders legible?<br>
-
Do all ladders have the capacity rating posted?<br>
-
Do all portable ladders have safety feet?<br>
Stairs and Walkways
Stairs and Walkways
-
Stairs and Walkways Audit Questions:
-
All stairs and walkways in good working conditions?<br>
-
Are proper height on all handrails, at least 42 inches?<br>
-
Are swing gates installed on all working platforms?
-
Are there toe boards on all walkways?
-
Are housekeeping practices carried out to ensure work areas are safe from trip/fall hazards to employees?
LSR 10. Safety of Materials Under Pressure
LSR 10. Conveyance and Storage of Materials Under Pressure
-
Conveyance and Storage of Materials Under Pressure Audit Questions:
-
Are all compressed gas cylinders secured in a safe manner and properly capped when not in use?
-
Are oxygen cylinders stored away from flammable materials and at least 25 feet from flammable gas cylinders?
-
Are required inspections performed on all pressure vessels/compressors?
-
Are storage areas for cylinder bottles labeled, "Full" or "Empty"?
-
Does all high pressure lines have the approved high pressure clamp? No radiator clamps?
-
Is compressed air used for cleaning purposes regulated to 30 pounds?
LSR 7. Lifting Operations
LSR 7. Lifting Operations
-
Lifting Operations Audit Questions:
-
Do all lifting implements such as straps, cables and chains have their load limit identified, as applicable?
-
Are all safety latches in place?
-
Are lifting hoists inspected prior to each use with proper load limits posted?
-
Are employees only lifting objects less than 50 pounds on their own?
LSR 4. Machinery Guarding
LSR 4. Machine Guarding
-
Machine Guarding Audit Questions:
-
Are all points-of-operations and pinch points guarded?
-
Is there barrier guards on moving machinery parts?
-
Are all floor holes, floor openings, hatchways, manholes, wall openings and skylights properly guarded?
-
Are belts/pulleys enclosed?
-
Are light bulbs guarded?
-
Are all guards in place on power tools?
-
Is the bench grinder in a safe condition? (Placed at least 1/4 inch from wheel and guard in place)
Hot Work
Hot Work
-
Hot Work Audit Questions:
-
Are welding operations screened to prevent flash injuries?
-
Are extra fire extinguishers present for welding operations?
LSR 2. Equipment Safety
undefined
Pedestrian/Vehicle Segregation
-
Pedestrian/ Vehicle Segregation Audit Questions:
-
Are traffic flow signs posted, positioned appropriately and visible?
-
Are the appropriate signs in place around site? (Phone Use, Do Not Enter, Speed Limit, Pedestrian Crossing, etc.)
-
Is there a Pedestrian Segregation written plan in place?
Mobile Equipment
-
Mobile Equipment Audit Questions:
-
Are daily pre-use equipment inspections being done?
-
Is there a 3-Point of Contact decal in place on steps of all equipment?
-
Are chalks made available and used when required?
-
Do employees understand and comply with the mobile phone policy?
LSR 5. Confined Space Entry
LSR 5. Confined Space Entry
-
Confined Space Audit Questions?
-
Is the Confined Space Manuel in place and being used properly?
-
Is the Confined Space Monitor being calibrated and logged before use?
-
Are bump tests being performed before each entry and logged?
-
Are all confined space areas properly labeled?
Housekeeping
Housekeeping
-
Housekeeping Audit Questions:
-
Is the site practicing good housekeeping in all buildings?
-
Are microwaves and refrigerators maintained in a sanitary and safe operational condition?
-
Is the site practicing good housekeeping of restrooms?
-
Is the site practicing good housekeeping throughout the site?
-
Are outside storage areas in good condition?
-
Are garbage containers provided and used?
-
Is the entrance to the yard and office clean and tidy?
-
Are all containers labeled and labeled correctly?
-
Are eyewash stations easily accessible and maintained?
Parts Washer
-
Parts Washer Audit Questions:
-
Do parts washer have retractable lid mechanisms or fusible link?
-
Are face shield, gloves and apron available and used when operating parts washer?
-
Are there adequate ventilation?
Environmental Housekeeping
Housekeeping
-
Housekeeping Audit Questions:
-
Are all containers used to catch oil covered and or not exposed to the weather?
-
Are containment in good condition with no leaks and cracks?
-
Are there stains on the ground around the site that need to be cleaned up?
-
Are areas where water runoff leaves the site free of visible silt?
-
Are dumpsters being kept closed?
-
Is wind blown trash being removed and placed in trash containers?
-
Is there evidence of offsite tracking of materials or sediment?
-
Are Used Oil Tanks properly labeled as "Used Oil"?
-
Are all on-site containers, containing fluids, labeled as to their content?
-
Do all on-site containers have SDSs available for the contents?
-
*Does facility have proper structural controls? (berms, ponds)
-
Is structural controls effective and maintained?
-
Major concerns
concern
-
Photos to aid with description:
-
Description:
Documentation
Documentation On File
-
Documentation Audit Questions:
-
Where are Weekly Safety Talks including roster and materials kept?
-
Is there proof of all employees operating machinery being trained on-site or at the local safety office?
-
Is there proof of all drivers being trained in the company safe driving programs (DDC or Smith System)?
-
Is there documentation of all required employees completing LOTO training on-site or at local safety office?
-
Is there documentation for all required employees who perform confined space entrance on-site or at local safety office?
-
Is there proof of all employees completing fall protection training on-site or at local safety office?
-
Is there documentation that employees have received rigging and lifting training on site or at local safety office?
-
Is there documentation that employees have received pressurized system training on site or local safety office?
-
Is there proof of employee engagement in Near Miss/Potential Hazard reporting, behavior observations, and/or mentoring program on site or at local safety office?
Unsafe Conditions
-
Other unsafe behaviors or conditions observed on site:
Observed
-
Description of observation:
-
Pictures to aid in observation:
Signatures
-
Check the box to approve that the above audit was done by a Safety Representative?
-
Safety Representative Signature:
-
Title:
-
Have the Site Manager or Site Representative check the box, agreeing that they received a briefing after the completion of the audit.
-
Site Manager/ Site Representative Signature:
-
Title: