Audit Title
-
Client / Site
-
Location
-
Prepared by
-
Contact phone number
-
Conducted on
-
Other staff
-
Development Application Number
-
Complying Development Number
-
Construction Certificate Number
Inspection items
-
Appropriate steel has been selected and utilised
-
Notes
-
Steel members are not defective
-
Notes
-
Layout of structure is as per the development consent
-
Notes
-
Timber size is appropriate and grading is appropriate for the construction
-
Notes
-
Flashing is appropriately installed
-
Notes
-
Damp course is appropriately installed
-
Notes
-
Roofing material as per development consent
-
Notes
-
External cladding as per development consent
-
Notes
-
Penetrations, cuttings or notches do not exceed product specifications
-
Notes
-
All fire resistant material is installed appropriately in fire rated elements
-
Notes
-
Non-combustible materials have been installed as required
-
Notes
-
Unlike metals within the frame are spaced or adequately protected from galvanic corrosion
-
Notes
-
No visible corrosion detected
-
Notes
-
Hoop iron straps have been installed in single leaf masonry garage and double brick constructed dwellings
-
Notes
-
Bracing as per fabricators or engineers specifications
-
Notes
-
Steel frame installed as per manufacturers specifications
-
Notes
-
Fixings as per fabricators or engineers details
-
Notes
-
Masonry has full mortar joints
-
Notes
-
Masonry has expansion joints if required
-
Notes
-
Insulation has been installed in accordance with BASIX
-
Notes
-
Development as per the Development Consent
-
Noted unauthorised development
-
Site notes
-
Photograph
Required information
-
Required information to be submitted to Council
- Engineers certificate certifying the timber frame outside the scope of the engineers details
- Engineers certificate for masonry outside the scope of AS 3700
- Installation certificate of all fire rated construction elements
- Steel frame details from manufacturer
- Identification survey indicating the overall height of the structure
Inspection result
-
Result of the inspection
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory - reinspection required after rectification works carried out
- Unsatisfactory - works not complete
- Stop all works - contact councils duty planner on 9735 1222, regarding unauthorised works
-
Should you have any enquiries regarding this inspection report please contact Auburn City Council on 9735 1222 or via email council@auburn.nsw.gov.au or in person at the customer service centre located at 1Susan Street, Auburn.