  • Site Code

  • Site Name

  • General Comments:

  • Inspection completed on

  • Prepared by

  • Location
  • Work completed by:

General

  • All/any damage done during construction repaired( Environment and general)

  • Site locked on arrival

  • Site/Shelter/Cabinets neat, clean and tidy, cabinets closed? All waste materials removed? Spare material and parts neatly and securely stored or returned?

Civil Construction

  • Foundation as per design, clean and no visible cracks etc.

  • Fence as per design, sturdy, and no visible damage.

  • Earthing as per design and inspection hole cables secure?

  • Confirm Timber Specs as per Design.

  • Mains cable marked at point of entry to compound area

  • The label of earth Resistance recorded and COC in cabinet door

  • Cabinets installed on Damp Course and secured

  • Latchway Certified

Cabinet assurance check

  • Cabinet & equipment have been positioned and accounted for as per design layout.<br>

  • Upon completion of the installation, the cabinets should stand stable. The cabinet must be level. Equipment doors locks and covers functions correctly. Antistatic wrist strap must be connected to ESD jack.

  • Cable entries into cabinet managed and entering through correct access plates/holes.

  • Cabinet is earthed, earth correctly labelled and no copper exposed?

  • Cable management appropriate and labelled?

  • RF connectors torqued between 25n.m & 30n.m?

  • Ensure all Cards are secure in rack

  • WISP and RCG Separation shelf installed

TI Installation

  • Alarm and RS485 cable installed on Tx cabinet FPFH and labeled as per standard

  • IDU installed in correct position.

  • Dish and ODU out of way from climbing ring

  • Spare ports antenna weatherproofed with approved caps

  • GPS antenna installed on top of pole.

  • All batteries connectors terminals greased, secured, etc.

  • All ducts sealed against vermin.

  • All cables, etc labeled and neatly routed as per standard.

DC Distribution

  • DC cables managed, labelled and no copper showing?

Feeders/ Hybrid Cables

  • Correct feeder type has been installed as per design?<br>

  • Feeders/ hybrid cable managed appropriately?

  • Feeder/Hybrid cable entries sealed?

  • Feeder/Hybrid/jumper cables not exceeding bending radius & in accordance with manufacturers specifications?

Earth/ Grounding

  • Earth connections not doubled up?

  • Earths appropriately managed including bending radius?

  • Contact paste applied to required earth connections.

Antennas, RRU's

  • Antennas correct type ?

  • Antennas and mounts installed in correct locations as per design?

  • RRU and mounts installed in correct locations?

  • RRU's earthed?

  • Orientations (Azimuth) checked as per RF Design (visual check with handheld compass only)?

General questions

  • Signage installed as per requirement

  • Photo's of signage.

  • Photo of power meter ( clearly displaying ICP number)

Photo's

Photo's

  • Site access photo.

  • Internal shelter photo showing cabinet location.

  • Cabinet layout view ( shows detailed overview of BTS).

  • Photo displaying overall cable management.

  • Photo of Cable entry

  • Close up BBU

  • Photo from each antenna face.

  • Additional photos!

  • Auditor signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.