Information
-
Field Supervisor
-
Operator #1
-
Operator #2
-
On Call Manager
-
Conducted On
-
Oil Company
-
UWI
TCP Firing Head
-
Correct firing head used for TCP application (i.e. Pressure Activated, Auto-Vent, Percussion, etc...)
-
TCP firing head calculator used to determine correct number of pins to use on a pressure activated TCP based on well bore conditions? (i.e. Fluid type, fluid level, depth at top shot, etc.)
-
Firing head pressure is above 1000psi safety factor and meets clients request for activation pressure at surface and at firing head?
-
Was a complete rebuild of the firing head completed? (This includes o-rings, firing pin (if applicable), Teflon seals (if applicable))
Tubing Drain
-
Was a complete rebuild of the tubing drain completed? (This includes o-rings, Teflon seals (if applicable))
-
Correct size of tubing drain selected for casing size it's being ran in?
-
Correct number of pins used in tubing drain based on well bore conditions? (i.e. Fluid Type, fluid level, depth. etc.)
-
Correct pins used from proper manufacturer to match the tubing drain being ran?
TCP Equipment and Jewelry
-
Correct length and style of drop bar selected based on clients request? (if Applicable)
-
Correct jewelry selected for TCP type and application? (i.e. Fill Flow Sub, Separation Sub, Ported Differential, Non-Ported Differential, Kobes Sub)
-
Is a tubing swivel required for the TCP application?
-
If so, if the tubing swivel the proper one being used for the size and drift of casing that it is being ran in?
-
Have all equipment bring ran in the well bore been calipered to ensure it is the correct size for the casing in which it is being ran? (Note: Must ensure all equipment is slightly below drift of the casing, not the ID of the casing)
Perforating Guns
-
Is the correct c-plate used for TCP application?
-
Is a DOG COLLAR required for the job?
-
If so, is the correct size being used for the size of guns being used on the TCP?
-
Are orientation fins required for this TCP application?
-
If so, is there a fin welded to the top section on 1/3 of the guns being deployed in the well bore?
-
Are the fins welded in a manner to allow proper orientation? (1.e. 90/270, 150/210, etc.)
-
Is a debris magnet required on this TCP job?
-
If so, is the correct bottom sub selected that will allow the magnet to be connected to the bottom most gun?
Additional Comments / Concerns Regarding TCP Job?
Final Check
-
Have all equipment and checklist been reviewed between the Field Supervisor and the on call Manager?
-
Select date