Title Page
-
Conducted on
-
Prepared by
-
Park
-
Residence Name
Grounds
-
Proper grading drainage away from structure.
-
No evidence of standing water
-
Downspout drainage directed away from structure
-
No leaks from septic tank or leech field
-
Yard, landscaping, trees and walkways in good condition
-
No branches or bushes touching structures
-
Exterior additional structures (fences, sheds, decks, garages ect.) in good condition, no evidence of termite or rotted wood
-
Driveways, sidewalks, patios,entrance landings in good condition.
-
Railings on stairs and decks are adequate and secure
-
Overhead electrical lines are free of trees & bushes
-
Exterior electrical panels have proper access, properly labeled & no missing breakers.
-
Exterior receptacles are GFCI protected. GFCI is tested and working properly.
-
Exterior receptacles have proper covers and are protected from weather.
-
Exterior faucets are equipped with backflow prevention devices
Structure
-
Ridge & fascia board lines appear straight and level
-
Sides of house appear straight, not bowed or sagging
-
Window and door-frames appear square (especially bowed windows)
-
Visible foundation is in good condition - appears straight, plumb, with no significant cracks
Exterior Surfaces
-
Adequate clearance between ground and wood siding materials (6" minimal), no wood to earth contact
-
Siding: no cracking, curling. loose, rot or decay
-
Masonry veneers: no cracks in joints, no broken, spalling or flaking components
-
Vinyl or aluminum siding: no dents, damage, no bowing or loose siding
-
No vines on surface of structure
-
Exterior paint or stain, no flaking or blisters
-
No abnormal stains on exterior surfaces
Windows, Doors & Wood Trim
-
Wood frames and trim pieces are secure, no cracks, tor or decay
-
Joints around frames are caulked
-
No broken glass (window or storm panes) or damaged screens, no broken double panes, insulated window seals.
-
Storm Windows or thermal glass used?
Roof
-
Composition shingles: no curling, no cupping, no loss of granulation particulate, no broken, damaged or missing shingles, no more than two layers of roofing.
-
Wood shingles or shakes: no mold, rot or decay, no cracked/broken/missing shingles, no curling.
-
Flat roofs: no obvious patches, no cracks or splits, minimal blisters/"alligatoring" and wrinkles, no silt deposits (indicates improper drainage), sealed tar at flashings.
-
Flashing around roof penetrations.
-
No evidence of excess roofing cement/tar/caulk.
-
Soffits and fascia: no decay, no stains.
-
Exterior venting for eave areas: vents are clean and not painted over.
-
Gutters: no decay or rust, joints sealed, attached securely to structure, no bending or sagging, no section of gutter or downspout missing, gutters clean, no mud deposits.
-
Chimneys: straight, properly flashed, no evidence of damaged bricks or cracked joints, mortar/cement cap in good condition.
Attic
-
No stains on underside of roofing, especially around roof penetrations.
-
No evidence of decay or damage to structure.
-
Sufficient insulation and properly installed insulation (faced insulation moisture barrier is installed closest to the heated area of the house).
-
Adequate ventilation, clear path into attic for air entering through soffit vents, adequately sized gable end louvers, all mechanical ventilation operational.
-
No plumbing , exhaust or appliance vents terminating in attic
-
No open electrical splices
-
Stair access to attic is in working order with no missing or loose pieces.
Interior Rooms and Hallways
-
Floors, walls and ceilings appear straight and plumb and level.
-
No stains on Floors, walls or ceilings.
-
Flooring materials in good condition.
-
No significant cracks in walls or ceilings.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay; windows and doors have weather-stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check).
Bedroom #1
-
Floors, walls and ceilings appear straight and plumb and level.
-
No stains on floors, walls or ceilings.
-
No significant cracks in walls or ceilings.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay; windows and doors have weather-stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check).
Bedroom #2
-
Floors, walls and ceilings appear straight and plumb and level.
-
No stains on floors, walls or ceilings.
-
No significant cracks in walls or ceilings.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay; windows and doors have weather-stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check).
Bedroom #3
-
Floors, walls and ceilings appear straight and plumb and level.
-
No stains on floors, walls or ceilings.
-
No significant cracks in walls or ceilings.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay; windows and doors have weather-stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check).
Kitchen
-
Working exhaust fan that is vented to the exterior of the building.
-
Plumbing fixtures function correctly.
-
Exhaust filters are clean with no accumulation of lint and grease.
-
Ground Fault Circuit Interrupter ("GFCI") protection for electrical outlets within 6 feet of the sink(s).
-
Dishwasher: drains properly, no leaks, baskets, door spring operates properly.
-
No leaks in pipes under sinks.
-
Floor in cabinet under sink solid, no stains or decay.
-
Water flow in sink adequate.
-
No excessive rust or deterioration on garbage disposal or waste pipes.
-
Built-in appliances operate properly.
-
Cabinets in good condition: doors and drawers and hardware operate properly.
-
List All State Owned Appliances:
Bathroom #1
-
Working exhaust fan that doesn't terminate in the attic space.
-
Plumbing fixtures function correctly.
-
Adequate flow and pressure at all fixtures.
-
Sink, tub and shower drain properly.
-
Plumbing and cabinet floor under sink in good condition.
-
If sink is metal,it shows no signs of rust, overflow drain doesn't leak.
-
Toilet operates properly.
-
Toilet stable, no rocking, no stains around base.
-
Caulking in good condition inside and outside of the tub and shower area.
-
Tub or shower tiles secure, wall surface solid.
-
No stains or evidence of past leaking around base of bath or shower.
-
GFCI protection for electrical outlets within 6 feet of a water.
Bathroom #2
-
Working exhaust fan that doesn't terminate in the attic space.
-
Plumbing fixtures function correctly.
-
Adequate flow and pressure at all fixtures.
-
Sink, tub and shower drain properly.
-
Plumbing and cabinet floor under sink in good condition.
-
If sink is metal,it shows no signs of rust, overflow drain doesn't leak.
-
Toilet operates properly.
-
Toilet stable, no rocking, no stains around base.
-
Caulking in good condition inside and outside of the tub and shower area.
-
Tub or shower tiles secure, wall surface solid.
-
No stains or evidence of past leaking around base of bath or shower.
-
GFCI protection for electrical outlets within 6 feet of a water.
Miscellaneous
-
Smoke and carbon monoxide detectors where required by local ordinances- inside and immediately outside each bedroom.
-
Fire Extinguishers are available and have been inspected annually, as required.
-
Stair handrails are placed where needed and are in good condition.
-
Automatic garage door opener operates properly, stops properly for obstacles.
-
Clothes dryers are properly vented to the exterior with rodent resistant vent flap and ducts are free of accumulated lint.
Mechanical Room
-
No evidence of moisture.
-
Exposed foundation; no stains, no major cracks, no flaking, no efflorescence.
-
Visible structural wood; no sagging, no damage no decay, no stains, no damage from insects, sills attached to foundation with anchor bolts.
-
HVAC operates on heat and cool settings.
-
HVAC filter is in place and is clean
-
Breakers are labeled as to what they control and breaker boxes have no open slots or missing breakers.
Crawl Space
-
Adequately vented to exterior.
-
Insulation on exposed water supply, waste and vent pipes.
-
Insulation between crawl space and heated areas, installed with vapor barrier towards heated area.
-
No evidence of insect damage.
-
Underpinning in good shape.
Plumbing
-
Visible pipes: no damage, no evidence of leaks, no signs of stains on materials near pipes; drain pipes slope slightly down towards outlet to septic/sewage system.
-
Water heater: no signs of rust, vented properly, equipped with T&P valve, sized to produce adequate quantities of hot water for the number of bedrooms in the house.