Title Page
-
Blyth Offshore Demonstrator
-
Conducted on
-
Mark Hardy
-
Location
Untitled Page
01. Foundation
-
Check for damages TP / Foundation
-
Inspect latch way and yoyo.
-
Check platform graiting/floor outside
-
Check cabling and pipe exits
-
Visually check the cooler units.
-
Check external light.
-
Check anchor points..
-
Check entrance stairs
-
Check tower entrance, warning stickers and door
02. Tower Base - Description of inspection area/component
-
Visually check inside ground controllers for dirt/dust, door latches and hinges
-
Check function of dehumidifier
-
Visually inspect fire extinguisher and first aid kit.
-
Check cables for damage, zip ties and proper routing into controllers and cabinets.
-
Visually inspect service lift
-
Check generator if present.
-
Grounding on base tower/TP
-
Flange bolts torque marked and torque date written, washers/nuts mounted correct.
-
Check routing of HV cable in tower base
-
Check tower for paint damage inside
-
Check wires on service lift in tower base.
-
Visually inspect Avanti rail system
-
Check general cable work
-
Visually check for overall cleanliness
-
03. Yaw - Description of inspection area/component
-
Visually check for cleanliness in and around yaw.
-
Check cable work, communication and earthling cables, wear and tear.
-
Check power cables wear and tear.
-
Check oil level on yaw gears.
-
Visually check yaw gears for damage
-
Check auto lubrication for yaw
-
Check that the yaw top is lubricated on slide surface and on teeth
-
Listen for abnormal noise when the nacelle yaw CW and CCW
-
Inspect cable work and routing.
-
Check ladder is free of damages and for lose bolts.
-
Check platform attachment and signs of vibration
-
Other issues yaw
04. Nacelle - Description of inspection area/component
-
Check rotor lock hydraulics for oil level and operation.
-
Check controller cabinets and cabling left side nacelle.
-
Check cooling water level.
-
Check cooling water pumps and hoses for leaks, left side nacelle.
-
MSI cabinet for cables and cooling hoses for damage/leaks etc. Back end nacelle.
-
Check lubrication oil tank, oil level.
-
Check leaks around lubrication oil tank.
-
Check leaks around lubrication oil tank.
-
Visually check for leaks around hydraulic station.
-
Check for correct Hydraulic oil level, hydraulic station.
-
Check controller cabinet and cabeling right side nacelle.
-
Check gear box for correct oil level.
-
Check hoses and pipes for leaks, right side drive train.
-
Operation and condition of main hatches and hatch seals hydraulic rams, hoses etc
-
Other issues right side drive train.
-
Check wire, cable work and hoses on crane
-
Check for leaks, back end of the generator
-
Check cable work back end of the generator.
-
Check slip ring/ rotating union, hoses and cable work..
-
MSI cabinet for cables and cooling hoses for damage/leaks etc.
-
Check that the internal crane and hook is proper secured.
-
Other issues back end drivetrain.
-
Check hoses and pipes for leaks, left side drivetrain
-
Visually inspect first aid kit.
-
Visually inspect fire extinguisher
-
Visually inspect rescue kit if present.
-
Other issues left side drive train.
-
Operation and condition of all access hatches and hatch seals.
-
Visually check for nacelle top-level cleanliness.
-
Check lubrication oil pumps for operation. ( Gear, Main bearing and Generator)
-
Check cooling water pumps for operation
-
Check hydraulic pumps for operation.
-
If present, turn "off- line" filter motor on and check that it is operating
-
Check operation of cooling / heating fans.
-
With the controller set to auto yaw, bring the generator to 1000rpm and listen for abnormal noise from bearings and gearbox transmission.
-
With the controller set to auto yaw, bring the generator to 1000rpm and listen for abnormal noise from bearings/generator.
05. Nacelle Basement - Description of inspection area/component
-
Check for main bearing for leaks.
-
Inspect yaw / yaw claws.
-
Check cable work right side nacelle basement under controller cabinet
-
Check cable work back end nacelle basement
-
Check for leaks under generator..
-
Check for leaks under gear box..
-
MSI cabinet for cables and cooling hoses for damage/leaks etc
-
Check hose and pipe connections in nacelle basement.
-
Check magnets and swarf sensors in gearbox for debris
-
Check cable work left side nacelle basemen
-
Inspect hoses for wear and tear.
-
Other issues in nacelle basement.
06. Hub - Description of inspection area/component
-
Check Lightning Current Transfer Unit (LCTU)
-
Check for damage on nose cone support. Spinner area.
-
Check blade collars for damage
-
Check anchor points.
-
Check entrance hatches and handles, hinges and hinge retaining clips are present
-
Spinner Escape hatches are secured and operational.
-
Visually inspect hub controller and confirm that modules and connectors are security tightened.
-
Check cable work in hub for prober routing and wear.
-
Check function of light in hub
-
Check for hydraulic leaks
-
Check that accumulators are properly secured including protection caps.
-
Check accumulator pressure in Hub.
-
Check pitch cylinders for leaks and that they are securely tightened
-
Check inside the blades the lightning card/conductor. and cable work.
-
Check blade bearing seals for leaks
-
Blade bearing bolts for rust and torque marks etc.
-
Check hydraulic hoses in hub for proper routing and wear
-
Check auto lubrication for blade bearings
-
Visual check the hub for overall cleanliness
-
Other issues hub
07. Nacelle external - Description of inspection area/component
-
Check cooler for damages and rust
-
Check hoses and pipe connections on cooler
-
Check Anchor points.
-
Check fiber glass for cracks.
-
Visual check nacelle hatches and hub/blades from platform.
-
Check operation of Wind sensors and anometer.
-
Other issues Nacelle external.
08. Top Tower - Description of inspection area/component
-
Check tower damper visually at both platforms, turnbuckles are tight.
-
Spot Check Visually if there are any loose bolts on ladders and landings
-
Ladder is free of damage.
-
Cable work up tower is neat, secured, and is free of damage.
-
Visually check platforms all levels, attachment/turnbuckles and signs of vibration
-
Check anchor points.
-
Check service lift wire attachment.
-
No damage to Lift access gates and is fully operational
-
Cable work, snowflakes not slipped down and in center of barrel.
-
Check cable loop.
-
Check grounding between platforms and tower.
-
Tower sections are grounded together, bolts are torque marked.
-
Flange bolts torque marked and torque date written, washers installed correctly.
-
Corrosion protection bolts
-
Cable routing power cables.
-
Check cable work at flange level.
-
Visual check for overall cleanliness
-
Other issues tower
09. Middle Tower - Description of inspection area/component
-
Spot Check Visually if there are any loose bolts on ladders and landings
-
Ladder is free of damage.
-
Cable work up tower is neat, secured, and is free of damage.
-
Visually check platform, attachment/turnbuckles and signs of vibrations.
-
Check anchor points.
-
Check grounding between platform and tower.
-
Tower sections are grounded together, bolts are torque marked.
-
Flange bolts torque marked and torque date written, washers installed correctly.
-
Corrosion protection of bolts.
-
Cable routing power cables.
-
Check cable work at flange level..
-
Visual check for overall cleanliness
-
Other issues tower
10. PCM 4 Level. - Description of inspection area/component
-
Visually, check sealing survival kit.
-
Visually, check crane and for operation.
-
Visually, check conditioning unit.
-
Check grounding on PCM level 4.
-
Other issues PCM 4 level.
undefined
11. PCM 3 Level. - Description of inspection area/component
-
Check cabinets, if possible inside as well
-
Check cable work.
-
Check cooling pipes water and air. if present.
-
Check grounding on PCM level 3 and between platform and tower.
-
Other issues PCM 3 level.
12. PCM 2 Level. - Description of inspection area/component
-
Check cabinets, LSI for leaks corrosion on busbars etc.
-
Check cable work.
-
Check cooling water pump and hose/pipe connections for leaks
-
Check grounding on PCM level 2 and between platform and tower.
-
Other issues PCM 2 level.
undefined
13. PCM 1 Level. - Description of inspection area/component
-
Check cable work.
-
Check grounding on PCM 1 level and between platform and tower.
-
Other issues PCM 1 level.
undefined
14. Bottom Tower- Description of inspection area/component
-
Spot check visually if there are nny loose bolts on ladders and landings.
-
Ladder is free of damages.
-
Cable work up tower is neat, and is free of damages.
-
Visually inspect Avanti, or other, rail system
-
No damage to Lift access gate and is fully operational at all PCM levels.
-
Check anchor points.
-
Other issues bottom tower.