Title Page
-
Site conducted
-
CONDUCTED ON
-
PREPARED BY
-
CLIENT
- DOWNER
- SOUTHERN DOWNS
- UNITY WATER
- MACKAY REGIONAL COUNCIL
- SUNSHINE COAST REGIONAL COUNCIL
- THE WATER CORPORATION
- OTHER
-
IDENTIFY CLIENT
-
PROJECT CODE
-
IDENTIFY PROJECT CODE
MH DETAILS
-
MH ASSET #
-
ADDRESS
-
MH LID TYPE
-
IS THE MH LID BOLTED DOWN?
-
IS THERE A GAP BETWEEN THE LID RIM AND THE START OF THE WALL
-
WHAT IS THE MEAUREMENT?
-
MH DIAMETER
-
MH DEPTH
-
LOCATION OF MH
- ON ROADWAY
- ON FOOTPATH/ROAD RESERVE
- ON PRIVATE PROPERTY
- ON PRIVATE DRIVEWAY - UNPAVED
- ON DRAINAGE EASEMENT
- ON PARKLAND/CREEK
-
IS MH ABOVE OR BELOW SURFACE LEVEL?
- Above
- Below
-
HEIGHT OF MH FROM SURFACE LEVEL?
-
IS MH ACCESS HINDERED AND HOW?
- No
- Inside building
- Buried
- Locked yard / dog or pet
- Under debris /rubbish
-
DOES THE MH COVER PRESENT AS A TRIP HAZARD?
MH CONDITION
-
MH LID FRAME CONDITION?
- Good
- Offset
- Loose
- Cracked
- Corroded
-
MH LID NECK CONDITION?
- Good
- Corroded
- Cracked
- Incorrectly fabricated with diameter reduction
-
MH WALL MATERIAL?
- Concrete
- Brick
- Mixed
-
MH WALL CONDITION?
- Good
- Lined
- Satisfactory
- Poor
- Bad Suphide Attack
- Cracking
- Leaking
-
MH WALL ADDITIONAL DETAIL (if leaking, cracking or sulphide attack)
-
MH CONFIGURATION?
- Conical
- Segmented
- Pre-cast
-
NUMBER OF STEP IRONS, SPACING AND MATERIAL?
-
NUMBER OF LADDERS, LENGTH AND MATERIAL?
-
STEP IRONS / LADDER CONDITION?
- Ladder
- Step Irons
- Good / Satisfactory
- Replace partial length
- Missing
- Full Replacement requried
- N/A
-
MH BENCHING CONDITION
- Good
- Needs Repair
- Missing
- Poor shape (inhibits smooth flow)
-
INCOMING LINES ?
- Yes
- No
-
HOW MANY?
-
INCOMING LINE DETAILS - MATERIAL, SIZE (mm), LOCATION, HEIGHT
-
INCOMING LINE HAS EXTERNAL DROPPER?
-
IS THE EXTERNAL DROPPER AGAINST THE WALL?
-
ANY INFILTRATION?
- Yes
- No
-
IDENTIFY TYPE OF INFILTRATION
- SWEATING
- DRIPPING
- RUNNING
- GUSHING
-
IDENTIFY THE EXTENT OF INFILTRATION
- Localised
- Medium
- Severe
-
IS CORROSION IDENTIFIED WITHIN THE MH?
- Yes
- No
-
IDENTIFY APPROXIMATE DEPTH OF CORROSION (mm)
-
BACKDROPS IN MH
- Yes
- No
- Good Condition
- Blocked and needs cleaning
- Needs Repair
-
IS THE MH AFFECTED BY TREE ROOTS?
- Yes
- No
- Underneath top slab
- Through benching
- From sewer pipe
- Through MH wall
-
IS STORMWATER LIKELY TO POND AROUND MH?
- Yes
- No
-
ADDITIONAL PHOTOS - IF REQUIRED
-
GENERAL COMMENTS
REHABILITATION RECOMMENDATIONS
-
REHABILITATION SCOPE
- MHLocate and raise
- Replace Mh lid / frame
- Replace MH step irons
- Install and or replace MH ladder
- Repair MH benching
- Unblock drop pipes / backdrops
- Replace broken / missing/ damaged drop pipe
- Seal under MH aspro
- Consider lining the MH due to sulphide attack
- Seal MH lid to reduce inflow
- Remove illegal connection into MH
- No Action required