Title Page
-
Site photo
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
Site manager
External
-
External caulking Window
-
External caulking Door
-
AJ caulking
-
Decking
-
Brick fence
-
Downpipe connection
-
Water tank connection
-
Pit cleaning, pit cut back and rendering
-
Water flow away from property
-
All external step raiser consistent and no more than 190mm
-
All external step going is consistent and more than 240mm
-
Boundary wall as per plan (no higher than 3.2m or average no more than 3.6m)
-
Any gap around window
-
Any gap around door
-
Boundary fence no overlooking issue
-
All fire rate wall done as per plan (decking, party wall and eave)
-
Fire rate insulation as per drawing requirement
-
AJ are done as per plan
-
Weephole clean
-
Weephole has minimum 50mm above Naturel Ground Level
-
Porch and backyard finish level more than 50mm below house level
-
Flashing and capping completed and water flow away from property
Internal
General
-
Entry door frame side seal
-
Entry door bottom seal
-
Window glazing as per drawing (double glaze and single glaze)
-
First floor window opening no more than 125mm
-
Garage to house door frame side seal
-
Garage to house door bottom seal
-
Smoke alarm as per plan (less than 1000mm from staircase or bedroom)
-
House finish level higher than the house min 50mm
Balcony
-
Balustrade more than 1000mm
-
Caulking
-
Floor over flow
-
minimum 50mm drop from house to balcony
Laundry
-
External door side seal
-
External door bottom seal
-
Laundry tub connection
-
mixer connected
-
Splashback
-
Caulking
Staircase
-
Step raiser consistent and no more than 190mm
-
Step going is consistent and more than 240mm
-
No more than 17 step or have a landing if more than 17 steps
-
Handrail run continuously
-
First floor Balustrade more than 1000mm high (after carpet)
-
Between Balustrade vertical bar no more than 125mm gap
-
Staircase head high more than 2000mm
Ground Floor Bathroom
-
Shower screen installed with solid support
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan
Ground Floor Powder room
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan
-
If under staircase any head high issue (ceiling high 2100mm)
First Floor Powder room
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan
First floor Bathroom ENS 1
-
Shower screen installed with solid support
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan
First floor Bathroom 1
-
Shower screen installed with solid support
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan
First Floor Bathroom 2
-
Shower screen installed with solid support
-
mixer connected
-
Splashback
-
Caulking
-
Basin connection
-
Fan