Information
-
Company
-
Select date
-
Lease
-
Rig #
-
Operation
-
Operator
-
Company rep.
-
Rig Manager
-
Driller
-
Days since last recordable accident
-
Days since last lost time accident
Location Safety & Safety Equipment
-
Signs in place at location entrance. Std. 1910.145
-
No smoking. Std. 1910.145
-
Hard hat area. Std. 1910.145
-
Steel toe boots. Std. 1910.145
-
Eye protection required w/ side shields. Std. 1910.145
-
Authorized personnel only. Std. 1910.145
-
Cell phone use in designated area only. Std. 1910.145
-
Visitor tracking system in place. Std. 1910.38
-
Clearance from all energized power lines 10 ft. Std. RP54 10.1.1
-
Emergency escape device in place & installed properly. Std. 1910.36
-
Geronimo on-line and ready for immediate access and use. Std. RP54 6.10.1
-
All guy wires flagged & up. Std. RP4G 7.6.F
-
Fire extinguishers at each anchor min (2-30#) Std.1910.157
-
No vehicles inside of anchor pattern when possible. Std. RP545.1.15
-
First aid kit in place, full, clean, and good condition. Std. 1910.151
-
Blood borne pathogen kit. Std. 1910.151 (b)
-
Eye wash station in place. Std. 1910.151
-
Hearing protection provided. Std. 1910.95
-
Fall protection to assure 100% tie off 100% of the time. Std. 1910.66
-
Full body harness w/double climbing hook or y-lanyard. Std. 1910.66
-
Self retracting life line attachment in good condition. Std. 1910.66
-
Self retracting line used at tubing board. Std 1910.132
-
Double latch hooks on all lanyards & lifting rigging. Std 1910.66
-
Breathing packs in place @ anchors. Std. RP55 3.3
-
H2S sensors in place and calibrated, checked daily. Std. 1910.1000.E
-
Wind sock or flag in place. Std. RP55 4.5
-
Designated smoking area posted. Std. 1910.145.C.2.i
-
Safe briefing areas designated and posted. Std. 1910.38.C.4
-
Emergency phone list. Std. RP54 4.2.1
-
OSHA poster. Std. 1903.2 (A)(II)
-
Additional Comments
Guy Lines
-
Minimum 4 crown guys anchored. Std. RP4G 6. 1-8
-
Tubing board guys crossed and anchored properly. Std. RP4G7. 1-8
-
Mast guy lines proper size - 5/8" min- with factory eyes @ crown (swedged & thimbled & tagged) Std. RP9B3.7.4
-
Approved clevis's attaching guy line to Derrick. Std. BP H/L TBL 5
-
Tubing board guy lines proper size - 9/16" min. - with factory eye's at board and crossed with appropriate sag (10/12). Std. RP9B3.7.4 BP H/L TBL 5
-
All guy lines in good condition- free of kinks, wickers, & corrosion. Std. RP4G 5.1.C
-
Ground anchors with weatherproof tag permanently attached to each anchor installed & pull tested every 2 years w/ documentation. Std. RP4G 14.5
-
All anchors inspected w/ tag and visible markers. Std. RP4G14.5
-
All chains secured. Std. RP4G 7.1-8
-
All non-factory ends fitted with min. 3 clamps of proper size or 4 clamps if through sheaves. Std. RP4G13.3 & RP9B 3.7.4
-
Additional Comments
Foundation
-
Check location for solid footing under unit. Std. RP4G15.1
-
Steel mat under load bearing portion of rig and jacks where foundation is questionable. Std. RP4G15.1
-
Additional Comments
Mast / Derrick
-
Manufacturer name and specs. Plate in place and legible. Std. RP4G52.1
-
Guying data plate on Derrick. Std. RP54-9.9.2
-
Derrick/mast certification 5yr. Std. RP54/RP4G
-
Derrick/mast load path certification 2 yr. Std. RP54/RP4G
-
No visible damage to legs, braces. Std. RP54 9.16.1
-
All welds in good condition. Std. RP54 9.2.4
-
Ladders in good condition and properly positioned. Std. RP54 9.3.1-2
-
Board properly mounted and in good condition. Std. RP54 9.2.17
-
Board fingers in good condition and snubbed. Std. RP54 9.2.17
-
Board rails in good condition and snubbed. Std. RP54 9.2.17
-
Rod board properly mounted and in good condition. Std. RP54 9.2.17
-
Rob board fingers in good condition and snubbed. Std. RP54 9.2.17
-
Rob board rails in good condition and snubbed. Std. RP54 9.2.17
-
Derrick climber and counter weight installed & properly anchored. Std. 1910.132
-
Derrick climber available at floor when Derrick is raised. Std. 1910.27(d)(5)
-
Derrick free of loose objects. Std. RP54.8.2.5
-
All board hinge points free traveling and lubricated. Std. RP54 9.2.4
-
Derrick stabilizer on scoping cylinder in good condition. Std. RP54 9.2.4
-
Insure Derrick latch dogs are in place and flagged.
-
Crown sheaves guards in place and in good condition. Std. RP54 9.7.5
-
All pins in place W/ safety pins in place. Std. RP54 9.2.8
-
Tail pin screws not screwed out over 6 inches of threads. Std. BP H/L TBL 5
-
Check all hydraulic cylinders for leaks.
-
Purge air from hydraulic rising cylinders.
-
No loose objects left in Derrick; transfers, rod shucks, chains, etc. inventory tools taken into Derrick. Std. RP54 8.2.5
-
All tie back ropes secured when not in use. Std. BP H/L TBL 5
-
All light fixtures class 1-zone 2 rating. Std. 1910.307.b.1
-
All lights secured with safety cables. Std. RP54 9.3.1
-
No splices. Std. 1910.305
-
CGB's (cord grip bushing) in place on all lights and electrical connections. Std. 1926.403
-
Additional Comments
Carrier
-
Handrails and steps installed, secured with pins, and in good condition. Std. 1910.23
-
Toe boards in place on hand rails. Std 1910.23
-
All belts and fans guarded. Std. 1910.212
-
Wheels chocked. Std. RP54 11.1.2
-
Fuel tanks labeled- no smoking, flammable. Std. 1910.145(c)(2)(I)
-
No fuel leakage. Std. OSHA 14.2J
-
Tires and wheels in good condition. Std. OSHA 14.2E
-
Hydraulic leveling jacks in use. Std. OSHA 14.2G
-
Hydraulic leveling jacks secured with lock nuts. Std. OSHA 14.2H
-
Good foundation under jacks.
-
No loose or flammable material stored in cab, no starting fluid. Std. OSHA 14.1A
-
Glass and mirrors in good condition. Std. 1926.50A/R
-
Cab and carrier up to DOT specs, w/ current cert. (if required) Std. KWS
-
Emergency equipment- kill switch available & functional reflectors available or flares. Std. BP safety manual 5.1-2
-
Unit grounded w/ solid copper rod or to we'll head. Std. 1926.954
-
Seatbelt functional. Std. DWOP3.1.4
-
High noise areas posted. Std. DWOP 3.3.2
-
All vessels labeled as to their contents. Std. 1910.12
-
Additional Comments
Draw works
-
All guards in place. Std. RP54 9.4.2
-
Drum guard in place to protect employees, their clothing & equipment from fouling in drum. Std. RP54 9.4.2
-
Tubing line is in good condition. Std. 1910.184
-
Date Installed
-
Wire rope management system in place on tubing line etc. Std. API RP4G
-
Swab line in good condition. Std. 1910.184
-
Date Installed
-
Sufficient wraps on tubing drum 5 @ ground 7 @ floor. Std. OSHA insp.
-
2 1/2-3 wraps on dead,one anchor, correctly wrapped, clamp secured, retainer and guard bolts in place. Std. BP H/L Policy
-
Hydrostatic brake-check for leaks, good condition, anti-freeze protected. Std. OSHA Policy
-
No cathead in use. Std. BP H/L Policy
-
Brakes and brake linkage in good condition, pins secured. Std. OSHA Policy
-
Proper brake linkage adjustment. Std. BP H/L Policy
-
Brake assembly parts meet or exceed OEM specs. Std. DWOP 8.14
-
Assure road gear lockout. Std. RP54 11.1.2
-
Winch line in good condition. Std. 1910.184
-
Date Installed
-
Grade 8 chain in use for all lifting operations & rigged properly & tagged correctly. Std. 1910.184
-
Proper hooks on all lifting chains. Std. 1910.184
-
Crown-o-matic inspected and tested. Std. DWOP 8.3
-
Certified lift eye on sand line. Std. BP H/L 3.1
-
Additional Comments
Operator station/work platform/floor
-
All controls labeled properly. Std. OSHA Insp
-
Kill switch available, functional, and protected. Std. OSHA Insp.
-
Authorized personnel only. Std. 1910.145
-
Work floor level and properly supported and secured w/ cert tag. Std. OSHA Insp.
-
Work floor support cables with factory eyes and approved clevis's. Std. 1910.184
-
All guard rails and hand rails in place and secure. Std. 1910.23(c)(1)
-
Support/suspension pins installed w/ keepers (no bolts) Std. OSHA Insp.
-
Minimum of two stairways to floor. Std. RP54 9.3.10
-
All stairs secured. Std. 1910.36
-
Additional Comments
Racking Board & Diving Board
-
Guard rails in good condition and pinned, when in use. Std. 1910.23(c)(1)
-
Holes in floor covered. Std. 1910.23(a)(8-9)
-
Good foundation under racking boards 3x12's. Std. RP4G 15.1
-
Additional Comments
Power Tongs
-
Safety gate in place and functional. Std. RP54 6.8.3
-
Back up-proper type in place. Std. RP54 9.9.4
-
Stiff arm & snub line, clamps in place and in good condition. Std. RP54 9.9.4
-
Tong head guard in place and in good condition. Std. RP54 6.8.3
-
Hoses and fittings in good condition, no leaks. Std. RP54 9.9.9
-
Tong support line in good condition. Std. 1910.184
-
Tong safety hanger in good condition. Std. 1910.184
-
Additional Comments
Traveling Assembly
-
Blocks in good condition. Std. RP54 9.7.1
-
Sheave guards in place. Std. RP54 9.7.4
-
Hook in good condition, lock in good condition. Std. RP54 9.7.1
-
Elevator links in good condition. Std. RP8B
-
Annual insp. date.
-
Elevators in good condition. Std. RP8B
-
Annual insp. date.
-
Rod hooks-latching and spring mechanism wear. Std. RP8B CAT. IV
-
Annual insp. date.
-
Transfer elevators in good condition-safety latches & transfer line in good condition. Std. RP54 9.7.1
-
Annual insp. date.
-
Transfer pickup eye in good condition, nut lock pin in place. Std. RP54 9.7.1
-
All bolts in place in side covers on blocks. Std. RP54 9.7.1
-
All bolts in place on all traveling equipment & tight. Std. RP54 9.7.1
-
Load rated rod transfer w/ safety latch in place. Std. BP H/L Policy
-
Rod transfer eye bolt nuts keyed. Std. Manfct. Spc.
-
No weight bars hung off rod board. Std. BP S.M. 3.4.4
-
Additional Comments
Circulating systems
-
Standpipe secured to Derrick. Std. RP54 8.a
-
Rotary hose secured both ends, top end to Derrick. Std. API 7K-7L
-
High pressure fittings on all connections. Std. 1910.169
-
Safety relief valve in place and set properly. Std. 1910.169
-
Relief line properly anchored. Std. 1910.169
-
Pump guards in place. Std. 1910.212
-
Mud pit walkways and stairs in good condition & anchored. Std. 1910.22-23
-
Mud mixing area, all ppe in place. Std. 1910.132
-
Additional Comments
Well Control Equipment
-
Assure test chart for all BOPE. Std. RP54 6.4.1
-
All bolts in place in all flanges. Std. RP54 6.4.1
-
Check all ring grooves and rings. Std. RP54 6.4.1
-
Floor valve in place w/ proper x-over. Std. RP54 6.4.2
-
Accumulator properly installed-no leaks. RP54 6.4.1
-
Cover over blind/shear ram control handle. Std. RP53 12.5.3.f
-
Hydraulic system charged. Std. RP54 6.4.1
-
Controls labeled. Std. RP54 6,4,1
-
All BOPE tested and functional. Std. RP54 6.4.1
-
BOP control lines and valves identified. Std. RP54 6.4.11
-
All unused accumulator lines capped. Std. RP54 6.4.18
-
Accumulator lines in open/closed position. Std. BP S.M. 5 1-2
-
Additional Comments
Safety Equipment
-
Fire extinguishers minimum 30 lb. min. 2, located at guy line anchors. Std. 1910.157
-
Personal protective equipment in use, std. RP54 5.2.3
-
No loose clothing. Std. 1910.132(a)
-
Gloves. Std. 1910.132(a)
-
Hard hat worn by all (plastic). Std. RP54 5.2.1
-
Safety glasses. Std. RP54 5.2.2
-
Steel toe boots. Std. RP54 5.2.3
-
Fire retardant clothing(FRC). Std. BP Policy
-
Visitor hard hat and safety glasses required. Std. 1910.132(a)
-
Additional Comments
Procedures In Place
-
Crews trained in JSA Program. Std. RP54 6.1.7
-
JSA program in use w/ written JSA's in place. Std. RP546.1.7
-
Emergency plan in place and understood by all employees. Std. 1910.38.b
-
Golden rules understood by all employees. Std. BP Policy
-
Stop program in place and in use(observation program). Std. DWOP 3.1.3
-
LOTO in place and utilized. Std. 1910.417
-
SDS/SPCC plan in place and current. Std. BP S.M. 5.1-2
-
Tool pusher and driller BOP certified. Std. DWOP 15.2
-
First aid/CPR 2 per crew w/ cert. card. Std. RP54 4.3.1
-
No jewelry policy. Std. BP S.M.
-
Full body harness available. Std. 1910.66
-
"Y" lanyards available. Std. 1910.66
-
Auxiliary lifting equipment register on-site ( wire rope, chains, hooks, chuckles). Std. BP H/L Policy
-
Additional Comments