Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
1. Layout
-
Area is clean, tidy and well kept.
-
Adequate storage area provided.
-
Floor is free of obstructions and slip resistant.
-
There is adequate ventilation.
2. Emergency Procedures
-
Clearly Written evacuation procedures and exits displayed
-
Are spill kits available?
-
Portable fire extinguishers have been provided and maintained.
-
White Cross information on health and safety notice board
-
Emergency and hazard signage is clearly visabale
3. Emergency Systems and First Aid facilities
-
Randomly ask if employees are familiar with relevant emergency response procedure
-
Emergency exits clearly marked and unobstructed
-
Evacuation and assembly points known by all staff
-
Wardens appointed and trained
-
At least one trained First Aider on each floor at time of inspection
-
First Aid kits fully stocked, accessible and identified by signage
-
Staff know name of their First Aider
-
Staff know location of nearest defibrillator
-
Check the pads not expired
-
Check to see if power level light on defibrillator is on
-
Fire extinguishers were serviced in the last 12 months
-
Fire wardens all have clean Hi Viz jackets
-
All staff know where to find after hours security number
4. General Facilities
-
Washing facilities are clean and functional.
-
Are stairs, passageways and store rooms well lit?
-
Warning and Safety signage in good condition.
-
Isolation valves are readily accessible and clearly labelled.
-
Check Health and Safety notice board is current with fire warden and first Anders contact details are available
5. Manual Handling
-
where applicable manual handling Standard Operating Procedures (SOP) are available.
-
Personnel in inspection area are inducted and trained in manual handling.
-
trolleys or mechanical hoists are available and are being considered for heavy items or loads.
6. Storage
-
Materials stored in racks and bins wherever possible are not above shoulder height.
-
Storage designed to minimize lifting problems I.e. heavy objects not stored on upper racks.
-
Racking securely fixed to the floor or wall.
-
Safe lifting sign displayed.
7. Slips and Trips
-
Warning signs are available if a spill was to occur
-
There are special provisions for slip resistance in wet areas.
-
handrails and slip resistance are provided on ramps and stairs.
-
Walkways are free of hazards, such as electrical leads.
8. Electrical Safety
-
all portable equipment has current test tags.
-
Residual current devices (RCD) are installed at switchboards or fixed into sockets. (It should be clearly marked on socket).
-
Portable RCD device is available and has been tested.
-
Flexable cord, plugs ad extension leads are in good condition and have either moulded or transparent type plugs.
-
Power points are suitable for the location and are positioned safely.
-
Power boards are used. (not double adapters).
-
Faulty equipment is tagged out. (Tag and tags is available).
9. Chemical Aspects
-
MSDS (not older older than 5 years) are available for workers reference and included in the hazardous substances register.
-
there is an up to date easy to find and read list/register summary of all chemicals used.
-
A risk assessment has been completed for all chemicals and harmful substances stored and used at the workplace.
-
decanted containers are labeled with name, risk and safety instructions.
-
Original containers have the manufacturer's label.
-
Chemicals stored according to compatibility and bundled i.e. in flammable or corrosive cabinets.
-
Are minimal amounts of corrosives stored, and/or used?
-
Only flammables stored in flammable liquid cabinet?
-
Are the warning signs on the cabinet legible? (e.g. DG Class 3 diamond, no smoking, no ignition sources).
10. Personal Protective Equipment
-
Instruction and information of PPE are available.
-
signage of PPE requirements displayed on equipment.
-
General P.P.E. Signage when entering areas.
11. Noise
-
A risk assessment on noise has been conducted where it is likely that workers Re exposed to noise levels.
-
workers have received information and training in relation to noise at the workplace.
12. Machinery and Plant
-
Records are kept of maintenance, alterations and inspections.
-
Load chart is provided and legible.
-
Keys are not left behind in unattended mobile plant.
-
Are S.O.P's warning signs clearly visible?
-
Work area is organized for the safety of the mobile plant operator and pedestrians. (Safe walkways on floor?)
-
Forklift operators hold a high risk work license for forklift operation and have reached 18 years of age.
-
Pre-start safety check of machinery/mobile plant is carried out
-
Are records of training held for appropriately trained people?
-
Emergency stops tested andc are working.
13. Guarding
-
Operators and maintenance personnel properly trained, familiar with the operation and set up of machinery and able to demonstrate safety features, as per the S.O.P.
-
Guards protect against hazards to the rear and sides of machinery.
-
Pre-operational checks are conducted to ensure safety features are in working order.
-
If machine is fitted with an Emergency Stop is it clearly marked
-
where it is not practical to provide guarding and people are required to operate or pass close to dangerous moving parts, a safe system of work in place to reduce risk.
14. Welding Safety
-
Are staff appropriately trained and inducted in the dangers of performing welding tasks and is it documented
-
Are students appropriately supervised by a competent person when welding?
-
are welding operators provided with the appropriate PPE?
-
Is there adequate ventilation for welding tasks?
-
Are there appropriate warning signs in welding areas?
-
Are welding screens used when performing welding tasks?
-
Are ventilation systems working adequately?
15. Compressed Gas
-
Cylinders contents are identified and appropriately secured.
-
cylinders are stored according to dangerous goods class and empty cylinders are separated from full ones.
-
Gas lines are free of leaks, kinks, wear & tear and connections in good repair.
Other Hazards
-
Other hazards
Please sign and email the report to the OSH Coordinator.
-
Select date
-