Information
-
Document No.
-
Wind Turbine Condition Assessment
-
Challicum Hills
-
Clements Gap Wind Farm
-
Codrington
-
Portland II Wind Farm (Cape Bridgewater)
-
Portland III Wind Farm (Cape Nelson South)
-
Portland IV Wind Farm (Cape Sir William Grant)
-
Portland IV Wind Farm (Cape Nelson North)
-
Yambuk
-
WTG Number
-
Conducted on
-
Prepared By
-
Other auditor?
-
Location
WTG Base and Hardstand (external)
-
Area free of trip hazards and contaminants?<br>
-
Add media
-
Tower/Foundation Connection condition (Bolts or Embedded)?
-
-
Grout/Sealant around WTG Base (intact and without significant cracking - take measurement pic)?<br>
-
Add media
-
Tower free of corrosion or other paint defects?<br>
-
Add media
-
Steps in good condition, level and earthed?
-
Add media
-
WTG Door in good condition, vents secure and in good condition, filters in place, latch operating?<br>
-
Add media
-
Any other issues?
-
Kiosk (where applicable), Switchgear and Tx
-
Kiosk enclosure condition (Corrosion or damage of Louvres, Doors, Roof, Lifting points, signage)? (where applicable)
-
-
Kiosk Settlement/Erosion?
-
-
Transformer in good condition, (corrosion, oil leaks, cooling fins, temps, LV/HV cables)?<br>
-
Add media
-
Area free of dust, vermin, corrosion?<br>
-
Add media
-
Voltage Indicator Neons operating?<br>
-
Add media
-
SF6 Gas level OK?<br>
-
Add media
-
LV Cable terminations?
-
-
HV Cable terminations?
-
-
Any other issues?
-
Turbine basement (Inside ground level)
-
Free of vermin? <br>
-
Add media
-
Earth cables attached to tower earth bar and tight?<br>
-
Add media
-
Area clean and dry?<br>
-
Add media
-
Fire extinguisher in date? Emergency signage in place? <br>
-
Add media
-
Signage in good order?<br>
-
Add media
-
Any other issues?
-
Ladder
-
Ladder inspection in date? Ladder secured to floor?
-
Add media
-
Ladsafe system inspection/certification in date?
-
-
Climb assist operating?
-
Add media
-
Any other issues?
-
WTG Control panel and floor level
-
Panel door interlocks not bypassed?<br>
-
Add media
-
All safety panels fitted? <br>
-
Add media
-
Wiring secured and in place<br>
-
Add media
-
Air filters in place?<br>
-
Add media
-
All panels fully secured?
-
Add media
-
All glands tight? All spare gland holes plugged?<br>
-
-
Area clean?
-
Add media
-
Any other issues?
-
Power Factor Correction (PFC Turbine only)
-
Floor level clean?<br>
-
Add media
-
PFC Cabinet in good order?
-
Add media
-
Capacitors - Failed units?
-
-
Tower section lights working, covers OK
-
Add media
-
Anchor points in good condition? (where applicable)<br>
-
Add media
-
Any other issues?
-
First level floor
-
Floor level clean?
-
Add media
-
Ladder in good order?
-
Add media
-
Ladder Hatches OK?<br>
-
Add media
-
Anchor points in good condition? <br>
-
Add media
-
Bolted flange OK?<br>
-
Add media
-
Earth connections between flanges fitted and tight?<br>
-
Add media
-
Cable clamps secure? Cable insulation undamaged?
-
Add media
-
Junction box in good order (where applicable)?
-
Add media
-
GPO on Ladder in good condition?
-
Add media
-
Tower section lights working, covers OK?
-
Add media
-
Any other issues?
-
Second level floor
-
Floor Level Clean?<br>
-
-
Ladder in good order?<br>
-
Add media
-
Ladder Hatches OK?
-
Add media
-
Anchor points in good condition?
-
Add media
-
Bolted flange OK?
-
-
Earth connections between flanges fitted and tight? <br><br>
-
Add media
-
Cable clamps/support configuration secure? Cable insulation undamaged?<br>
-
Add media
-
Cable "waterfall" in good condition? (Turbine wall to centre point)
-
Add media
-
Junction box in good order (where applicable)?
-
-
GPO on Ladder in good condition?
-
Add media
-
Tower section lights working, covers OK?
-
-
Any other issues?
-
Dampener level floor (where applicable)
-
Floor Level Clean?
-
-
Ladder in good order?
-
Add media
-
Ladder Hatches OK?
-
Add media
-
Anchor points in good condition?
-
-
Cable clamps/support configuration secure? Cable insulation undamaged?
-
Add media
-
Junction box in good order (where applicable)?
-
-
GPO on Ladder in good condition?
-
-
Any other issues?
-
Third (Yaw) level floor
-
Floor Level Clean?
-
-
Ladder in good order?
-
-
Ladder Hatches OK?
-
-
Anchor points in good condition?
-
-
Tower section lights working, covers OK?
-
-
Tower/Yaw connection OK (bolted and tower welded flange))?
-
-
Earth connections between flanges fitted and tight?
-
-
Yaw bearing in good condition?<br>
-
Add media
-
Yaw gear in good condition?
-
-
Yaw Bearing/Gear Automatic Lubrication system operating ok?
-
-
Yaw Brakes not leaking (where applicable)?
-
Add media
-
Yaw Brakes not slipping (where applicable)?<br>
-
Add media
-
Yaw Motor pinions in good condition (where applicable)?
-
-
Any other issues?
-
Nacelle
Yaw Motors and Nacelle entry
-
No loose fittings?
-
Add media
-
No oil or grease leaks?<br>
-
Add media
-
Paint work in good condition?
-
Add media
-
Yaw drives do not make any abnormal noise?<br>
-
Add media
-
Any other issues?
-
Add media
Main shaft and bearing
-
Main bearing in good order, no excess grease?
-
Add media
-
Any other issues?
-
Gearbox
-
Mounting points in good condition?
-
Add media
-
Fittings and hoses sound and secure?<br>
-
Add media
-
Oil level OK? No Leaks?<br>
-
Add media
-
No abnormal noises, gearbox teeth OK?<br>
-
Add media
-
Any other issues?
-
High speed shaft and slip ring
-
Guards fitted and secure?<br>
-
Add media
-
Shaft brake appears OK?<br>
-
Add media
-
High Speed shaft in good condition?<br>
-
Add media
-
Slip ring in good condition
-
Add media
-
Floor area clear of combustible materials such as rags etc.
-
Add media
-
Any other issues?
-
Generator
-
Panels secure?<br>
-
Add media
-
Earths fitted and tight?<br>
-
Add media
-
Any other issues?
-
Add media
Control Panel
-
Cabinet neat and tidy
-
Add media
-
Glands tight and gland holes plugged?
-
Add media
-
Door filters in place?
-
Add media
-
Wiring OK?
-
Add media
-
Any other issues?
-
Add media
General Nacelle area
-
Service Hoist operating and hook in good order?<br>
-
Add media
-
Fire extinguisher in date?<br>
-
Add media
-
Rescue kit sealed?<br>
-
Add media
-
Area clean?<br>
-
Add media
-
No trip hazards?<br>
-
Add media
-
No missing/loose bolts from nacelle roof flange?<br>
-
Add media
-
No signs of leaks or ingress of rain into Nacelle?<br>
-
Add media
-
Lights working, Covers OK?<br>
-
Add media
-
Any other issues?
-
Add media
Nacelle roof level
-
No corrosion on fittings?<br>
-
-
Radiator OK?<br>
-
Add media
-
Anemometers/Wind Vanes OK?
-
Add media
-
Access hatches OK?
-
Add media
-
Anchor points in good condition?
-
Add media
-
Any other issues?
-
Add media
Hub and Blades
-
No grease leaks or damaged seal Blade A?<br>
-
Add media
-
No grease leaks or damaged seal Blade B?<br>
-
Add media
-
No grease leaks or damaged seal Blade C?<br>
-
Add media
-
Blade "A" pitch 0-90 degress no abnormal noise<br>
-
Add media
-
Blade "B" pitch 0-90 degress no abnormal noise<br>
-
Add media
-
Blade "C" pitch 0-90 degress no abnormal noise
-
Add media
-
Anchor points in good condition?
-
Add media
-
Hub Hatches OK?<br>
-
Add media
-
Pitch rams appear OK (where applicable)?<br>
-
Add media
-
Pitch motors appear OK (where applicable)?
-
-
No Loose items or bolts?<br>
-
Add media
-
Hub Clean and free of damage?<br>
-
Add media
-
Any other issues?
-
Add media
Condition Assessment Sign Off
-
Authorised Contractor Rep:
-
Authorised Owner Rep: