Information

  • Document No.

  • Wind Turbine Condition Assessment

  • Challicum Hills

  • Clements Gap Wind Farm

  • Codrington

  • Portland II Wind Farm (Cape Bridgewater)

  • Portland III Wind Farm (Cape Nelson South)

  • Portland IV Wind Farm (Cape Sir William Grant)

  • Portland IV Wind Farm (Cape Nelson North)

  • Yambuk

  • WTG Number

  • Conducted on

  • Prepared By

  • Other auditor?

  • Location

WTG Base and Hardstand (external)

  • Area free of trip hazards and contaminants?<br>

  • Add media

  • Tower/Foundation Connection condition (Bolts or Embedded)?

  • Grout/Sealant around WTG Base (intact and without significant cracking - take measurement pic)?<br>

  • Add media

  • Tower free of corrosion or other paint defects?<br>

  • Add media

  • Steps in good condition, level and earthed?

  • Add media

  • WTG Door in good condition, vents secure and in good condition, filters in place, latch operating?<br>

  • Add media

  • Any other issues?

Kiosk (where applicable), Switchgear and Tx

  • Kiosk enclosure condition (Corrosion or damage of Louvres, Doors, Roof, Lifting points, signage)? (where applicable)

  • Kiosk Settlement/Erosion?

  • Transformer in good condition, (corrosion, oil leaks, cooling fins, temps, LV/HV cables)?<br>

  • Add media

  • Area free of dust, vermin, corrosion?<br>

  • Add media

  • Voltage Indicator Neons operating?<br>

  • Add media

  • SF6 Gas level OK?<br>

  • Add media

  • LV Cable terminations?

  • HV Cable terminations?

  • Any other issues?

Turbine basement (Inside ground level)

  • Free of vermin? <br>

  • Add media

  • Earth cables attached to tower earth bar and tight?<br>

  • Add media

  • Area clean and dry?<br>

  • Add media

  • Fire extinguisher in date? Emergency signage in place? <br>

  • Add media

  • Signage in good order?<br>

  • Add media

  • Any other issues?

Ladder

  • Ladder inspection in date? Ladder secured to floor?

  • Add media

  • Ladsafe system inspection/certification in date?

  • Climb assist operating?

  • Add media

  • Any other issues?

WTG Control panel and floor level

  • Panel door interlocks not bypassed?<br>

  • Add media

  • All safety panels fitted? <br>

  • Add media

  • Wiring secured and in place<br>

  • Add media

  • Air filters in place?<br>

  • Add media

  • All panels fully secured?

  • Add media

  • All glands tight? All spare gland holes plugged?<br>

  • Area clean?

  • Add media

  • Any other issues?

Power Factor Correction (PFC Turbine only)

  • Floor level clean?<br>

  • Add media

  • PFC Cabinet in good order?

  • Add media

  • Capacitors - Failed units?

  • Tower section lights working, covers OK

  • Add media

  • Anchor points in good condition? (where applicable)<br>

  • Add media

  • Any other issues?

First level floor

  • Floor level clean?

  • Add media

  • Ladder in good order?

  • Add media

  • Ladder Hatches OK?<br>

  • Add media

  • Anchor points in good condition? <br>

  • Add media

  • Bolted flange OK?<br>

  • Add media

  • Earth connections between flanges fitted and tight?<br>

  • Add media

  • Cable clamps secure? Cable insulation undamaged?

  • Add media

  • Junction box in good order (where applicable)?

  • Add media

  • GPO on Ladder in good condition?

  • Add media

  • Tower section lights working, covers OK?

  • Add media

  • Any other issues?

Second level floor

  • Floor Level Clean?<br>

  • Ladder in good order?<br>

  • Add media

  • Ladder Hatches OK?

  • Add media

  • Anchor points in good condition?

  • Add media

  • Bolted flange OK?

  • Earth connections between flanges fitted and tight? <br><br>

  • Add media

  • Cable clamps/support configuration secure? Cable insulation undamaged?<br>

  • Add media

  • Cable "waterfall" in good condition? (Turbine wall to centre point)

  • Add media

  • Junction box in good order (where applicable)?

  • GPO on Ladder in good condition?

  • Add media

  • Tower section lights working, covers OK?

  • Any other issues?

Dampener level floor (where applicable)

  • Floor Level Clean?

  • Ladder in good order?

  • Add media

  • Ladder Hatches OK?

  • Add media

  • Anchor points in good condition?

  • Cable clamps/support configuration secure? Cable insulation undamaged?

  • Add media

  • Junction box in good order (where applicable)?

  • GPO on Ladder in good condition?

  • Any other issues?

Third (Yaw) level floor

  • Floor Level Clean?

  • Ladder in good order?

  • Ladder Hatches OK?

  • Anchor points in good condition?

  • Tower section lights working, covers OK?

  • Tower/Yaw connection OK (bolted and tower welded flange))?

  • Earth connections between flanges fitted and tight?

  • Yaw bearing in good condition?<br>

  • Add media

  • Yaw gear in good condition?

  • Yaw Bearing/Gear Automatic Lubrication system operating ok?

  • Yaw Brakes not leaking (where applicable)?

  • Add media

  • Yaw Brakes not slipping (where applicable)?<br>

  • Add media

  • Yaw Motor pinions in good condition (where applicable)?

  • Any other issues?

Nacelle

Yaw Motors and Nacelle entry

  • No loose fittings?

  • Add media

  • No oil or grease leaks?<br>

  • Add media

  • Paint work in good condition?

  • Add media

  • Yaw drives do not make any abnormal noise?<br>

  • Add media

  • Any other issues?

  • Add media

Main shaft and bearing

  • Main bearing in good order, no excess grease?

  • Add media

  • Any other issues?

Gearbox

  • Mounting points in good condition?

  • Add media

  • Fittings and hoses sound and secure?<br>

  • Add media

  • Oil level OK? No Leaks?<br>

  • Add media

  • No abnormal noises, gearbox teeth OK?<br>

  • Add media

  • Any other issues?

High speed shaft and slip ring

  • Guards fitted and secure?<br>

  • Add media

  • Shaft brake appears OK?<br>

  • Add media

  • High Speed shaft in good condition?<br>

  • Add media

  • Slip ring in good condition

  • Add media

  • Floor area clear of combustible materials such as rags etc.

  • Add media

  • Any other issues?

Generator

  • Panels secure?<br>

  • Add media

  • Earths fitted and tight?<br>

  • Add media

  • Any other issues?

  • Add media

Control Panel

  • Cabinet neat and tidy

  • Add media

  • Glands tight and gland holes plugged?

  • Add media

  • Door filters in place?

  • Add media

  • Wiring OK?

  • Add media

  • Any other issues?

  • Add media

General Nacelle area

  • Service Hoist operating and hook in good order?<br>

  • Add media

  • Fire extinguisher in date?<br>

  • Add media

  • Rescue kit sealed?<br>

  • Add media

  • Area clean?<br>

  • Add media

  • No trip hazards?<br>

  • Add media

  • No missing/loose bolts from nacelle roof flange?<br>

  • Add media

  • No signs of leaks or ingress of rain into Nacelle?<br>

  • Add media

  • Lights working, Covers OK?<br>

  • Add media

  • Any other issues?

  • Add media

Nacelle roof level

  • No corrosion on fittings?<br>

  • Radiator OK?<br>

  • Add media

  • Anemometers/Wind Vanes OK?

  • Add media

  • Access hatches OK?

  • Add media

  • Anchor points in good condition?

  • Add media

  • Any other issues?

  • Add media

Hub and Blades

  • No grease leaks or damaged seal Blade A?<br>

  • Add media

  • No grease leaks or damaged seal Blade B?<br>

  • Add media

  • No grease leaks or damaged seal Blade C?<br>

  • Add media

  • Blade "A" pitch 0-90 degress no abnormal noise<br>

  • Add media

  • Blade "B" pitch 0-90 degress no abnormal noise<br>

  • Add media

  • Blade "C" pitch 0-90 degress no abnormal noise

  • Add media

  • Anchor points in good condition?

  • Add media

  • Hub Hatches OK?<br>

  • Add media

  • Pitch rams appear OK (where applicable)?<br>

  • Add media

  • Pitch motors appear OK (where applicable)?

  • No Loose items or bolts?<br>

  • Add media

  • Hub Clean and free of damage?<br>

  • Add media

  • Any other issues?

  • Add media

Condition Assessment Sign Off

  • Authorised Contractor Rep:

  • Authorised Owner Rep:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.