1. The Safety Management Manuals
-
Company policy, drug &alcohol policy and instructions are properly displayed & records maintained for all personnel on boars
-
SMS Manuals are available as indicated in the distribution list- Updated hard copies of BDPM,ERPM,ECP, SOPEP/SMPEP, CHM, CSM in relevant locations.<br>
-
Current revision is available on board and on the ship's network
-
Are all on board familiarized with the company SMS and updates & revisions.
-
Emergency organizations/ERS/ National operational contact details available?
-
DPA/CSO Contact numbs available & posted?
2. Documentation
2.1 Ship's Certificates (attach list)
-
Are the ship's certificates arranged and filed in accordance with SMM7 App2?
-
Are the ship's certificates valid & current
-
List the certificates expiring within next 3 months.
2.2 Library, Publications, Technical documentation
-
List of publications is current & Maintained
-
Conventions, IMO publications, rules & regulations and technical guidance books, as listed in the SMS manuals area available?
-
Nautical publications, code of signals, etc... As listed in the SMS manuals are available
-
Technical manuals and drawings are available?
-
Manuals, documents and instructions requested by compulsory requirements or by the company as listed in the SMS manuals are available. Class approved manuals : Loading & stability, damage stability, SOPEP/ SMPEP, ODMCS, IGS, CSM, P&A manual (As applicable)
2.3 The following Records are updated and in order
Maintenance
-
A. PMS - Engine & Deck Machinery (List no. Of overdue jobs)
-
B. CMS (No Overdue Jobs)
-
C. Inspection of cargo tanks, ballast tanks, void spaces and cofferdams.
-
D. Fire fighting & Life saving appliances
-
E. Bridge equipment & Systems
-
F. Automation
-
Fuel & Lube oil Analyses reports (last report date)
-
Are Lube oil Analyses carried out at specified intervals?
-
Are recommendations (if any) followed up?
-
Tests & Drills register (include last 2 dates)<br>1. Abandon ship drill<br>2. Fire drill<br>3. Lowering of L/B & R/B<br>4. Emergency steering drill<br>5. MOB drill<br>6. ISPS drill<br>7. SOPEP/ SMPEP drill
Familiarizations
-
Prior to sailing familiarization carried out?
-
Bridge equipment familiarization carried out prior taking over the Bridge Watch?
-
Engine room Familiarization carried out prior taking over an engine watch?
-
14 days Safety Familiarizations carried out?
-
Hygiene/ Sanitary inspections carried out? (Health & Safety Inspections)
-
Pump room entry permits correctly recorded (If applicable)
-
Enclosed Space entry permits, correctly recorded?
-
Hot work permits, including Company notifications/ permissions & associated RA's
-
Working aloft/ outboard permits correctly recorded?
-
Electrical isolation permits correctly recorded?
2.4 Correspondence and other documentation files
-
Master/Chief Engineer/ Chief Officer Reports at relief
-
Other correspondence with regard to the SMS follow up<br>1. N/C reports and follow up in SMART<br>
-
2. Master's review & follow up available?
-
3. internal audits and follow up available?
-
4.?Superintendent's HIT- Lists and follow up
2.5 Spare parts & Materials
-
Requisitions from the ship have been addressed?
-
Spare parts and material inventories are maintained?
-
In case of "Customer supplied equipment", are adequate records of maintenance and spares available?
2.6 Company/ IMO/ Flag State Circulars/ Letters
-
Circulars duly filed and circulated/ discussed?
-
An index is provided for those still valid and those not in force have been removed?
3.1 Ship's Personnel
-
The crew list and certification complies with the Safe Manning Document. (Compare with the operational STCW levels mentioned in the SMD)
-
Officer's and crew's certificates comply with STCW and Flag State requirements, including Flag State dangerous cargo endorsements for the specific Management/ Operational Levels
-
Crew training records maintained?
-
Watch arrangements are updated & displayed in the correct format?
-
Rest hours are maintained and in compliance. Monthly exports sent to the office?
-
Records of D&A tests are maintained?
3.2 Language and Nationalities
-
Officers and crew can communicate in ENGLISH?
-
Senior Officers have a good knowledge of the English Language?
3.3 Duties
-
The Master has delegated some of his duties.<br>A) written communication available<br>B) Standing orders and Night Orders available and signed.
-
The Chief Engineer has delegated some of his duties.<br>A) written communication available<br>B) Standing orders and Night Orders available and signed.
3.4 Shipboard Organization
Safety & Environment Committee/ Team
-
SEP Meetings are held in accordance with the SMM (Monthly)
-
Minutes of the meetings are available on board and are in accordance with the agenda in SMM?
-
Evidence of crew participation in the SEP meetings?
-
SEP meeting to be held on board, Auditor to participate in the meeting.
-
Is the vessel provided with updated legal and other information that the organization subscribes to?
-
Company KPI and vessel's performance regularly compared and evaluated?
4.1 Safety/ Environment Management
-
Is the DPA known to the Master & Key personnel?
-
Is the role of The DPA knpwn to key personnel?
-
Aid the Master aware of his overriding authority as per ISM code?
-
Is the Master clear of this authority to request Company assistance as may be necessary?
-
Sufficient crew are on board to deal with emergencies?
-
Muster Lists/ Emergency instructions are updated including substitutes for key personnel?
-
IMO Safety precautions are displayed, IMO safety signage satisfactory?
-
Electric and gas welding equipment are in good condition?
-
Acetylene and Oxygen bottles are stowed in separate compartments?
-
Environmental targets and programs monitored and reviewed?
-
Is C/E (The Environmental Officer) aware of his duties in accordance with the EMM?
-
Crew Training in EMM Conducted?
4.2 Accidents, near misses and hazardous situations, Risk Assessments
-
SMART reports are issued for accidents, Near Misses, Hazardous situations and Failures that have occurred?
-
Follow up of reports and adequate close out is available?
-
Vessel has reported Near miss situations and other proactive reporting, including suggestions for improvement?
-
Risk assessments are performed as required by the SMS and is the structured Risk Assessment methodology used to identify potential hazards?
4.3 Company inspections on ships
-
Date of last inspection.
-
Interval of inspections is in accordance with the SMS?
-
Copy of the inspection reports or list if non - conformities is available?
-
Communication from e Ship's command to the company when defects have been corrected are available? (Follow up of hit lists)
4.4 Company Audits on Ships
-
Date of the last Company Internal audit.___________
-
Date of last Master's Review and follow up.
-
Intervals of the Internal Audits is in accordance with the SMS?
-
Company audit reports and or list of non conformities is available?
-
Communication from e Ship's command to the company when non conformities have been corrected are available
4.5 Class Audits
-
Date of Last Audit___________
-
Class Audit reports or list of non conformities available.
-
Communication from ship's command to the company when non conformities have been corrected available.
4.6 Port State Control / Vetting / Inspections
-
date and place of last Port State Control Inspection.<br>Observations from last PSC Inspection adequately addressed.
-
Vetting Reports and corrective actions followed up and closed.
-
Customer complaints, if any, reported and adequately addressed.
5. Pollution Prevention
5.1 All Ships
5.5.1 Bunkering and fuel transfer:
-
A. Piping diagrams are properly displayed
-
B. Checklists are used for Bunkering and Internal transfer.
-
C. OWS discharges in accordance with requirements<br>
-
D. Sludge handling and records in accordance with requirements
-
E. incinerator operations & recording in accordance with requirements
-
Test and calibration records of OWS are available
-
Anti Pollution scupper plugs are in use and effectively plugged
-
Spill containers and gratings are fitted under bunker manifolds and fuel tank vents, clean and dry and effectively plugged?
-
Unused manifolds are blanked and fully bolted
-
Exposed decks are free from garbage, oil/ oily material, toxic material
-
Means are readily available to deal with small oil spills
-
The Oil Record Book Part I (Machinery Spaces) is complete and up to date.
-
Garbage stored as per Garbage Management Plan and Garbage log book up to date
-
Chemicals
-
Chemicals are properly stowed in designated Chemical Lockers that have restricted access, MSDS are available, PPE available
-
Drills have been conducted as per SOPEP/ ECP
5.2 Tankers
-
Cargo/ Ballast plan has been prepared for current operations, approved by Master and agreed between ship and shore
-
Sip- Shore checklist completed including Repetitive checks
-
No Cargo leakage visible on deck
-
Spill containers and gratings are fitted under cargo manifolds
-
Unused cargo line manifolds are blanked and fully bolted
-
The Cargo/ Ballast pump room bilge high level alarm is working
-
The Cargo Oil Record Book Part II (Oil Tankers), Cargo Record Book (Chemical tankers) is complete and up to date
-
Products hazards (MSDS) and first aid instructions are posted in the crew accommodation
-
Antidotes are available on board for specific cargoes
-
Records of pre- operations checks as per CHM available
6. Life Saving and Fire fighting Equipment
-
The following Ship- Specific manuals, lists and log books are available on board:
-
Training manuals on Life Saving appliances and Fire Safety Training Manual
-
LSA/ FFA instructions, maintenance and records
-
During the general examination of the ship, the following appliances have been visually examined and found in good condition
-
Lifeboats and lowering/ launching arrangements
-
Life rafts: Stowage, securing and elated hydrostatic releases
-
Life buoys and stowage as required
-
Fire detection system and controls, including testing of detectors
-
Fixed CO2/ Foam fighting systems for deck/ pump room/ Engine Room
-
Local water mist systems (as Applicable)
-
Fixed Fire detection and fighting systems for car decks (as applicable)
-
Records of LSA maintenance including On Load release gear
-
Ae lifeboat and life raft operating instructions displayed?
-
The emergency Fire Pump is operational and a maintenance data is available
-
The emergency fire pump is provided with operating instructions?
-
Operating instructions are posted next to fixed fire fighting systems
-
Vent trunk fire flaps and funnel dampers are clearly marked and operational
-
Accommodation ventilation stops are clearly marked and operational
-
Gangways are properly rigged and lighted?
-
A life buoy with SI light and a lifeline is available near the gangway?
-
Life jackets and survival suits are in good condition and regularly checked?
7. Cargo/ Ballast Systems
7.1 Tankers
-
The Sip/Shore checklist (with chemical supplement as required) is completed and provisions are being observed
-
Stress and stability calculations are performed during operations
-
Suitable pipeline diagrams are available?
-
P/V Valves appear in good condition (Check Flame screens)
-
P/V Breaker with adequate amount of liquid (Level clearly visible)
-
Mast Riser flame screens in good condition and mast riser drain is clear?
-
Ballast exchange records maintained as per company requirements
-
Has Cargo/ Ballast plan been prepared for current operations and agreed between ship and shore
-
Cargo handling is being carried out as per agreed plans
Records are available for the testing of:
-
Pump controls, alarms and trips
-
P/v Valves, Mast Risers, IG Non- Return valve, deck seal
-
cargo Piping
-
Inert gas system alarms, trips, calibration of fixed O2 analyzer
-
VECS System, calibration of sensors
-
Portable gas detection equipment (Tests, calibration and records)
-
Fixed Gas Detection system
-
Fixed and portable tank gauging system
-
Tank temperature and pressure sensors, where applicable
-
Portable Cargo/ Tank Cleaning hoses
-
Verification of comparison between manual and automatic gauges
7.2 Pump Rooms
-
Clean and tidy, Free of any visible traces of cargo, oily rags, debris
-
Warning Notices posted?
-
Entry Policy displayed and entry permits recorded
-
EEBD, Stretcher, Ear Protectionavailable
-
Bilge alarms checked and emergency Bilge Pumping arrangements in order
-
FFA available and operational, including light interlock, fire dampers, visual and audible alarms
-
Guard railings, gratings, chains and pump shaft guards in place?
8. Lifting/ Hoisting/ Securing equipment
-
Is Safe Working Load (SWL) clearly marked on all lifting equipment?
-
Ae maintenance records up to date (Register of lifting appliances, PMS)
-
Work Aloft and loose lifting gear regularly inspected, including harness, lifelines, stages, chain blocks, hoists.
-
Appliances for RO-RO,<br>cargo securing equipment adequately maintained, marked and stowed
9. Mooring and Anchoring Equipment
-
Visible part of mooring ropes,/ wires, fire wires, mooring tails, stoppers, mooring shackles are in good condition (Ref BDPM 7.2.2)
-
Have ropes/ wires been reeled in correct direction?
-
Records/ Certificates available for all mooring equipment, identifying locations?
-
Do winch and windlass brake linings and hinge pins appear in good condition.<br>Last BHC test date __________
-
Have rendering arrangements been set to 60% MBL and crew aware of the same
-
Visible parts of anchor, chains and stoppers are in good condition?
-
Decks in mooring areas are painted with non-skid paint?
10. Bridge Equipment and Procedures
-
Are charts and publications corrected up to latest notice to mariners received?<br>
-
Chart co is operational?<br>
-
ADP and ENC's where applicable are updated weekly?
-
Are other nautical publications, the latest editions and corrected up to date?
-
Is the compass error log maintained and up to date?<br>Deviation table posted and current, Compare recorded deviations with the posted table.
-
Watch and lookout arrangements in accordance with company guidelines?
-
Are latest navigational warnings, Navtex warnings, T& P notices and local area weather reports available on the bridge and endorsed on charts, if applicable?
-
Ae the Ship's Maneuvering characteristics, UKC policy, machinery failure procedures, Black Out procedures,, Table of Life saving signals displayed on the bridge?
-
Ate Auto/ Manual/ Emergency steering change- over procedures displayed?
-
Is passage planning conducted according to company requirements and berth to berth, including UKC Policy?
-
Is passage monitoring conducted in accordance with the company guidelines?
-
Are Pilot Information data sheets and relevant records in order?
-
Records of service and maintenance of Bridge/ Communication equipment
-
Records of Master's Navigational audits are available?
11. Communication Equipment
-
Main transmitting aerials are grounded, when engaged in cargo/ bunkering/ tank cleaning/ venting operations
-
AIS is operating on appropriate power?
-
List of Radio Signals are corrected and up to date
-
Emergency batteries are in good condition?
-
GMDSS logs maintained and daily / weekly tests recorded
-
Details of officer responsible for handling communications in an emergency updated?
12. Engine Room
-
Engine Room bilges are clean and free from oil and other materials.<br>
-
Last test of bilge alarm date:____________
-
Escape routes are clearly marked and EEBD's are located as per plan?
-
UMS Instructions are clearly posted?
-
Rotating machinery is suitably guarded and warnings posted?
-
Fire compartment boundaries maintained, Doors are NOT secured OPEN?
-
Appropriate PPE available in E/R, workshop and appropriate PPE worn by the crew?
-
Deadweight type and spring loaded sounding caps not permanently secured?
-
Hot surfaces adequately shielded and protected
-
All overboard valves effectively sealed and controlled as per Seal Log?
-
Procedures available to deal with emergencies?<br>1. Blackout<br>2. E/R flooding recovery<br>3. Dead ship start<br>
-
Controls in case of fire in E/R are clearly marked:<br>
-
Fixed fire extinguishing systemoperational? (specify Type)
-
Quick closing valves operational?
-
E/R ventilators and exhausts marked and operational?
-
Boilers, fans and burners in satisfactory condition?
13. Electrical systems
-
Records of tests of electrical equipment available?
-
Equipment in hazardous area is free from damage and bonding cables are in place?
-
Electrical Isolation permits are being used when required?
-
Records of test of batteries available?
-
Systematic testing o f fire detectors recorded?
-
Adequate insulation protection provided near switchboards?
-
E0 list and test records are up to date?
14. Steering Gear
-
Emergency change over procedure is displayed?
-
Rudder angle indicator is clearly visible at the emergency steering position?
-
Access is not obstructed?
-
Floor is slip proofed?
-
Gyro repeater is synchronized?
-
Two-way communication is available?
-
Test/ Drill records are available?
15. Emergency Generator
-
Starting/ operating instructions are clearly posted and understood by the crew
-
Regularly tested (Date of last test___________)
-
Starting/ Testing (including secondary means) procedures are available.
-
Ventilation dampers are clearly marked?
-
Fuel is maintained at adequate level?
16. Load Line Items
-
Visual inspection of the following items is satisfactory? (Deck Rounds)
-
Fuel and ballast tank vents
-
Hand Rails
-
Hull markings are Properly marked?
-
Hull markings are in accordance with the certificate?
-
Fore peak store and chain locker
-
Weathertight and watertight openings
-
Safety walkways are adequate
Critical Systems, Equipment and Spares
-
List of critical systems and critical equipment (identified) I maintained.
-
Maintenance of the above is clearly highlighted in PMS and being followed
-
Risk assessments are conducted prior 'shutting down' critical systems
-
Adequate critical spares are maintained on board for critical equipment
18. Other Compartments and Areas
-
General conditions of following compartments and areas are satisfactory
-
Paint Locker (FFA, Closed drums, MSDS available)
-
Hospital/ first aid kits, stretcher, resuscitation equipment).
-
No Expired Medicines
-
Crew accommodation, laundry, stores, public rooms, wash rooms clean
Galley
-
Clean and hygienic
-
No afire Hazards
-
Vent uptake mesh cleaned regularly and no oil deposits
-
Securing arrangements are proper?
-
FFA for galley operational, including fire blankets
-
No obvious slips/ trip hazards
-
Proper handling and disposal of waste
Fridge Rooms
-
Maintained at appropriate temperatures
-
Leakage test records available for refrigerants
-
PPE available and used?
-
Drains are clear with no build up of ice
-
Cold surfaces are adequately protected/ shielded
-
Storage is clean and secured
19. Security
-
Current security level displayed and known to crew?
-
Security arrangements as per security level effectively implemented?
-
Security records, gangway register adequately maintained?
-
Restricted areas marked and maintained as per plan?
-
Drills conducted as per plan and record of drills and participants maintained?
-
SSAS Tested (Last test date____________)
20. Planned Maintenance System
-
Is PMS software operational and job lists created for each month?
-
Are the spare part inventories updated in the PMS wrt. Critical spares
-
Checked the status of overdue jobs and CMS jobs.
-
Spot check carried out for verification of completed jobs?
21. Overall assessment (Ref Audit Report)
-
Are the ship's personnel aware of their duties and responsibilities?
-
Are adequate resources available to the ship's command?
-
Is the level of maintenance in accordance with company policy and guidelines?
-
Are any training needs identified during this audit?
-
Are any improvement areas identified during this audit?
-
Are the any health/ crew welfare issues identified during this audit?
-
Does the vessel management and cow appear sufficiently motivated and conversant with the company values?