1. General Information
-
Ship's Name:
-
Date of Inspection:
-
Place of Inspection
-
Operation:
-
Date of Last Inspection:
-
Have all the items from the last inspection been rectified?
-
Date of Last PSC Inspection:
-
Have all the deficiencies been rectified?
-
Date of Last Flag State Inspection:
-
Have all the deficiencies been rectified?
-
Date of Last Vetting Inspection:
-
Corrective actions in place for all the observations?
-
Date of Last Internal Audit:
-
Corrective actions in place for all the observations & N/C's ?
-
Date of Last Master's Review:
-
Company Response received and filed?
-
Date of last Class Status Report On board:
2. Certification & Documentation
-
Are the Ship's Certificates arranged and filed in accordance with SMM 7 App2?
-
Are the Ship's Certificates valid & Current?
-
Company Manuals (BDPM, CHM, ERPM, ECP, SOPEP/ SMPEP) in order?
-
Class Approved Manuals in Order (COW, ODMCS, Intact/ Damage Stability, IGS etc.)
-
Technical Manuals and drawings, User Manuals available?
-
ESP file & Attachments in Order?
3. Crew Management
-
Rest Hours Software working properly, regulations being observed and Deviations under Control?
-
Flag State Endorsements for all personnel in order?
-
Last D&A test by Concateno:
-
Last Random Alcohol test On board:
4. Navigation
-
Master's Standing Orders in place and acknowledged by all?
-
Deck log book maintained correctly? (Including records of safety & Fire rounds after watch while at sea?
-
Maneuvering characteristics posted on the Bridge?
-
Pre Arrival/ Departure checks completed and logged down correctly?
-
Under Keel and Air Draft Clearance policies well understood and forms duly completed?
-
Bridge Manning level being followed in accordance with BDPM 6.1.1 Attachment A & highlighted on the chart?
-
Bridge equipment is in good working order?
-
Compass error log book maintained correctly & errors being checked every watch?
-
Officers are aware of the procedures for VDR in the event of an accident?
-
Charts and Publications are corrected and up to date?
-
System in place to monitor the Navigational warnings and T&P notices?
-
ECDIS Operational and familiarization routines in order?
-
Position plotting frequency in accordance with BDPM 6.6?
-
Records of Echo Sounder usage available?
-
Berth to Berth passage plan available and following points correctly marked on the charts?
-
Parallel Indexing
-
Chart Changes
-
Method & Frequency of position fixing
-
Prominent navigation & radar marks
-
No Go Areas
-
Landfall targets and lights
-
Clearing lines & Bearings
-
Transit, Heading & Leading lines
-
Safe speed & necessary speed changes
-
Changes of machinery status
-
UKC
-
Use of echo sounder
-
Traffic density & cross traffic.
-
Anchor clearances
-
Contingency Plans
-
Abort positions
-
VTS & Reporting points
5. Safety Management
-
Safety Committee set up on board and regular Safety meetings held?
-
Evidence of crew participation
-
Safety meeting held on board by the Superintendent on board?
-
Are officers familiar with the operation of emergency equipment?
-
Is PPE on board adequate & used correctly?
-
SMART reports in line with the targets and follow up adequate?
-
Ship- Shore safety checklist in use and filled up correctly? (Including the repetitive checks)
-
Smoking regulations observed?
-
External doors & ports closed & the accommodation maintained at a slightly higher pressure?
-
Deck watch maintained and access controlled?
-
Timely familiarization of new personnel carried out?
-
Drills & Training being carried out regularly in accordance with ECP 7 App2?
-
Lifeboat & Rescue boat drills held regularly and none outstanding?
-
Restricted areas marked according to the SSP?
-
Security drills have been conducted & SSAS tested according to the plan (Include the last test date)
-
Enclosed space entry procedures are being followed correctly?
-
Pump room entry procedures being followed correctly?
-
Pump room flooding dampers clearly marked and in good working order?
-
Stretcher & Harness connected and ready for use in the pump room?
-
Gas sampling system for the ballast tanks, cofferdams and pump room is in use and correctly set?
-
Portable gas measuring instruments in order & calibration routines adhered to?
-
Sufficient supply of valid calibration gases & spare sensors available?
-
Officers familiar with the calibration procedures?
-
Hot Work procedures being followed correctly?
-
Welding equipment in good working order?
-
Oxygen & Acetylene bottles are stowed in separate compartments?
-
Flash arrestors are correctly fitted on the oxy- acetylene lines?
-
SOLAS lifesaving & fire training manuals in order?
-
Maintenance records of LSA & FFA are maintained correctly?
-
Muster lists/ Emergency instructions are updated including substitutes of key personnel?
-
Are lifeboats including their equipment & launching mechanisms in good working order (Davits, limit switches, falls, sheaves, winches & brakes)
-
Lifeboat & Life raft operating instructions displayed properly & located under the emergency lights?
-
Embarkation ladders are in good condition?
-
Lifeboat air support system in good order & test records available?
-
Life rafts in order and HRU's connected properly?
-
Lifebuoys/ ropes & lights in order? (Including Ex lights on deck)
-
Lifejackets & Immersion suits in order and service records available?
-
Test results for foam samples in place?
-
Isolation valves & hydrants on the foam & fire line are operational and maintained in good order?
-
Fire detection and alarm system in good working order?
-
Fixed fire fighting systems in good working order and records of periodic tests available?
-
Paint locker stowage in order & sprinkler system operational?
-
Portable extinguishers maintained correctly & records available?
-
Fireman's outfits in good order & maintained accordingly?
-
Water mist system is fully operational and in auto mode?
-
EEBD's in order, maintained accordingly and records available for periodic testing?
-
Fire flaps and accommodation ventilation emergency stops clearly marked?
-
MSDS for the current cargo displayed at a common location and everyone aware of the hazards?
-
Accommodation ladders, gangways & pilot ladders rigged correctly and maintained in good working order?
-
Safe access to the bow arrangements in order?
-
Helicopter/ winching area markings in order?
-
Following emergency equipment to be tested:
-
Emergency generator (Including alternative means of starting)
-
Emergency fire pump
-
Quick closing valves
-
Lifeboat Engines
-
Rescue boat engines
-
Reefer space alarm
-
Hospital alarm
6. Pollution prevention
-
Oil record books (Part 1&2) and cargo record books maintained/ completed correctly (Ref. MEPC.1/ Circ.736)
-
Sludge & bilge tanks mentioned in the ORB in accordance with the IOPP certificate?
-
Approved SOPEP/ SMPEP available & record of drills maintained?
-
VOCM plan available and records maintained? (If applicable)
-
Condition of scupper plugs is satisfactory and all scuppers are effectively plugged?
-
Bunkering & Fuel transfer:-
-
Piping diagrams are properly displayed?
-
Checklists are used prior bunkering & Internal transfer?
-
Spill containers and drip trays under the cargo/ bunker manifolds and save-alls under the fuel tank vents are clean, dry & effectively plugged?
-
Unused cargo & bunker manifolds are blanked & fully bolted?
-
Means are readily available to deal with small spills?
-
Is the vessel free of visible valve & pipeline leakages?
-
Sea and overboard valves are lashed/ locked/ blanked with adequate notices posted? (Including the forecastle area).
-
Testing arrangements for cargo sea chests in place & Operational?
-
Last annual test date of the bunker lines:________________
-
Last annual test date of the cargo lines & cargo hoses:__________________
-
Containment arrangement around the deck machinery is clean, dry & effectively plugged?
-
Pump room bilgr high level alarms operational?
-
ODMCS operational and records of tests available?
-
Emergency bilge pumping arrangements are ready for immediate use and adequate notices posted on the overboard valves?
-
OWS operational and records of use, tests & calibration available?
-
Adequate notices posted on the OWS overboard valves?
-
Operational test of 15 ppm alarm carried out?
-
Entries in the ORB for OWS discharges are in accordance with the requirements?
-
Storage & disposal of garbage according to the garbage management plan?
-
Garbage record book has been completed/ maintained correctly?
-
Exposed decks are free of oil/ residues/ garbage?
-
Bunker tank high level alarms operational?
-
Cargo tank high level& overfill alarms operational?
-
Is the Annex VI record book correctly maintained with records of fuel changeovers in ECA& use of ODS?
7. Structural Condition
-
Hull is free of visible structural defects?
-
Weather decks are free of structural defects?
-
Records available for inspection of the cargo& Ballast tanks and void spaces?
-
Inspection intervals are adhered to?
8. Cargo & Ballast Systems
-
Informaiton on Max loading rates& venting capacities is readily available in the CCR?
-
Up to date pipeline diagrams for Cargo, Inert gas & Venting systems are available in the CCR/ pump room as applicable?
-
Cargo pump performance curves available in the CCR?
-
Loading computer fully operational and test records maintained?
-
Has the cargo & Ballast handling plan been prepared in accordance with the CHM?
-
Emergency procedures agreed with the shore and all responsible personnel aware of the same?
-
Are all instrumentations/ automations in good working order?
-
Emergency shut downs for cargo pumps are operational and tested reguarly?
-
Are UTI´s in good operational condition and records of annual testing/ calibration available? (Including gas tight equipment if available)
-
Are remote temperature and pressure sensors operational and records of periodic tests/ calibration available?
-
Are alarm settings of the pressure sensors in accordance with the requirements?
-
Cargo heating system operational and records of tests available?
-
Is the vessel being operated under closed conditions and Mast risers/ PV valves set correctly?
-
PV valves & Mast risers are maintained properly (Including flame screens)?
-
IG valves are set correctly and keys are in control of the Chief Officer?
-
Maintenance/ Inspection records of the deck seal & NRV for the IG system are available?
-
Is the O2 content of the IG below 5% (As applicable)?
-
Calibration records for the fixed O2 analyser available and was this carried out just before the operation? (As applicable)
-
Liquid level in the Deck seal & PV breaker adequate?
-
COW plan available and all relevant checklists being followed? (As applicable)
-
REcords of operational test of COW lines before use?
-
Are static electricity precautions observed for vessels without IG?
-
Records available for the continuity tests for the cargo hoses & portable tank cleaning hoses? (As applicable)
-
Manifold gauges & thermometers in use and records available for routine calibrations?
-
Records available for the calibration of O2 sensors for the vapour return line?
-
Is the pump room clean, tidy & free of visible traces of oil& other debris/ combustible material?
-
Warning notices are posted?
-
Cargo cranes and other lifting equipment is is properly marked and records availabel for periodic testing/ inspections?
-
Chain register duly completed?
-
Cargo compatibility chart is available in the CCR? (As applicable)
-
Tank cleaning plans established and records available?
-
safety& protective equipment as required by the IBC code available and maintained properly?
-
Records available for the periodic testing of the above equipment?
-
Are the eye wash and decontamination showers fully operational? (WIth adequate pressure)
-
Cargo securing equipment maintained, marked & stowed properly? (PCC)
9. Mooring
-
Certificate available for all mooring ropes, wires, shackles & tails?
-
Each rope is tagged and and has an individually identified certificate?
-
Winch brake testing/ maintenance records available?
-
Are mooring ropes correctly reeled and secured properly?
-
SWL marking on equipment in order?
-
Bitter end securing arrangements are clear and the chain lockers are securely battened down?
-
ETA´s are readily available for deployment? (If applicable)
-
Condition of anchors& bow stoppers is satisfactory?
10. Communications
-
Main transmitting aerials are grounded when engaged in cargo/ bunkering/ tank cleaning & venting operations?
-
AIS is operating on appropriate power?
-
Emergency batteries are in good condition?
-
GMDSS logs maintained and daily/ weekly & monthly tests recorded?
-
Details of officer responsible for handling communications in an emergency updated?
-
Survival craft portable VHF radios & batteries in order?
-
UHF radios maintained in good condition?
11. Engine & Steering compartments
-
Chief Engineer´s standing orders in place and acknowledged by all?
-
Engine room log book completed and signed by all?
-
Quick closing valves are regularly tested and records available?
-
Emergency stops for Engine room ventilation are clearly marked & records available for periodic testing of the same?
-
Are fire dampers operational, tested periodically and closing peroperly?
-
Are diesel engine exhausts and other hot surfaces in the vicinity of fuel, diesel and lubricating & hydraulic oil pipes protected against spray?
-
Hot surfaces are adequately shielded & protected?
-
Is the lagging free of oil?
-
Purifier rooms are clean& tidy with no rags or other debris lying around?
-
Insulation mats are provided for all the electrical switchboards & are they in ecrtified for use and in good condition?
-
Gauge glass closing devices on oil tanks are not inhibited?
-
Deadweight type and spring loaded sounding caps not permenantly secured?
-
Rotating machinery is suitably guarded and warning signs posted?
-
Main & Auxiliary engines are free of oil, water & exhaust gas leakages?
-
Machine tools are provided with adequate eye protection?
-
Are machinery spaces and steering compartments clean and free from obvious leaks and is the overall standard of housekeeping and maintenance satisfactory?
-
Are bilges free of oil, debris and other residues?
-
Bilge high level alarms working and test records available?
-
Are seawater pumps, sea chests and associated pipework in good order and free of hard rust and temporary repairs. Particularly outboard of the ship side valves?
-
Instructions for starting the emergrncy generator are clearly displayed?
-
Sufficient fuel (18 hrs oeration) is maintained in the reserve fuel tanks?
-
Are the switchboards free of significant earth faults?
-
Escape routes are clearly marked, unobstructed and sufficient lighting provided?
-
EEBD´s in place according to the plans?
-
Fire compartment boundaries are maintained? (Doors are not secured in the open position)
-
Appropriate PPE available in the E/R& workshop?
-
Emergency steering has been tested and records available?
-
Emergency steering gear changeover procedures are clearly displayed in the steering compartment & wheelhouse?
-
Correct heading informaiton is available at the emergency steering position?
-
The floors have non-slip surfaces?
-
Communications with the bridge are satisfactory?
-
Overdue & CMS jobs in the PMS under control?
-
Spot check / verification of the completed jobs?
-
Electrical isolation permits are being used where required?
-
REcords of tests of batteries available?
-
Systematic testing of fire detectors is recorded?
-
General condition, visual appearance & cleanliness of the hull satisfactory?
-
Hull markings in order?
-
General condition, visual appearance & cleanliness of the weather decks is satisfactory?
-
Decks in working areas are covered with non-slip surfaces?
-
Condition of pipework on deck is satisfactory? (Check for significant corossion & pitting, soft patches & temporary repairs)
-
Watertight doors & portholes are well maintained and capable of being secured properly?
-
Are Fuel, ballast tanks and other space vents & air pipes in good condition and maintained properly? (Including the flame screens)
-
Lighting on deck is adequate?
-
EX rated light fittings in the gas hazardous areas are in good condition and maintained properly?
-
General inspection of store rooms indicate proper housekeeping?
-
Accommodation alleyways are free of obstructions and exits are clearly marked?
-
Proper housekeeping in the laundry?
-
Galley and pantry are clean& hygenic and maintained that way?
-
Refrigerated spaces are clean, tidy & there is no build up of ice on the lines/ drains?
-
Refrigerated spaces are maintained at correct temperatures?
-
Bulkhead penetrations in the accommodation are sealed properly to ensure integrity?
-
Hospital is neat & Tidy?