Information
-
Site conducted
-
Conducted on
-
Person Conducting Audit
-
Site Construction Manager
-
Address
-
State
-
comment
-
Photo of site
Site Information & Procedures
-
Is the correct signage visibly displayed and details completed (eg. Keep Out sign, Contractor requirements and Builders Site sign with lot number)?<br>
-
comments
-
Photos
-
Are external footpaths & entry access ways clean & free of hazards
-
Comments
-
Photos
-
Fences & Entry gates in good condition & secured
-
Comments
-
Photos
-
The following signs & facilities are easily identifiable
- Site Office
- Site Activity/Hazard Board
- Sign in Register
- Emergency Muster point
- First Aid Room
- Lunch Room
- Amenities Male & Female
- Parking
- Other
-
comments
-
The following documentation is easily accessible
- Contractor & Visitor Sign in Log
- Incident Register Log
- Safety Coordination plan
- OHS Policy
- Sustainability Policy
- Safety Alerts
- Emergency Response Plan
- Heritage Artifacts Poster
- SWMS Folder/Cabinet
- Specific Site Induction Log - (iAuditor Site Log)
- Toolbox Talks
- Electrical Test & Tag Log - Office
- On Site Plant Register
- First Aiders Photos& Contact Numbers
- If You are injured Poster
- Other
-
Comments
-
Are SWMS Site and job specific ie: <br>Irrelevant items crossed out and applicable items added and revised by site supervisor (signed & dated)
-
comments
-
Photos of sample SWMS
-
emergency response alarm/horn is easily accessible and functioning
-
comments
-
First Aid room/area clean, stocked, accessible
-
Comments
-
Photos
-
Potable water easily accessible
-
comments
-
Lunch Rooms
- Clean
- Food Prep area
- Bin with closable lid
- Fridge
- Kettle
- Microwave/Oven
- Cool Potable Water
- Hot water
- Heating/cooling
- Table & Chairs
- If U R injured poster
- PPE poster
- Safet Alerts
- OHS coordination plan
- Other
-
Comments
-
Comments
-
Photo
Environment & Sustainability
-
Is mud control ie. crushed rock/recycled mix/mulch, required on site, has an adequate amount been ordered or does it require a top up
-
Are the building spoils separated and into allocated piles. eg: timber, plaster, brick and blow away material in cage/bin
-
Is the site bin/cage/skip provided, accessible and not over flowing
- Yes
- No
- N/A
-
Is their adequate silt control on site eg: wash up pit, silt barrier, silt socks/sausages, brick barrier for sand
-
Noise is adequately managed on site to minimise impact to neighbours and ensure site comms eg: radios, start times, generators, plant equipment
-
Spill kit available and stocked
-
Photos
Site Conditions/Housekeeping
-
Crossover protection appropriately installed and maintained (if required)
-
Are the driveways, footpaths and nature strips clear of materials
-
Perimeter fencing appropriately installed and maintained (no missing panels/gates closed)
-
Slab back fill completed after slab construction (Level ground and stable)
-
Clear access to front door, toilet, power board & bin/cage
-
Is the site Trade ready (has the last trade completed all housekeeping so the next trade can complete their task internal & external
-
Is the toilet clean accessible and in correct operating condition with toilet paper
-
Comments
-
Photos
Working at Height (High Risk)
- Working @ Height
-
Area where fall hazard is being audited
- First floor and above edge protection
- Void areas
- Balcony internal
- Balcony external
- Stair void
- Stair run
- Roof zones
- Other
-
What type of fall protection is in place
-
What type of fall protection is in place
-
What type of fall protection is in place
-
What type of fall protection is in place
-
What type of fall protection is in place
-
What type of fall protection is in place
-
What type of fall protection is in place
-
Describe fall hazard
-
How is it managed
-
Will the work @ height endanger anyone working below
-
Comments
-
Photos
Trestles
-
External/internal, are they fully planked, less than 2m in height, have solid stable footings, safe access/egress and a clear fall zone, correct locking pins?
-
Are materials, equipment and personnel on trestles within their rated capacity? 225kg per bay
-
Photo - access/egress from trestles, work zone around trestles, not overloaded.
-
Comments
-
Photos
Ladders - (3 step ladders not allowed on site)
-
Access ladders in good condition, no damaged rungs, lean angle is not greater than 1:4 vertical ratio?
-
Access Ladders secure/tied off/when accessing heights ladders extend 900mm past step off point?
-
All types of ladders must be minimum industrial grade rated at a minimum 120kgs?
-
Step/platform ladder fully open, both stays in good condition and on stable ground
-
Are trades working off step ladders safely eg. not standing on top step and not over reaching to complete task (platform ladders recommended)
-
Comments
-
Photos
Void Protection (High Risk)
-
Void platform in place with compliance certificate (note the void protection is to be installed prior to installation of 1st floor walls and flooring)
-
Comments
-
Photos
-
Is the void trap door cover down whilst works occurring on 1st floor
-
Does the void protection provide safe access to upper level (configured correctly - minimise low clearance hazard
-
Comments
-
Photo
3 Plank Hang on Scaffolding (High Risk)
-
Is the scaffold certificate in place and signed off (eg. scaff tag)?
- Safety Chat
- Weekly Safety review
- Safety Alert
- Site Walk & Talk
- SWMS review
- Site Induction
- Contractor Meeting
- Developer Meeting
- SMS Alert
- Regulator Visit
- Other
-
Does the hanging bracket scaffold have safe access/egress, to work zones
-
eg both the work platform and roof area? (internal hop up at window/external hop up to platform/hop up to access roof
-
Are the mid rails, top rails and lap boards of the scaffold in place?
-
Does it feel secure and stable?
-
Are scaffold decks clear of debris?
-
Are all window voids protected after install
-
minimum 2 rails in height 450mm apart, structural timber must be used min MGP10 (merch is not to be used for temp rail)
-
Comments
-
Photos
Scaffolding (High Risk)
-
Scaff tag in date and signed off
-
Date last inspected
-
Clear access at ground floor to inside dwelling
-
Scaffold upright not leaning away from building structure
-
Top rail, mid rail and toe board fitted to all decks above 2m (2nd deck and higher)
-
Lap boards secured
-
Stair access to each level of the scaffold
-
No scaffold decks missing
-
No voids or fall zones in scaffold greater than 225mm between inner face of scaffold and external structure of building
-
Scaffold feels secure no excessive movement
-
Comments
-
Photo
Items of Plant & Trenches (High Risk Work)
-
Does the work require an operator with a licence/certificate of competency (Excavators, skid steer, forklift, crane, boom pumps, spotters, riggers...)<br>
-
Is there a pre-start checklist & SWMS completed for the item of mobile plant
-
Exclusion zones with spotter in place for all lifting tasks
-
Comments
-
Photo
Trades
-
A random check of trades on site - site induction completed (Check site induction log or Supervisor to scan Epass)
-
Are trades wearing appropriate PPE for tasks
-
Is machine guarding operational on required equipment
-
Comments
-
Photos
-
Are electrical leads Tested and Tagged, & within date
-
Comments
-
Photos
-
All mitre & drop saws have an extraction system in place
-
Nail guns are in single shot mode (unless flooring)
-
Outdoor trades working sun smart
-
Comments
-
Photo
Sign Off
-
Site Manager or Burbank representative