Information

  • Document No.

  • Contractor Name

  • Date and Time

  • Name of person completing this report

  • Location
  • OLT AREA (I.E SCN101)

General

  • Supervisor / Foreman at time of this inspection (if present)

Quality Audit

GENERIC AUDIT CHECKS (UG/OH/CIVILS)

  • Any cut cable ties (straps cable fixing) cut flush with no sharp edges. (CP10 S.3.5.4)

  • Any observed safety defects reported (A1024) (S.17)

  • Hazardous fibre waste (Sharps/Shards) cleared from site

  • Apparatus legibly labelled as per Reference Offer Spec (S.6, CP10 S.4)

  • Apparatus legibly labelled (Minor Defect) (S.6, CP10 S.4)

  • Cables routed through underground structure/on pole in a manner which will obstruct access to existing apparatus (CP8 s.21, CP10 s.3)

Overhead Specific Audit Checks

  • Apparatus fitted within correct envelope of space (CP8 s5, s.20)

  • Pole mounted apparatus securely fixed to the pole (CP8 s.5 s.21)

  • Upper Bass Step correctly repositioned and is compliant with step shift specification (CP17)

  • Are the plugs creosote inserted into the existing holes created by the removal of the coach screws (CP17)

  • Cables securely fixed at specified intervals and routed away from climbing steps, any coils managed in approved device. (CP8 s.3.4, s.20)

  • Cable(s) attached to pole top using spiral/wedge clamp (CP8 s3.1)

  • Use of aerial cable approved (CP8 s.2.2 & 2.3)

  • Newly provided OH cables compliant with minimum height requirements (CP8 s.9)

  • Any existing wires/cables below 5.2m reported (CP8 s.10, PD)

  • Newly provided OH cables, correct power separation distances maintained (CP8 s.12)

  • Pole capping replaced/provided where CP cables shares existing duct (CP8 s.3.4)

  • Overhead cable loadings not exceeded (DILOR) (CP8 s7)

Civils Specific Audit Checks

  • Internal duct seal correctly sealed to prevent ingress of water and gas following PIA cabling

  • No Excessive PIA cabling left within underground structure (CP10 s.6)

  • Cables correctly supported and restrained (CP10 s.3)

  • High security equipment/covers/locks replaced following cable/jointing work

  • Duct blockage correctly cleared (CP13 s.5)

  • Cables & equipment adequately protected for duration of works (CP13 s.6)

  • Cables & equipment free from damage attributable to work (CP13 s.6)

  • All materials & reinforcement compliant with specification (CP13 s.3, CN Drawing)

  • Joint box frame and cover compliant with specification ( CP13, CN drawing)

  • New joint box correctly sited in relation to poles and trafficked areas ( CP13 s.6)

  • Jointing chamber constructed as per specification (CP13, CN drawing, SAL spec)

  • Duct entry by approved method and finished correctly ( CP13 s.6.2, CN drawing, SAL spec)

  • Correct support and restraint of cables/joints disturbed by works ( CP13 s.6.1)

  • Duct entry in safe location (CP13 s.6 Retro/In)

General Comments

  • Any further comments or recommendations arising from this inspection?

  • Add relevant site photos (please include as many as possible)

Sign Off

  • Name of MS3 Supervisor

  • Name of Site Supervisor / Foreman (if present) of sub contractor

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.