  • Refer to procedures OP-200-373-003 BUL Substation Maintenance Manual before starting inspection.

Weather condition.

  • Wind Speed

  • Wind Direction

  • Outdoor Temperature (F)

Control House

  • Inside Temperature (F)

  • Control House Phone work?

  • Lights

Bull Hill Net output (From One Line P1)

  • MVAR

  • MW

115KV /35.5KV Metering (KT1H Control on HMI)

  • Add media

Fire Detection, Extinguisher

  • Alarms Ok?

  • Extinguishers Charged?

  • Inspection Tag Up to date?

Tesla DFR 4000

  • Visible Light Check

Relays

  • Any Alarms

Automatic Xfer Switch

  • General Condition

  • Connected To

Emergence Battery Rank Charger

  • Float Charge Voltage (VDC and ADC)

  • Alarms

Emergence Battery Bank

  • Voltage Reading (VDC)

  • Temperature (F)

  • General Appearance (Cleanliness)

  • Electrolyte Levels

  • Evidence of Leaking

Substation Yard

  • Fencers Perimeter.( Equipment and Grounds)

  • Lights

Xfmer, Station Service

  • Oil Leak

  • General Condition

  • High and Low Voltage Buishings

  • Lighting Arrestor

Circuit Breakers, Switch

KT1H E1

  • General Condition

  • Disconnect Switches Fully closed/Latched

KT1H

  • Open/Closed

  • Counter Reading

  • SF6 pressure (PSIG)

  • General Condition

  • Cabinet Moisture

  • Heaters

  • Spring Mechanism

BHW1

  • Open/Closed

  • Counter Reading

  • General Condition

  • Cabinet Moisture

  • Heaters

  • Disconnect Switches Fully closed/Latched

BHW2

  • Open/Closed

  • Counter Reading

  • General Condition

  • Cabinet Moisture

  • Heaters

  • Disconnect Switches Fully closed/Latched

BHW1-E1

  • Disconnect Switches Fully closed/Latched

BHW1-E2

  • Disconnect Switches Fully closed/Latched

BHW2-E2

  • Disconnect Switches Fully closed/Latched

BHW2-E1

  • Disconnect Switches Fully closed/Latched

Buses 34.5KV

  • General Condition

Lighting Arrestor

  • General Condition

3-PT's

  • General Condition

Main Power Transformer

  • Evidence of Leaking

  • Oil Level (degrees)

  • General Condition( Bushings, Tank, Radiators)

115KV Bushings

  • Oil level

34.5KV Bushings

  • Oil level

Cooling

  • Cooling Fan operational

  • Oil Temperature (C)

  • Oil Temperature (C) Max

  • Winding Temperature (C)

  • Winding Temperature (C) Max

Nitrogen Cabinet

  • Bottle Presser (Psi)

  • General Condition

Lighting Arresters

  • General Condition

Main Control Cabinet

  • General Condition

  • Breaker Status

  • Cabinet Moisture

Automatic Tap Changer

  • General Condition

  • Oil Level (degrees)

  • Counter Reading

  • Tap Position

  • Tap Max

  • Reset followers

ATC Filter Cabinet

  • General Condition

  • Run Time (Hours)

  • Evidence of Leaking

Emergency Generator

  • Block Heater Running

  • General Condition

  • Run Time (Hours)

  • Battery Reading (VDC)

  • Alarms

  • Oil Level

Notes

  • Add Notes

  • Inspectors

  • O&M Manager's

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.