Information

  • Audit Title

  • Document No.

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

  • Select date

  • Add location
  • Area of inspection

  • Photos

  • Drawing list

  • Completion

Inspection of Structural Steel

  • Do base plates align properly with concrete?

  • Erected steel is aligned and plumb in accordance with CSA S 16.1

  • Have all connections been properly made and fully bolted according to plans and specifications?

  • Are required braces bolted and properly installed?

  • High strength bolts in place and torqued as required.

  • Structural bolts are correct type and length (spot check)

  • Bolts tightened (indicated by the burnishing or preening of the corners by the impact wrench)

  • Beveled washers installed where specified

  • Framework laid across the opening at the right place and right size (see Roof Plan)

  • Is structural steel primer clean, with shop coat in good condition and any erection marks burn and/or scratches repainted?

  • Third party inspection performed for this inspection

  • Additional Notes

  • Pictures pertaining to Structural Steel Inpection

Inspection of Steel Joists and Girders

  • Joists and Joist Girders properly made up and aligned

  • Bridging location and attachment conforming to IFC Joist drawing

  • Panel supports (SP) installed and attached (welded or bolted) as per plan

  • Joists have all shoes bolted

  • Joists have all shoes welded (where indicated on drawing)

  • Special material welded (transfer plates etc)

  • Third party inspection performed for this inspection

  • Additional Notes

  • Pictures pertaining to Steel Joist & Girder Inspection

Inspection of Steel Deck

  • No apparent deformation of steel deck

  • Nailed pattern fixation conforming to specified decking Notes on IFC drawings

  • Have the right nails been used?

  • Welding pattern fixation conforming to specified decking Notes on IFC drawings

  • Has the welds been correctly performed?

  • Sidelap screws fixation conforming to specified decking Notes on IFC drawing

  • Welded perimeter angle installed per IFC drawings

  • Continuity angle below perimeter angle welded as per IFC drawing

  • Galvanized piece (AZ) placed over the panels to cover the siding

  • Deck opening cut at the roof (if applicable)

  • Third party inspection performed for this inspection

  • Additional Notes

  • Pictures pertaining to Inspection of Metal Deck

Inspection of Murox® Panels

  • Interior panel joint: Continuous seal and compliance with Murox® Installation Manual and Flashing Plan

  • Exterior panel joint: Continuous seal and compliance with Murox® Installation Manual and Flashing Plan

  • Interior panel corner: Continuous seal and compliance with Murox® Installation Manual and Flashing Plan

  • Exterior panel corner: Continuous seal and compliance with Murox® Installation Manual and Flashing Plan

  • Overall details in compliance with Murox® Installation Manual and Flashing Plan

  • Personnel Doors: Functionality and hardware as per project specification

  • Shop installed Windows: Any visual defects

  • Sealing of roofing vapor barrier at the head of the Murox® panels conforming to Murox® recommendation

Inspection of Interior Siding

  • Location of defects of siding

  • Pictures of defects

Inspection of Exterior Siding

  • Location of defects of siding

  • Pictures of defects

Signatures

  • CANAM Representative

  • General Contractor/Owner Representative

  • CANAM Project Manager

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.