Title Page
-
Customer Name
-
Conducted on
-
Location
Customer info
Customer info and Signatures
-
Customer Mrn
-
Job card Number
-
Customer Signature
-
Technician Signature
Aboveground tanks
Aboveground Tank
-
Is there on the external tank shell corrosion and paint failure?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Is there on the tank ladder ,platform and handrails corrosion or paint failure?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Tank platform safe to enable operators to conduct tank gauging ?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Any corrosion or leakage on flanges and nozzles?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Manholes and bolts secured in place?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Valves in normal operation and no leakage?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Tank vent free off any blockage?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Tank checked for water by using water finding paste?
-
Water draw off valve in normal operation and residue water drained off?
-
Is dip cap assembly still sealing?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Replace Seal immediately......
-
Tank level gauge in normal operation?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Tank steel saddles not corroded and holding down bolts are secured in foundation?
-
Attention required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Tank bonded to an earth conductor?
-
Attention required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
Pipelines
-
Denso wrapping along pipeline in good condition?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Replace Denso wrapping
-
Pipeline and associated fittings leaking?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Any surface corrosion,pitting or paint failure on pipeline?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Pressure test underground pipeline with Nitrogen to 500 kpa,
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Pipeline checked according to API 570 standard?
-
Ultrasonic thickness test result?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
Tank bund walls and foundation
-
Any spalling,settlement and cavities in tank foundation?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Any structural damage and cracks in bund wall and floor?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Rubble and combustible material inside bundwall?
-
Bund outlet valve close/locked and in good condition?
Meter Box and Fittings
-
Meter box lockable?
-
No corrosion or paint failure off meter box?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Hose securely rolled onto hose reel?
-
Any signs off sweating,pinhole leaks,circumferential bulges,deep exterior cuts,abrasions breakage or collapse on hose?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Take hose out of service and replace with new hose.....
-
Nozzle and clamps leaking and in normal operation?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Any leaks on pipe fittings or meters?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
Transfer Pump
-
Pump and motor securely mounted to pump base?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
-
Coupling guard fitted and secured?
-
Any leaks on seals?
-
Attention Required
- Routine Item
- Safety Item
- Environmental Item
- Critical Item
- Investigation Item
- Carryover From Previous Inspection
Safety
-
Fire extinguishers available at meter box area?
-
Record last inspection date
-
Any emergency spill containment available?
-
Engen emergency contact number(0800036436) available?