Information

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

1.0 - Screws To Walls / Ceilings

  • 1.1 - Boards Screwed @ 300mm Centres

  • 1.2 - Door Perimeter Screwed Up @ 200mm Centers

  • 1.3 - External / Internal Corners Screwed @ 200mm Centres

  • 1.4 - Ceiling Boards Screwed @ 250mm Centre's Minimum Of 5 Screws

  • 1.5 - Ceiling Board Ends Screwed @ 150mm Centre's

2.0 - Insulation

  • 2.1 - Correct Thickness Of Insulation Installed And Secured In Place Correctly

  • 2.2 - No Visable Gaps In Voids

3.0 - Boards

  • 3.1 - Boards @ Correct Deflection From Soffit

  • 3.2 - Door Edges / Reveals External Corners Surfed Back

  • 3.3 - Correct Type Of Boards Used In Locations

4.0 - Flat Plate

  • 4.1 - Flat Plate Fitted @ Correct Height

  • 4.2 - Flat Plate Tek screwed To Studs correctly

  • 4.3 - Flat Plate Screwed Between Board Centre

  • 4.4 - No Joins Between Studs

5.0 - Mastic Seals

  • 5.1 - Service Penetrations Sealed With Correct Mastic / Board

  • 5.2 - Board Joins Sealed Within Ceiling Void / Tape & Jointed Or Fire Mastic To Specification

  • 5.3 - Corners Sealed Mastic Correctly

6.0 - VCL

  • 6.1 - Correct Gauge Of Polythene Used And Overlapped By 100mm And Tapped

  • 6.2 - Joins To Poly Overlapped Minimum 100mm And Taped

  • 6.3 - Window Opening Overlapped By 100mm And Taped

7.0 - MF Ceilings

  • 7.1 - Hangers Spaced @ No More Than 1200 / Main Bar MF7 Installed @ No More Than 1200 / 6A Screwed To Board/FlatPlate Studs

  • 7.2 - Ceiling Installed @ Correct RCP Height In Each Room

  • 7.3 - MF7 & MF5 Set Out To Avoid Light Clashes

8.0 - Cables / Services

  • 8.1 - Cables Pulled At M&E Marked Heights

9.0 - Noggins

  • 9.1 - Kitchen Noggins Installed Correctly @ Correct Height And Angle Added

  • 9.2 - Bathroom / Ensuite Noggins Installed Correctly With Angle Added

10.0 - Window Reveals

  • 10.1 - Equal Margin Achieved Around Entire Window

  • 10.2 - Reveals Plumb / Square

11.0 - Wet Rooms

  • 11.1 - Ply Fitted With Expansion Gaps 10mm

  • 11.2 - Wedi / Dukka / Tile Backer Fitted And Screwed Correctly

  • Add signature

  • Select date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.