Title Page
-
Prepared by
-
Date:
Lift Inspection
Lift Identification
-
Lift Model #:
-
Lift Serial #:
-
Record rated load capacity of lift:
- 7,000
- 9,000
- 10,000
- 12,000
- 15,000
- 18,000
- 30,000
- Other:
- N/A
-
Rated Load Capacity:
-
Lift Type:
-
Surface Lift Type:
- 2-Post
- 4-Post
- #-Post
- Scissor
- Low/Mid-Rise
- Wheels Free Device
- Mobile Column
-
Number of Posts:
-
Number of Units:
-
In-Ground Lift Type:
-
Identify Pressure Design:
-
Identify Pressure Design:
-
Identify Pressure Design:
Inspection Points - All Lifts - Apendix C, ALOIM:2008(R2013)
-
Check accessibility, confirm readability & appropriate lift safety labeling or placarding, report deficiencies (ALOIM 5.6.2.4)
- ALI/WL 101, for two post surface mounted lifts
- ALI/WL 200 for surface mounted wheel engaging lifts
- ALI/WL 300, for hinged frame engaging lifts
- ALI/WL 400 for wheel engaging mobile units
- ALI/WL 500, for inground lifts
- ALI/WL 600, for single post lifts
- No Label
-
Check with operator to ascertain any unusual operating characteristics such as lift raises overnight or not lifting load capacity. (ALOIM 5.6.3.4)
-
Confirm adequate clearances around lift to accommodate anticipated service activities and emergency egress, report deficiencies. (ALOIM 5.6.2.7)
-
Examine all accessible structural components including welds and report any evidence of overloading, misuse, abuse, permanent deformation on cracks. (ALOIM 5.6.2.8)
-
Examine electrical components, wiring & confirm appropriate electrical component labeling (ALOIM 5.6.2.9)
-
Check lift controls to ensure accessibility, unobstructed view of the lift & verify automatic return to neutral, or off, when released (ALOIM 5.6.2.10)
-
Check anchor bolts (if employed) in accordance with recommendations of anchor bolt & lift manufacturer
-
Check all fastening devices for tightness, report deficiencies. (ALOIM 5.6.2.14)
-
Check all points requiring lubrication (Use manufacture guidelines whenever possible) (ALOIM 5.6.2.19)
-
On lifts requiring swing arm restraints, report improper function and/or excessive wear or damage (ALOIM 5.6.2.13)
-
Check all swivel pins for excessive wear, elongation or hole deformation.
-
Operate the lift & check the operation of the positive stop & lift locks, report improper function, excessive wear or damage. (ALOIM 5.6.2.16)
-
Inspect all chains & wire ropes, report excessive slack (use manufacture guidelines whenever possible). (ALOIM 5.6.2.23)
-
On lifts equipped with lateral synchronization or equalization systems, check the operation of these systems by running the lift through its full excursion. (ALOIM 5.6.2.20)
-
Check the tracking & level winding of wire ropes & chains, report deficiencies. (ALOIM 5.6.2.24)
-
On lifts incorporating overhead structures, verify the safety shut-off functions properly. (ALOIM 5.6.2.22)
-
Check all potential pinch points & report those that are unprotected by appropriate guards or instructions. (ALOIM 5.6.2.25)
-
Check all accessories for construction, labeling (including capacity) & certification for use with the specific lift. (ALOIM 5.6.2.28)
Additional Questions - In-Ground Lifts, Lube Racks & WEMU Units - Appendix C, ALOIM:2008(R2013)
-
Report water in sub-floor pits or enclosures. (5.6.2.27)
-
On lifts incorporating working platforms, railings & stairways, report any deficiencies (ALOIM 5.6.2.21)
-
For multiple powered posts, confirm single point operation from only one position at a time, report deficiencies. (ALOIM 5.6.2.26)
-
On mobile wheel engaging lifts, check the mobility of each individual unit & confirm each unit cannot be moved when loaded. (ALOIM 5.6.4.5)
Hydraulic Lifts & Hydraulically Driven Mechanical Lifts - Appendix D, ALOIM:2008(R2013)
-
Is lift a Hydraulic Lifts or Hydraulically Driven Mechanical Lift?
-
Skip This Section
-
Record Oil Type:
-
Other:
-
Check all accessible piping, tubing, hose, valves & fittings and review the oil consumption records. (ALOIM 5.6.3.1)
-
Check cylinder(s) for cracks and leaks
-
Check hydraulic and air hoses for leaks
-
Verify presence of hydraulic relief valve & check integrity of tamper resistant seal, report broken seal or evidence of tampering. (ALOIM 5.6.3.10)
-
On lifts utilizing pumping units, confirm adequacy of oil level at fully raised position, report cavitation, oil foaming, or oil contamination. (ALOIM 5.6.3.9)
-
Is lift a 4-Post Lift? (ALOIM 5.6.2.11)
-
Skip This Section
-
Check presence & proper operation of fixed/automatic runway stops & accessibility of wheel chocks.
-
Check turntables and/or slip plates for ease of movement. Report deficiencies.
-
Check the integrity of the anti-slip surface surface treatment.
Pneumatic lifts - Appendix F, ALOIM:2008(R2013)
-
Is lift a Pneumatic Lift?
-
Skip This Section
-
Check all accessible piping, tubing, cylinders, air bags, hoses, valves, fittings, and report any leaks. (ALOIM 5.6.6.1)
-
Check with operator to ascertain any unusual operating characteristics such as lift raises overnight or not lifting load capacity. (ALOIM 5.6.6.3)
-
Confirm presence of pressure regulator in supply line, report deficiencies. (ALOIM 5.6.6.4)
-
Inspect cylinders, air bag or bellows for damage. (ALOIM 5.6.6.5)