1. Drilling Location
-
Authorized Personnel Sign Posted 1910.145(c)(2)(i) RP54 7.1.2-3<br>
-
Hard Hat/Safety Glasses Signs Posted 1910.145(c)(3)
-
No Smoking Area’s Designated & Posted RP54 7.1.2-3 1910.145(c)(2)(i)<br> <br>
-
No Parking within 100 ft of the rig RP54 6.1.15
-
H2S warning signs erected, if applicable 1910.145(c)(2)(i) 1910.1000(e) 1910.1200(f)(5-6) RP54 7.1.2-3<br><br>
-
Emergency escape air packs and life lines available, if applicable 1910.134(d)(2)(i) RP55 3.3 RP55 3.9<br><br>
-
Escape & Guy wires flagged RP4G 7.6.f
-
Outhouse/restroom facility provided or in close proximity to the site. (LT 10 min travel time or 2 miles, whichever is less) (Facility in close proximity only applies if the site is active for less than 1 day) 1910.141(c)(1)(i)<br>
-
Outhouse clean and sanitary, if provided. 1910.142(d)(10)<br>
-
Hard hats & Safety glasses available for visitors 1910.132(a<br>
-
Toolpusher’s trailer grounded RP54 6.1.16<br>
-
Toolpusher’s trailer securely positioned RP54 6.1.16<br>
-
Housekeeping looks good? 1910.22(a)(1) RP54 6.5.1<br><br>
-
Distance from overhead powerlines GT 10 ft RP54 10.1.1
-
Toolpusher at rig location
-
Muster area designated & posted 1910,38(c)(4
-
Visitor tracking system in place I.E. a sign in box. 1910.38(c)(4)
-
All vessels labeled as to their contents 1910.1200(f)(4-5)
-
Supply storage house clean 1910.22(a)(1) RP54 6.5.1<br>
-
Crew change house clean 1910.22(a)(1) RP54 6.5.1<br>
-
Wind Sock available. (H2S may be present) RP55 4.5
-
Evacuation/All-clear alarms system in place? 1910.38(d)
2. TRAINING, PPE & GENERAL SAFETY
-
Someone has First Aid Training RP54 4.3.
-
Certification Card(s) available RP54 4.3.1
-
Pre-Job safety meetings conducted before each shift or if new hazards happen. RP54 6.1.7
-
OSHA poster posted 1903.2(a)(1)
-
Proper clothing worn by crew (No loose clothing). FRC RP54 5.2.5 RP54 5.2.6 1910.132(a)<br>
-
Hard hats used by crew RP54 5.2.1 1910.135(a)(1-2)<br>
-
Safety glasses used by crew RP54 5.2.2 1910.133(a)(1-5<br>
-
Steel toed shoes used by crew RP54 5.2.3 1910.136(a)<br>
-
Hazardous jewelry not worn by crew RP54 5.2.7 1910.132(a)<br>
-
Fall protection used, when required RP54 5.5.
-
No Smoking rules observed only in approved areas RP54 7.1.3
-
First Aid Kit/Bloodborne Pathogen Kit available on site 1910.151(b) RP54 4.3.2<br>
-
Emergency phone numbers posted RP54 4.2.1 RP55 4.6<br>
-
MSDS’s available and accessible RP54 6.1.12 1910.1200(g)(1)<br>
-
Emergency response plan from the rig available 1910.38(b) RP55 4.1-10<br>
-
BOP training up to date RP54 6.4.4
-
Written safety program available from each contractor RP54 6.1.7
-
Hearing protection required in posted areas RP54 5.3.1-2 1910.95(a)<br>
-
Long Hair contained RP54 5.2.8
3A. MUD PUMP AREA
-
Drive belts guarded RP54 6.8.2-3
-
Pony rods guarded RP54 6.8.2-3
-
Shear pin pop-off valve present and covered 1910.169(b)(3)(i-iv)
-
Pressure relief valves present 1910.169(b)(3)(i-iv)
-
General housekeeping of the area RP54 6.5.1 1910.22(a)(1)<br>
-
Discharge lines from relief valves are anchored
3B. MUD MIXING AREA
-
Adequate personal protective equipment available. Rubber gloves, Face shield, Apron, Respirator, etc PER MSDS RP54 6.13.2 1910.132(a)<br>
-
Personal protective equipment properly stored and clean RP54 6.13.2 1910.132(a)<br>
-
Eye wash station available in close proximity and in working order 1910.151(c) <br>
-
Eye wash station in a clean & sanitary condition 1910.141(d)(1)
-
Eye wash station providing clean water supply 1910.141(b)(1)(i)
-
General housekeeping RP54 6.5.1 1910.22(a)(1)<br>
-
Adequate lighting provided
3C. MUD TANKS & PITS
-
Adequate stairs with handrails 1910.24(h) 1910.23(d)(1)<br>
-
Adequate walkways and guardrails 1910.23(c)(1
-
Guardrails installed on all raised platforms, walkways, etc above 48” 1910.23(c)(1) 1910.23(d)(1<br>
-
Walkways free from obstruction and/or damage 1910.23(c)(1
-
Guardrails provided on crossovers 1910.23(c)(1)
-
Shale shaker properly guarded 1910.23(c)(3
-
Explosion proof equipment used in the vicinity of the shale shaker 1910.307(b)(1-3) & subsections 1910.307(c) <br>
-
Agitator shafts & couplings properly guarded 1910.212(a)(1)
-
Mud guns properly secured RP54 9.11.2
-
Jetting hoses properly secured RP54 9.11.2
-
Approved lighting for the location installed 1910.307(b)(1)
-
Stairways and ladders secured RP54 9.3.8
-
General Housekeeping 1910.22(a)(1) RP54 6.5.1<br>
-
All unused floor holes covered 1910.23(a)(8) 1910.23(a)(9<br>
-
Electric wiring in good condition 1910.303(b)(1-2) 1910.303(c)<br>
4. GENERATOR AREA
-
Generators properly located in safe area RP54 9.14.2
-
Moving parts guarded 1910.212(a)(1
-
Generators properly grounded RP54 9.14.11
-
Cover panels on electrical control boxes installed and closed. 1910.305(b)(2)
-
All electrical controls marked as to their function and legible. 1910.303(f
-
HIGH VOLTAGE” warning signs erected 1910.145(c)(2)(i) 1910.305(b)(2)(ii<br>
-
Insulating mats available at electrical panels 1910.335(a)(2)(ii)
-
All electrical tools grounded 1910.304(f)(5)(v)
-
Condition of electrical wiring 1910.303(b)(1-2
-
Electrical wires properly strung 1910.305(a)(2)(iii) RP54 10.2.3<br>
-
Unused electrical outlets covered 1910.305(b)(1-3)
-
Air compressors properly guarded 1910.212(a)(1
-
Air storage tanks equipped with pop-off valve 1910.169(b)(3)(i-iv)
-
Lockout/Tagout devices available RP54 6.9.1 RP54 9.14.9<br>
-
Hearing Protection Required” warning signs erected. 1910.95(b)(1
-
Hearing protection available 1910.95(a)
-
Adequate lighting installed RP54 9.14.7 1910.303(h)(3)(ii)<br>
-
General Housekeeping RP54 6.5.1
-
Equipment properly classified for the location RP54 9.14.6 RP54 10.2.1 RP500 4.1-5 RP500 5.1-2<br>
-
Electrical wiring/fixtures/etc approved for the location (Cl 1 Div 1 or 2 location) RP54 10.2.1 1910.307(b)(1-2)<br>
-
Wires not running along the ground RP54 10.2.3 1910.305(a)(1)(iii)(G)<br>
-
Receptacles and plugs in good condition 1910.303(b)(1)
-
Fire extinguishers rated for electrical fires 1910.157(d)(1)
5. FIRE PROTECTION
-
B/C class fire extinguishers available RP54 7.2.4 RP54 7.2.5<br>
-
Adequate number of fire extinguishers available 1910.157(d)(2-6) RP54 7.2.4 RP54 7.2.5<br>
-
Fire extinguishers properly charged 1910.157(c)(4)
-
Fire extinguishers properly located 1910.157(c)(1) RP54 6.5.5 RP54 7.2.2 RP54 12.1.3<br>
-
-
Flammables stored in UL listed safety cans 1910.106(d)(2) RP54 8.1.1<br>
-
No Smoking rules enforced RP54 7.1.2-6
-
Spark and heat arrester, or water, on all engine exhausts RP54 9.15.3
-
Welding work performed safely RP54 7.2.6
-
All engines located approx 100 ft from the well or gas source, if possible RP54 9.14.2 RP54 9.15.3<br>
-
Fire extinguishers tagged and/or inspection data logged into database 1910.157(e)(1) RP54 7.2.3 RP54 7.2.7<br>
-
Fire extinguisher location easily identified 1910.157(c)(1) RP54 6.5.5 RP54 7.2.2<br>
6. FUEL STORAGE TANKS
-
Fuel storage tanks properly located RP54 8.3.5 1910.106(b)<br>
-
All storage valve connections identified as to their function 1910.106(b)
-
Discharge nozzles in good condition 1910.106(b)
-
Discharge hoses in good condition 1910.106(b
-
Discharge valves in good condition 1910.106(b)
-
Piping and fuel lines in good condition 1910.106(b)
-
Stationary ladders on storage tanks in good condition 1910.27(f)
-
Approved lighting for the location installed 1910.307(b)(1)
-
Fuel tanks properly labeled RP54 8.4.1d 1910.1200(f)(4-5<br>
-
“Flammable” warning signs erected 1910.145(c)(2)(i) 1910.1200(f)(5-6) RP54 7.1.2-6 RP54 8.4.1d<br>
-
“No Smoking” signs erected 1910.145(c)(2)(i) 1910.1200(f)(5-6) RP54 7.1.2-6 RP54 8.4.1d<br>
-
No Open Flame” signs erected RP54 7.1.2-6 1910.145(c)(2)(i) RP54 8.4.1d<br>
-
Vapor release vents elevated & away from ignition sources 1910.106(b
-
General housekeeping RP54 6.5.1 1910.22(a)(1)<br>
-
Grass & debris kept away from area RP54 6.5.1
-
B/C Class fire extinguisher available RP54 8.4.1e 1910.157(c)(1) 1910.157(d)(1)<br>
-
Protective caps on all fuel cylinders RP54 8.3.3
7. PIPE RACK AREA
-
Ends of pipe racks properly chocked 1910.176(b) RP54 9.12.3<br>
-
Spacers used to separate layers of pipe 1910.176(b)
-
Layers of pipe properly chocked 1910.176(b) RP54 9.12.3<br>
-
Stairs with handrails provided 1910.25(h)
-
Derrick stand and ladder in good condition 1910.27
-
Dead end of drilling line anchored RP9B 3.3.9
-
Approved lighting installed 1910.307(b)(1)
-
General housekeeping 1910.176(c) RP54 6.5.1<br>
8. BLOW-OUT PREVENTERS
-
BOP properly installed RP54 6.4.1
-
BOP properly tested RP54 6.4.1 RP54 6.4.13<br>
-
BOP stack properly stabilized RP54 6.4.10
-
All hydraulic lines connected RP54 6.4.18
-
All unused hydraulic lines capped and secured RP54 6.4.18
-
Accumulator unit properly located
-
Accumulator valves in appropriate position, open or closed and secured
-
Gauges properly located
-
Choke manifold and line secured RP54 6.4.18
-
Approved lighting for the location installed 1910.307(b)(1)
-
Warning signs erected 1910.145(c)(2)(i) RP54 7.1.2-3<br>
-
Proper drainage provided RP54 6.5.2
-
General housekeeping RP54 6.5.1 1910.22(a)(1)<br>
-
Safety valve and handle for tubing installed RP54 6.4.2
-
Hydraulic lines protected
-
BOP Control Lines & Valves identified RP54 6.4.11
-
Daily inspections of the BOP’s conducted RP54 6.4.7
9. DERRICK & SUBSTRUCTURE
-
Derrick/A-Frame assembly pins in place RP54 9.2.8
-
Assembly pins secured with keepers RP54 9.2.8
-
Number of wind guys RP4G 6.1-8RP54 9.2.10<br>
-
Condition of guy lines RP4G 5.1.c
-
Diameter of guy lines RP9B 3.7.4
-
3 clamp minimum, 4 clamp minimum with sheave RP9B 3.7.4
-
Clamps properly attached RP9B 3.7.4
-
Ground anchors RP4G 7.1-8
-
Anchor pull test performed RP4G 7.1-8
-
Anchors positioned IAW rig manufacturer’s specifications RP4G 7.1-8
-
TUBING BOARD GUYS
-
Strung and crossed for racking
-
3 clamp minimum RP9B 3.7.4
-
Clamps properly attached RP9B 3.7.4
-
Fall lane of derrick clear
-
Vehicles out of guy pattern
-
Manufacturer’s specification/operation plate attached to derrick RP54 9.2.2
-
Damage and/or corrosion to derrick (waste metal) RP54 9.16.1
-
Damage and/or corrosion to substructure (waste metal) RP54 9.16.1
-
Condition of derrick ladder RP54 9.3.1-2
-
Climb assist device available 1910.27(d)(5)
-
Climb assist device used by derrickman. and in good condition
-
Full body harness with lanyard available 1910.132(c)(1) RP54 5.5.1<br>
-
Fall protection devices in use RP54 5.5.1
-
Derrick/Tubing boards in good condition RP54 9.2.17<br>
-
Guardrails installed on derrick board RP54 9.3.17 RP54 5.5.1<br>
-
Pipe fingers in good condition RP54 9.2.17
-
Derrick board walk around platform in good condition, if available
-
Finger board in good condition RP54 9.2.17 RP54 9.3.16<br>
-
Crown guardrails installed RP54 9.3.17 1910.23(c)(1)<br>
-
Scoping ram stabilizers in good condition RP54 9.2.4
-
Crown sheave guards in place RP54 9.7.5
-
Cracks, metal fatigue or wear evident at hinge points RP54 9.2.4
-
Safety retainers in use on hinge pins RP54 9.2.8
-
Derrick locking pins in place with safety pins RP54 9.2.8
-
Dead line properly anchored RP54 9.6.5 RP9B 3.3.9<br>
-
Approved lighting for the location installed 1910.307(b)(1)
-
Derrick emergency escape line installed RP54 6.10.1
-
Geronimo on-line and ready for immediate access and use. RP54 6.10.1
-
Emergency escape line adequately anchored, per manufacturers specifications, in a clear area away from the rig. RP54 6.10.1
-
Tools secured at elevated levels RP54 9.2.13
-
Mud standpipe/hose secured
-
Data plates installed on derrick that provide information on guying, derrick, etc inst
10. DRILL FLOOR AREA
-
Kelly bushing guard used RP54 9.8.3
-
Controls adequate if guard not used RP54 9.8.3
-
Rotary chain drive guarded 1910.212(a)(1-3)
-
All unused floor holes covered 1910.23(a)(8-9) RP54 9.1.1 RP54 9.3.20 RP54 9.3.21<br>
-
Driller at or near controls RP54 9.4.4
-
Drillers controls properly labeled/identified
-
Pipe slips & Dies in good condition RP54 9.9.2
-
V-door gate provided and in place 1910.23(c)(1)
-
Air hoist line in good condition RP9B 3.2.7
-
Air hoist line properly layed RP9B 3.3.3
-
Cathead line divider/grip in good condition RP54 9.5.1
-
Catline not worn or kinked, if available RP54 9.5.10
-
Headache post in good condition RP54 9.5.8
-
Anti-two blocking device installed and operational RP54 9.2.16 RP54 9.4.8<br>
-
Drilling line in good condition RP9B 3.3.10
-
-
Drawworks properly guarded RP54 9.4.2 RP54 9.6.4<br>
-
Proper lay of drill line on reel RP9B 3.3.10(b)
-
Appropriate lighting installed 1910.307(b)(1)
-
General housekeeping RP54 6.5.1 1910.22(a)(1)<br>
-
Drill floor level
-
Minimum 2 exits from drill floor doghouse
-
Guardrails installed along open edges of drill floor RP54 9.3.17 1910.23(c)(1)<br>
-
First aid kit available in drill floor doghouse 1910.151(b)
11. POWER AND HAND TOOLS
-
Tong snubbing lines in good condition RP54 9.9.6
-
Tong body & jaws in good condition RP54 9.9.7
-
Tong stiff arm available and operational RP54 9.9.4
-
Condition of tong jerk line(s) RP54 9.9.6
-
Condition of hand tools RP54 6.8.6
-
“Iron Roughneck” used
-
IR body & jaws in good condition RP54 9.9.7
-
IR hydraulic system leaks RP54 9.9.9
-
Electric hand tools double insulated or grounded RP54 6.8.7
-
Guards installed on/over all belts, drive chains, gears and drives RP54 6.8.2
-
“Dead man” switch installed on all Electric and Pneumatic tools RP54 6.8.8
12. HOISTING TOOLS, HOOKS, BAILS, ELEVATORS AND OTHER RELATED EQUIPMENT
-
Traveling blocks in good condition RP54 9.7.1
-
Traveling blocks properly guarded RP54 9.7.4
-
Elevators in good condition RP54 9.7.1 RP54 9.7.8<br>
-
Rod hook in good condition RP54 9.7.1
-
Hoisting hook equipped with safety latch or equiv. RP54 9.7.3
-
Crown block assembly secured RP54 9.7.5
-
Transfer elevators in good condition RP54 9.7.1
-
Crew members not permitted to ride traveling block RP54 6.11.1
-
Circulating hose secured to gooseneck and swivel RP54 9.7.7
-
Power swivel secured RP54 9.7.7
-
Hoisting line inspected daily RP54 9.6.1
13. STAIRS, LADDERS, HANDRAILS & GUARDRAILS
-
Adequate stairs provided off rig RP54 9.3.10 1910.24(b)<br>
-
Minimum of 2 stairways to drill floor RP54 9.3.10 1910.36(b)(1)<br>
-
Stairs secured with a pin/keep or nut/bolt/keeper RP54 9.3.8
-
No obstructions RP54 9.3.11
-
Adequate handrails provided on stairs RP54 9.3.8 1910.24(h)<br>
-
Stair treads of uniform size RP54 9.3.9 1910.24(d)<br>
-
Non-skid type stair treads 1910.24(f)