Information

  • Client / Site

undefined

undefined

  • Conducted on

  • Prepared by

  • Location
  • Personnel

Tire Changer

Tire Changer

  • Check to add Tire Changer

  • Tire Changer
  • Bead Breaker pivot is in good condition, showing no excessive wear.

  • Bead Breaker pivot bolts are lubricated with chassis lube.

  • Bead Breaker handle shows no bending or improper repairs and is snug.

  • Air inlet hose is free of cuts, bulges, and leaks.

  • Non-stationary hoses have a pinch clamp.

  • Air line oiler oil level has been checked.

  • Air line dryer has been emptied.

  • Dial pressure gauge located on top of the machine is operational.

  • Air inflation gauge is operational.

  • Inflator has a 3 second pulse when inflating.

  • Table top blaster lines are properly connected.

  • Pop-off valve is in operating condition.

  • Tire changer frame is free of cracks.

  • Table top is snug and free of wobble.

  • Table top is clean and lightly lubricated on the slide areas.

  • Table clamps are in operating condition.

  • Foot pedals are in operating condition.

  • Foot pedal guard is tight and in the correct position.

  • Tire changers are anchored to the floor.

  • Floor around tire changer is clean.

  • Safety inflation line is 24" out and parallel to the machine.

  • Trash can is hung on back of the tool holder/valve stem box for immediate disposal of trash.

  • Valve stem boxes are labeled and stocked.

  • Tools are clean and operational.

  • Robo-arm clamp is at the base of the Robo-arm.

  • Robo-arm shaft stays in the "up" position when raised to the max height.

  • Robo-arm fits are greased on the two pivot ion joints.

  • Transmission lube should be visible on tip of dipstick.

  • Duckhead is tight and free of cracks.

  • Duckhead is slide is lightly greased.

  • Oil injection reservoir fluid is at an acceptable level.

  • Scheduled Maintenance

  • Automatic oiler is filled weekly, as necessary.

  • Oil injector reservoir is filled monthly, as necessary.

  • Transmission has been lubricated monthly, as required.

  • Air gauge calibration check has been done monthly.

  • Comments

Compressor

Compressor

  • Check to add Compressor

  • Compressor
  • Three or four POP-off valves are present and operational. (Depends on store) SchraderAir compressors have 4.

  • Dial pressure gauge is operational.

  • Compressor is set at 150-175 PSI.

  • Wire is snug and hard wired.

  • Hoses are free of kinks, tears, leaks, abrasions, cracks, and excessive wear.

  • Bottom drain is operational and tank is properly drained.

  • Moisture shall be drained daily.

  • Drive belt and guard are in good condition and are free of tears and cracks.

  • Lubrication is at adequate level.

  • Compressors are marked with chalk to identify when last oil and filter change took place.

  • Area around compressor is free from debris.

  • Scheduled Maintenance

  • Pressure relieve valves (functional check) weekly.

  • Air lines have been drained weekly.

  • Tank water build-up has be drained weekly.

  • Oil filter has been changed within 6 months.

  • Drive belt has been inspected within 6 months.

  • Air filter has been changed within 6 months.

  • Tank has been inspected within 12 months.

  • Comments

Balancer

Balancer

  • Check to add Balancer

  • Balancer
  • External cords, terminals, and outlets are free of excessive wear.

  • Outlets are properly installed.

  • Air inlet is connected and hoses are free so excessive wear and leaks.

  • Air dryer is empty.

  • Roller is free of cracks and debris.

  • Table top is in good condition.

  • There are no leaks inside the assembly.

  • Balancer shaft, cones, and wing nuts are oil-free.

  • Cones and balance shaft are free of excessive wear.

  • Cones pass reference gauge test.

  • Balance shaft passes reference gauge test.

  • Calibration is performed monthly.

  • Comments

Lift

Lift

  • Check to add Lift

  • Lift
  • Safety release rod is straight.

  • Cotter pin is present and in good condition.

  • Cylinder cord and hose are free of cracks.

  • Tank reservoir is free of cracks.

  • Reservoir cap is in good condition.

  • External cords are intact and in good condition.

  • Fuel level is acceptable.

  • Cylinder and hoses have no leaks.

  • Scheduled Maintenance

  • Hydraulic fluid has been changed every 12 months.

  • Comments

Torque Wrench

Torque Wrench

  • Check to add Torque Wrench

  • Torque Wrench
  • Check torque wrench calibration daily.

  • Max allowable tolerance is within +\- 7 lbs when wrench is set to 100lbs.

  • Adjustment dial remains stationary during the test.

  • Scheduled Maintenance

  • Precision instrument has been checked for calibration every 2 months.

  • Comments

Floor Jack

Floor Jack

  • Check to add Floor Jack

  • Floor Jack
  • All bolts on the lifting jacks are tight.

  • Air is purged from the jack.

  • Pumps are free of leaks and damage.

  • Jack handle has foam on it and is properly taped.

  • Rubberized grip or tennis ball is present.

  • Hydraulic jack oil is at proper level.

  • All moving parts are lubricated.

  • Floor jack is free of rust and corrosion.

  • Comments

Repair Buffer

Repair Buffer

  • Check to add Repair Buffer

  • Repair Buffer
  • Hose muffler is properly attached.

  • Spring on safety catch is operating correctly.

  • Non-stationary hoses must have a pinch clamp.

  • Comments

Dunk Tank

Dunk Tank

  • Check to add Dunk Tank

  • Dunk Tank
  • Dunk tank has the assigned narrow cylinder nut.

  • Dunk tank has a jamb nut on top of the dunk plate.

  • Non-stationary hoses have a pinch clamp

  • Comments

Impact Wrench

Impact Wrench

  • Check to add Impact Wrench

  • Impact Wrench
  • Impact wrench has proper lubrication.

  • Non-stationary hoses have a pinch clamp.

  • Scheduled Maintenance

  • Impact wrench has been oiled daily.

  • Impact wrench has been greased weekly.

  • Comments

Electrical

Electrical

  • Check to add GFCI Outlet

  • GFCI Outlet
  • Dunk tank area is equipped with GFCI outlet and passes ground fault test.

  • Bathroom area is equipped with GFCI outlet and passes ground fault test.

  • Janitor closet area is equipped with GFCI outlet and passes ground fault test.

  • Hose bib area is equipped with GFCI outlet and passes ground fault test.

  • Check to add Extension Cord

  • Extension Cord
  • Extension cord is in good condition.

  • Extension cord is UL rated.

  • Extension cord is 3 pronged.

  • Extension cord is not a permanent solution.

  • Extension cord is not daisy chained.

  • Extension cord is not powering surge protectors.

  • Breaker Panel / telephone Boards

  • Breaker panel has a cover and is clean.

  • Telephone boards no longer in service need to be de-energized and disposed.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.