Information
-
Line
- Line 1
- Line 2
- Line 4
- Line 6
- Line 7
- Line 12
- Line 13
- Line 14
- Line 15
- Line 16
- Line 17
- Line 18
- Line 19
- Line 20
- Line 21
- Line 22
- Line 23
-
Material:
-
Product Size and SDR
-
Product Type
- PE 80
- PE 100
- ABS
- PLX EVOH
- Vulcathene
- Protectaline
- Excel +
- Enviroline
- Geothermal
-
Colour:
- New Blue
- Blue
- New Yellow
- Yellow
- Grey
- Black
- New Orange
- Orange
-
Coil / Length Number Inspected:
-
Auditor:
- Tim French
- Jana Bujalkova
- Richard Martin
- Sarah Elson
- Paul Alexander
- Darran Fowler
- Robert Kinzer
-
Conducted on:
-
Shift:
- A
- B
- C
- D
-
Team Leader:
- Colin North
- Russ Howe
- Terry Martin
- Mick Thorpe
- Steve Scarborough
-
Operator:
Extruder Set-Up
Extruder Checks
-
Is the image on the scanner within the specified wall thickness tolerance?
Production Paperwork
-
Is a Production Program available and been signed off and dated by Planning and Quality / Technical?
-
Has the following production information been completed?
-
Line Board Information
-
Extrusion Conditions Sheet
-
Conditioned Length Information
-
Has production paperwork been completed correctly and to the correct frequency?
Coiler Set-up
-
If required, has the Coiler been set to the correct caterpillar squeeze, torque and ID settings?
-
If required, has the Coiler Set Up Sheet been completed?
-
If required, has the metre marker been set to 1.000 - 1.010m?
Dimensional Checks
Wall Thickness (mm):
-
Wall Thickness (Specification):
-
Wall Thickness (Measured):
-
Is the wall thickness in tolerance? <br>
Outside Diameter (mm):
-
Outside Diameter (Specification):
-
Outside Diameter (Measured):
-
Is the Outside Diameter in tolerance?
Ovality (mm):
-
Ovality (Specification):
-
Ovality (Measured):
-
Is the Ovality in tolerance? <br>
Flat Spot (mm): Diameters 180mm to 355mm inclusive
-
Flat Spot (Specification):
-
Flat Spot (Measured):
-
Is the Flat Spot in tolerance? <br>
Length (m):
-
Length (Specification):
-
Length (Measured):
-
Is the Length in tolerance? <br>
Inspection Frequency
-
Is the inspection frequency correct for all measured items (including flat spot measurements, coiled ovality and metre marking checks)?
Temperature at Saw (or Coiler):
-
Temperature (Specification):
-
Temperature (Measured):
-
Is the Pipe temperature within the specified limits? <br>
Appearance
Visual Inspection:
-
Check for the following:
-
Correct Operator Inspection frequency
-
Scratches / Gouges / Tool Marks
-
Contamination in Pipe bore
-
Pipe Colour
-
Foil Appearance
-
Core Pipe Appearance (Protectaline Only)
-
Surface Contamination
-
Splits / Pin Holes
-
Is the visual appearance of the pipe acceptable?
-
Does the pipe have the correct markings as per the program and are these clearly legible?
-
Is the correct colour hot foil (Medec) marking being used?
-
Does the pipe have the correct shift code?
-
Is the pipe correctly labelled with the length number using a permanent marker?
Packaging and Storage
Packaging
-
Have the pipe ends been sealed with end caps or bags (when applicable)?<br>
-
Has the correct packaging been used (e.g. woods, strapping and security banding)?
-
Are the bundles (or coils) identified with the correct labels and tape?
Storage
-
Has finished product been stored correctly (e.g. Coils on matting)?
QC Requirements
Pipe Samples
-
Have the correct number of Pipe samples been submitted to the QC Laboratory?
-
Are these samples correctly labelled and the dimensions within specification?
Calibration
-
Are Micrometers and Pi Tapes calibrated, with the owners name and coloured sticker clearly visible?
Reject Material
-
Is reject product clearly identified (with reject tape / Material ID tape) and cut back to the correct length?
Audit Review
Audit Non-Conformities Identified
-
Non-Conformities Below
-
Description of Non-Conformity
-
Photograph of Non-conformity
-
Action Taken
-
Responsibility
- Colin North
- Russ Howe
- Terry Martin
- Mick Thorpe
- Steve Scarborough
-
Date Completed
Audit Review Signatures
Operator:
-
Signature:
-
Date:
Team Leader:
-
Signature:
-
Date: