Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location

Solar with Wind Turbine

SITE OVERVIEW

  • Road/Roads leading up to the tower

  • Full site overview from the ground

  • All angles of the fence from the ground

  • Area around all the stay wires

  • Other Images

  • Comments

BATTERY BOX

  • Entire outside of the battery box, All angles are to be included

  • Entire inside of the battery box, All angles are to be included

  • All bosal leading to the tower. If the bosals are concreted, include imagery of it

  • All batteries. Indicate the 3 link system

  • Battery dates

  • Are the individual battery voltages the same?

  • Are the draws between the battery leads the same?

  • Is the voltage on the batteries the same as the App?

  • If No to above question, specify the difference

  • What is the draw to the equipment from the batteries

  • Other Images

  • Comments

SOLAR PANNELS

  • Overview of all the solar panels. No zoomed in Images

  • Is the wattage size correct according to the site equipment sheet?

  • Are there any negative draws of negative input voltages on the panels?

  • Other Images

  • Comments

CHARGER/CONTROLLER

  • Charger/Controller type

  • Is the charger unit set corretly

  • Is the QR code available and scanned (Victron)

  • Other Images

  • Comments

EQUIPMENT BOARD/BOX

  • Exterior of box/boxes

  • Interior of the box/board. Ensure all equipment is visible

  • What is the average amp draw between the incoming power and the all the equipment? Specify highest

  • What is the average voltage loss between the incoming voltage and the power supplies? Specify highest

  • Is the output voltage on the camera power supplies set to between 27.5V and

  • Are the equipment serial numbers and/QR code numbers correct according to the site equipment sheet?

  • Are the relays working correctly

  • Has the VPU QR code been scanned correctly

  • Other Images

  • Comments

CAMERA

  • Is the serial number and QR code correct according to the site equipment list?

  • What is the camera draw?

  • Image of the camera camera

  • Image of the camera pedestal

  • Has the QR code been scanned

  • Other Images

  • Comments

LINKS

  • All link rockets

  • All links secured tightly?

  • Are all links working and have good signal Other

  • Other Images

  • Comments

SECURITY CAMERA

  • Image of the security camera

  • Is the security camera lens cleaned, positioned correctly and above 3m?

  • Other Images

  • Comments

WEATHER STATION

  • Image of the weather station display screen, anemometer and station

  • Has the weather station been calibrated correctly? (Longitude, Latitude, Elevation, Time, Date, Board rate, Cup size, etc)

  • Has the station solar panel being cleaned

  • Is the Rain collector area clean and clear

  • Has the anemometer being serviced? (Cup and direction indicator removed, bearings cleaned and positioned back correctly)

  • Are the weather station unit and anemometer, just above the tree line and facing North?

  • Other Images

  • Comments

LATTICE AST

  • Are the nuts and bolts in good condition?

  • Random imagery of nuts of bolts on the tower, minimum 3 section

  • Are the stay wire points on the tower in good condition?

  • If No to above, please specify and attach images to other question below

  • Imagery of the base of the tower

  • Is there a fall arrest installed

  • Are the aircraft/navigation lights fitted and working?

  • Other Images

  • Comments

MAN LOOKOUT

  • Are the nuts, bolts and ladders in good condition?

  • If No to above, please specify and attach imagery to other question below

  • Random imagery of nuts of bolts on the tower, minimum 3 section

  • Imagery of the tap doors, include the hinges and locking mechanism

  • Imagery of the Cabin area and Roof

  • Are the stay wire points on the tower in good condition?

  • If No above question, please specify and include imagery in other question below

  • Imagery to the base of the tower

  • Other Images

  • Comments

ANODES

  • Are the anodes functioning correctly?

  • Images of all the anodes

  • Other Imaegs

  • Comments

EARTHING

  • Is there a suppressor for each equipment on the Tower? (Cameras, Links, etc.)

  • Are the suppressors, camera pedestal, link brackets and Tower equipment box earthed to a single point on the tower, which is at least 2m below the last link?

  • Is the Lighting/earth spike at least 3m above the top of the camera?

  • Is the equipment in the equipment box earthed to a single point in the box, which when has an external point that goes down to the same point (single point) as the other equipment? *

  • Has all earth cable connections point being cleaned, i.e. metal making contact to metal?

  • Has the lightning rod/spike tips, being cleaned to expose the metal better?

  • Also is it free of rust?

  • Does all tower bases have earth straps/cables going into the ground?

  • Are all stay wires earthed to the ground?

  • Are all battery boxes earthed to the ground with an earth rod?

  • Attach images for all above mentioned points (Suppressors, brackets, camera pedestal, equipment box, earth point on tower, tower base earthing, stay wire earthing and battery box earthing)

  • Other Images

  • Comments

Overall

  • Comments

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.