Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
General Employee Safety
-
Work boots worn
-
Work gloves worn
-
Appropriate work clothes worn
-
Hard Hats worn
-
High viz vest worn
-
Safety glasses worn
-
Has the Job-site AHA being filled out
-
Knees bent when lifting
Pole Inspection
-
Black line on pole no more than 6 inches above grade
-
Hole back filled so that pole stands upright and moves only slightly when leaned on
-
Dirt mounted 6 inches around base of pole
Electrical Installation/Testing
-
All the correct tools being used
-
Are all the correct Arc Flash PPE being worn according to the NEC & NFPA regulations, CAT 2 CAL 8.2
-
Arc Flash boundaries being adhered to according to the NFPA regulations
Picking Up Poles
-
Pulley system used when dropping the wire
-
Pole lifted straight and walked out of the hole
-
Is the pole being gradually lowered
-
Hole backed filled
-
Pole carried on employees shoulders to the truck
-
Has the Equipment or Property been inspected for damages
Service Pole
-
Tac-On can at chest level
-
Straps attached at 18" above can, 18" below top of conduit and in middle
-
Plug & breakers correctly marked & labeled
-
Tac-On can secured to the pole
Meters / Ground Rods
-
Ground rod pounded to grade
-
Ground rod attached to ground wire
-
Ground rod within distance per code of meter
-
Meter trench meets code specification of area
Cords and Boxes
-
Has the job-site been inspected for cords that run across roadways or high traffic pedestrian areas
-
Are cord ramps being used
Ladder Safety
-
V-bracket in good condition
-
Moving parts in good working order
-
Both ladder feet are being used properly and completely on the surface
-
Ladder set at a 4:1 ratio
-
Ladder fiberglass splinter free and no cracks
-
All manufacturers stickers visible
-
Ladder strap being used
-
All rungs free from damage
Wiring Poles
-
Pulley System being used
-
Power turned off (Lock-Out Tag-Out)
-
Wedge clamp attached to ground wire
-
J-hook facing away from wire source when finished pulling wire
-
Each pole has a 3' loop of wire at the top of the pole
-
Splices are at the side of the loop
-
Wire is hung in a consist and uniform manner
-
Drop spans and riser cords are properly strapped (3 straps)
-
No gaps behind the pole after wiring
-
Positioning device being used when on the 3rd rung
De-Wiring
-
Wire lowered with the pulley system
-
Kearny's untapped rather than cut
-
Kearny's and wedge clamps removed from wire before being rolled up
-
Wired taped at two ends and in the middle when rolled up
Boosters
-
Boosters hung on bracket
-
Boosters secure with 3 nails
-
After removal of boosters, nails removed
-
Boosters are raised with the pulley
Phone Line
-
Phone line (based on type) hung underneath power lines
-
Extra phone line coiled near source and near trailer
-
No mid air splices
-
Splices are at chest level of pole
Jobsite
-
All extra Power Plus equipment or materials picked up from site
-
Power Plus logos on poles and visible from the street
-
All holes back filled as necessary
-
Open trenches properly secure per OSHA standards (29 CFR 1926 Subpart P) 1926.651(C)
Additional information
-
Add signature