Title Page

  • Site conducted

  • Job address :
  • Building Description :

  • Completed By :

  • Completed On :

1.0 Ground Floor Frames

  • 1.1 - Bottom plates are fixed down at 900mm centres

  • 1.2 - All noggins are installed

  • 1.3 - Corners have been nailed off / Straightened

  • 1.4 - Double studs installed under load points

  • 1.5 - Ply braces installed as per RBRT Plans

  • 1.51 - Bolts installed where ply braces can't be installed

  • 1.6 - Ply brace bolts have been tightened

  • 1.61 - Double ply brace rods have been installed

  • 1.7 - Ceiling blocks installed

  • 1.71 - Thruss blocks installed

  • 1.8 - L brackets installed no more than 1200mm centres

  • 1.9 - Joist hangers installed

  • 1.10 - Beam connection brackets installed as per dindas design

  • 1.11 - Patio / Alfresco posts installed

  • 1.12 - Rods connected and tightened

  • 1.13 - Pole plates fixed as per engineer's design / RBRT design

  • 1.14 - Power truss braces installed as per manufacturers specs

  • 1.15 - Steel works complete

  • 1.16 - Lower roofs installed

  • 1.17 - Roof tie down complete

  • 1.18 - Speed braces installed

  • 1.19 - Under floor system TS (tensioned strap) brace installed / tightened

  • 1.20 - Structural grout installed where needed

2.0 Fire Walls

  • 2.1 - Bottom J track has been sealed

  • 2.2 - Fire check sheets are tight

  • 2.3 - Brackets have been fixed off at no more then 3.0m centres

  • 2.31 - Brackets are installed to every H Stud

  • 2.4 - Enough clearance on shaft liner to stud wall

  • 2.5 - Left over materials stored and covered in plastic

  • 2.6 - Cantilever shaft liner section has brackets installed

3.0 1st Floor Frames

  • 3.1 - Bottom plates are fixed down at 900mm centres

  • 3.2 - All noggins are installed

  • 3.3 - Corners have been nailed off / Straightened

  • 3.4 - Double studs installed under load points

  • 3.5 - Ply braces installed as per RBRT Plans

  • 3.51 - Bolts installed where ply braces can't be installed

  • 3.6 - Ply brace bolts have been tightened

  • 3.61 - Double ply brace rods have been installed

  • 3.7 - Ceiling blocks installed

  • 3.71 - Thruss blocks installed

  • 3.8 - L brackets installed no more than 1200mm centres

  • 3.9 - Joist hangers installed

  • 3.10 - Beam connection brackets installed as per dindas design

  • 3.11 - Patio / Alfresco posts installed

  • 3.12 - Rods connected and tightened

  • 3.13 - Pole plates fixed as per engineer's design / RBRT design

  • 3.14 - Power truss braces installed as per manufacturers specs

  • 3.15 - Steel works complete

  • 3.19 - Under floor system TS (tensioned strap) brace installed / tightened

4.0 2nd Floor Frames

  • 4.1 - Bottom plates are fixed down at 900mm centres

  • 4.2 - All noggins are installed

  • 4.3 - Corners have been nailed off / Straightened

  • 4.4 - Double studs installed under load points

  • 4.5 - Ply braces installed as per RBRT Plans

  • 4.51 - Bolts installed where ply braces can't be installed

  • 4.6 - Ply brace bolts have been tightened

  • 4.61 - Double ply brace rods have been installed

  • 4.7 - Ceiling blocks installed

  • 4.71 - Thruss blocks installed

  • 4.8 - L brackets installed no more than 1200mm centres

  • 4.11 - Patio / Alfresco posts installed

  • 4.12 - Rods connected and tightened

  • 4.13 - Pole plates fixed as per engineer's design / RBRT design

  • 4.14 - Power truss braces installed as per manufacturers specs

  • 4.15 - Steel works complete

5.0 Roof

  • 5.1 - All trusses installed

  • 5.2 - All rafters installed

  • 5.3 - Tie down installed as per roof design / check plan

  • 5.4 - Binders installed / strapped where needed

  • 5.5 - speed brace installed

  • 5.6 - Have you checked roof is ready for fascia/ gutter

  • 5.7 - Valley boards installed

6.0 Office

  • Is this building/ Unit ready for frame inspection

  • Is there Outr fire wall systems to be installed ?

  • Has Builder been notified so they can advise roofing company

  • 7.0 Defect Items:
The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.