Gas Safety Audit
-
Work Type being carried out?
-
Fuel Type?
-
Work Location?
-
Do you receive and read Gas Installer?
-
Are you aware of Watkins Technical Bulletins regarding Gas?
-
Do you read and retain them?
-
Please give an example...
-
What Gas reference information do you carry with you?
- domestic gas safety
- technical bulletins
- manufactures lnstructions
- unsafe situations
- warning notices / Lables
- Nothing
- out of date
-
Are you aware and have a copy of Watkins Gas Operatives Manual which describes Watkins policies and procedures when caring out work on Gas?
-
Tool box talk given on Watkins Gas Operatives Manual..
-
I been issued and understand the policies and procedures as described within the Watkins Gas Operatives Manual
-
Print name
-
Signature
-
Issue date
Equipment
-
Equipment carried
- Manometer
- Flue Gas Analyser
- Gas Sniffer
- earth bonding clamps
- stopwatch
- leak detection fluid
- Heat Mat
- Fire extinguisher
- Warning Lables
- Warning notices
Operative Assessment
-
Installation of Gas Pipe work and Fittings
-
Can compression fittings be used in inaccessible locations?
- yes
- No
- On Site training
-
Pipework installed on a brick and block wall behind a dot and dab plasterboard, how would you protect the void between the plasterboard and brick and block from a potential gas escape?
- continuos adhesive dabs to surround pipework
- prompting
- on site training
-
What materials can be used when sleeving gas pipework and what should also be considered when choosing the selected material?
- any material that is capable of containing or distributing gas
- considering mixed metals and corrosion by electrolysis
- prompting
- on site training
-
When running pipework within a protected shaft, what materials can be used?
- continuous length of copper
- Screwed steel
- CSST
- prompting
- on site training
-
If the pipework within the protected shaft is boxed in what now should be considered?
- ventilation as a void has been introduced
- fire rating of the boxing
- copper tube can be used
- prompting
- on site training
-
How far away should a gas pipe be positioned from an electricity cable?
- 25mm
- prompting
- on site training
- 150mm
-
How far away should a gas pipe be away from a fused spur, consumer unit ?
-
SCENARIO, when carrying out a gas carcass in copper tube that is to be laid in a screeded floor, please explain the installation and testing procedures.
-
Read the provided technical drawing showing gas pipe routes and sizes
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Sleeve the gas pipe through the cavity
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Test the pipework before protection is applied
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Carry out tightness test with air
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
No permissible drop is allowed
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Record the test results on a test certificate
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Cap all open ends with an appropriate fitting
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
SCENARIO, A new plot has already been filled with the electricity on and the gas meter connected but capped off.
-
First action is to Walk the job
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Visual checks of the boiler,flue and any other gas appliances
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Check any other Gas points
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Visual check of the gas meter box, sleeving, Earth Bonding etc,
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
The gas meter is capped, please describe how you would re connect the meter?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Describe a let by test
-
7-10mb for 1 min
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
If a let by occurs what would be at fault?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Who would you contact if an ECV was letting by?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Describe a Tightness test
-
1 min stabilisation at 20 mb, raised back to 20 mb if any drop occurs
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
2 min test at 20 mb
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
If a tightness test failed on a new system what would be the permissible drop?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Describe a purging procedure
-
Ventilate the property
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
No naked flames, do not operate electrical switches
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Warn others within the property that purging is taking place
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Can we purge a domestic gas installation that exceeds 0.035 of pipework and fittings volume?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Fire Boiler
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Working pressure
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Does the engineer under stand that the working meter gas pressure should be + or - 2mb of the the set regulator pressure?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Does the engineer understand that with the system working at maximum rate, that between the meter and each appliance there should be no greater than a 1 mb drop ?
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Explain how to gas rate an appliance
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Run appliance at its maximum, Take 1st meter reading, time for two mins, take second reading, take one from the other multiply by 30 then times 10.72 which will give you the rated KW input of that appliance. This figure should be within + or - 5% of stated manufactures data.
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Flue Gas analysis
- Excellent
- Good
- Prompting
- On site training
- In Depth training
- Install earth bonding clamps
- remove disc from the meter
- re instate meter
- ECV
- gas transporter
- 4mb
- zero mb
- yes
- no
-
Visual inspection of work,
-
Add media
-
Standard of work/Faults
-
Gas test question paper given
-
Score
- Pass
- Fail
- Excelent
- Good
- Prompting
- on site training
- in depth training
- NA
-
Using the Gas industry unsafe situations procedure can the engineer identify unsafe situations?
Conclusion/Recomendations
-
Conclusion / Recomendation